Now, turn the adjustable stand assembly back to normal orientation 

and arrange all cables to come out of the area for mounting main unit from the 
bottom edge for ease of later operation. 

PREPARING THE MAIN UNIT 

On the back of the main unit, there is a service window among the 4 

matching pegs. Remove the service window lock screw to find several jumpers. 
The jumpers in this window are designated for VGA port and COM port power 
supply function. Please consult your dealer for technical support on setup of 
these jumpers.  Please note that  only those qualified 
technicians may adjust in the service window with 
information from Posiflex and  the contents in the 
service window may change  without notice  as time 
develops. 

 
 
 

SIDE MOUNT UPGRADE KIT 

Remove the 2 circled screws in last picture above 

to remove the cover for side mount upgrade kit. Take out 
the cable inside this cover as circled in right picture and 
remove the 2 shorting jumpers inside and then connect it to 
connector inside  the side mount upgrade kit like SD400  as 
arrowed in same picture. Gently arrange the excessive 
length of this cable back in the hole and screw-fit it back to 
the position originally occupied by the cover. Please reserve the cover if there 
is chance to have the side mount kit removed in the future. 

DESKTOP MOUNTING

KS6115:258~355

 

 
 
 
 
 
 
 
 
 
Match the matching pegs on the back of the main unit against the 

matching holes on the stand assembly. First aim the matching pegs toward the 
upper round part of the hole and make sure that all pegs are inside the holes. 

Matching Holes 

Matching Pegs 

Round Part 

Slot Part 

Service Window 
Lock Screw 

Jumpers 

Содержание KS-6315

Страница 1: ...or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware conc...

Страница 2: ...improper maintenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you are going to re power on the system Replace the battery as soon...

Страница 3: ... memory card connector 2 one IDE connector and HDD power connector for HDD in base SD500 covering options of USB interface WiFi and Audio ports Bar code card reader BC 300U Side Views KS 6317 7 3 4 1 1 KS 6315U KS 6315 KS 6315U 4 5 6 9 8 8 9 10 10 7 5 2 2 1 1 12 13 KS 6317 KS 6315U 11 11 10 10 7 5 KS 6315 14 15 16 7 1 ...

Страница 4: ...tand 8 Cable cover 9 Removal hollow in cable cover 10 Lock release lever for tilt angle adjust 11 Lock release button for main unit detach 12 Touch open cover 13 Power switch 14 Brightness adjust thumb wheel 15 Touch open door latch 16 PS 2 KB port 17 Rear connect cover 18 Power connector hole 19 Cable exit 1 1 KS 6317 KS 6315U 8 8 7 5 19 19 17 17 18 19 19 Slim Base Universal Base 20 20 21 21 22 2...

Страница 5: ...g power adaptor housing optional UPS battery storage for both desktop and wall mount applications e Support WinCE Win 2000 Win XP Pro WEPOS and Linux environment f High quality 15 TFT active matrix LCD panel for KS 6315 High quality 17 TFT active matrix LCD panel for KS 6317 g Brightness control by either software or hardware h Vertical type LCD panel with easy tilt angle adjustment from 17 5 to 7...

Страница 6: ...on by alarm clock or COM port MODEM ring or LAN Option Items Note The underlined items in the following list means that option must be set prior to shipment from the factory The rest items can be set by the dealers a DDR SDRAM memory expansion up to 1GB b RS232 interface Infra Red type touch panel durable for 50 million touches min at same spot c 2 HDD installation or CF memory card reader slot d ...

Страница 7: ...ible then Please first note orientations of every existing cable connection and then disconnect every cable properly before separating the main unit from the adjustable stand assembly Please note that the click lock spring has to be pressed down prior to pulling out the connector such as the LAN port Please also note that the fixing screws have to be loosened free prior to disconnection such as th...

Страница 8: ...om plate up and the inside of an example slim base model looks like this in the above right picture The inside of an example universal base model will look like the picture on next page Both with numbered items listed on next page However there could be some variation to the contents inside depending on what option items actually installed Bottom Plate Fixing Screw Push Bottom Plate This Way To Op...

