Using the Composite Railway-Insulator Tester & Software
32
5.1.7 Get (Firmware) Revision of the Probe
Select
Get Revision of Probe
to receive the Insulator Tester’s internal Firmware Revision level.
Normally, this function is used by Positron Technical Support when troubleshooting the
Insulator Tester. In this instance, the function is used as a confirmation that the Tablet/Laptop
can communicate a command to the Insulator Tester and that the Insulator Tester will respond
via the long range Bluetooth communication through the associated COM Port.
Once you have selected
Get Revision of Probe,
communication between the Tablet and
Insulator Tester is established. Ensure that the Probe is in
Awake Mode
by pressing the push
button of the Insulator Tester Probe. See Figure 11. If required, select
BEEP
after the Probe
is
awakened. The Probe will respond with a BEEP tone.
This step verifies that the Tablet/Laptop can communicate with the Probe. Once Bluetooth
connectivity and functional communication are verified, the Probe can be switched off after
pressing the Close button. The Probe will be switched on again in the field when scanning is to
begin.
Before going out into the field for an insulator scanning session, ensure the Positron Insulator
Tester and Tablet/Laptop are fully charged. The batteries of the Tablet/Laptop are best
maintained for longer life by recharging before the battery charge depletes below 50%.
N
OTE
Figure 11
C-Tester V2.0 60Hz
Example Only
Содержание 3782101C/50
Страница 2: ......
Страница 4: ......
Страница 7: ...1 Chapter 1 General Information ...
Страница 8: ...General Information 2 ...
Страница 11: ...5 Chapter 2 Overview ...
Страница 12: ...Overview 6 ...
Страница 17: ...11 Chapter 3 Composite Insulator Tester Elements ...
Страница 18: ...Composite Insulator Tester Elements 12 ...
Страница 24: ...18 ...
Страница 25: ...19 Chapter 4 Windows Based Software ...
Страница 26: ...Windows Based Software 20 ...
Страница 29: ...23 Chapter 5 Using the Composite Insulator Tester Software ...
Страница 30: ...Using the Composite Railway Insulator Tester Software 24 ...
Страница 54: ...48 ...
Страница 55: ...49 Chapter 6 Interpreting Graphic Results Electric Railway Application ...
Страница 56: ...Interpreting Graphic Results Electric Railway Applications 50 ...
Страница 64: ...58 ...
Страница 65: ...59 Chapter 7 Specifications ...
Страница 66: ...Specifications 60 ...
Страница 68: ...62 ...
Страница 69: ...63 Chapter 8 Important Information ...
Страница 70: ...Important Information 64 ...