Страница 9: ... strap through the 2 standing slits on base box to fix the battery in position firmly Route the battery connection cable through appropriate passage to the battery connector on the main unit Please remove the UPS battery bracket fixing screw and slide right the UPS battery bracket to take it out for universal base model as in left picture Put the battery in at the other end first and remount the b...

Страница 10: ...ase the base box from the base stand by removing the 3 screws as arrowed in the left picture for slim base model or by removing the 3 screws arrowed in the right picture for universal base model Release the cable tie and reroute all cables through the cable passage to main unit for wall mount application and through the cable exit to external connections Hook the base box onto the bottom plate now...

Страница 11: ...f restrictions must be taken before decision to install a base mount upgrade kit to these models To remove the rear connect cover in slim base please refer to the inside view of the base unit at right and use a flat head screwdriver to pick the plastic hook plate of the rear connect cover from inside behind the UPS battery The rear connect cover of universal base can be removed by pushing the plas...

Страница 12: ...ime develops SIDE MOUNT UPGRADE KIT Remove the 2 circled screws in last picture above to remove the cover for side mount upgrade kit Take out the cable inside this cover as circled in right picture and remove the 2 shorting jumpers inside and then connect it to connector inside the side mount upgrade kit like SD400 as arrowed in same picture Gently arrange the excessive length of this cable back i...

Страница 13: ...connectors like the LAN connector have to be gently inserted until a click is heard It is recommended that connectors such as the external VGA and LPT connector be screwed into place once seated The 2 COM ports are of 10 pin RJ45 format and the DB9 to RJ45 conversion cables in accessories should be used for regular RS232 cable to connect through Adjust the slack of each cable and close the cable c...

Страница 14: ...D Please use the recovery CD in rescue operation only Using it otherwise may wipe out whatever stored in the HDD All upgrade devices drivers needed for manual installation in usual way are available in the subfolder drivers in OS recovered HDD and the latest versions of these required drivers will be available on our web http www posiflex com tw Then follow instructions from your system integrator...

Страница 15: ...1 2 hours every month for temperature over 30 C Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work The UPS battery can support basically the data preservation and smooth running of the system during intermittent or few minutes 15 30 min depending on loading and battery condition power failure Batter...

Страница 16: ...er operation The power cable the power outlet and any power fusing arrangements must conform to local safety regulations Please never do any connection disconnection when system is still powered on Please always keep the external power adaptor in a free air circulation POWER ON OFF Touch Open Cover A gentle tap on the touch open cover at left side of the main unit will open the cover and show the ...

Страница 17: ...sed causing trouble for system restart or even this forced power off please disconnect the UPS battery if installed and the AC power supply for few minutes This may allow all hardware registers to reset This switch can also be programmed as an ON only switch That means if the application program issues a command compliant with the KS series technical manual this switch will always turn the system ...

Страница 18: ...ystem is improperly turned off before a complete boot up procedure the above preset power on control functions will be disabled until next turning off after a complete boot up DISPLAY ISSUES Main LCD Display For best viewing result please set your display resolution at 1024 x 768 with high color for KS 6315 and set it at 1280 x 1024 with high color for KS 6317 In configuration of system memory max...

Страница 19: ...nserted in the line output jack TOUCH PANEL All paragraphs below are applicable for models with touch panel only The user of those models without touch panel can ignore them and consider this user s manual ends here Mouse Emulation The touch panel in KS system uses USB interface as standard Only the optional InfraRed type touch panel of KS 6315 uses RS232 interface When the touch driver is properl...

Страница 20: ...be covered in the connection area Removal of this cover will void the product warranty Once the RS232 touch controller driver is installed the user can utilize it to control the mouse emulation Please click Start Settings Control Panel and Elo Touchscreen or just click the elo icon in tool tray to engage this utility However with this touch controller driver certain display mode like full screen d...