Part 11

DESKTOP MOUNTING

KS6115:258~355

 

 
 
 
 
 
 
 
 
 
Match the matching pegs on the back of the main unit against the 

matching holes on the stand assembly. First aim the matching pegs toward the 
upper round part of the hole and make sure that all pegs are inside the holes. 
Then slide the main unit down to move the pegs into the lower slot part of the 
holes till it clicks. Note that all the cables come out of the stand from the lower 
edge and won’t get trapped by this mounting operation. If later on you want to 
remove the main unit from the stand, you’ll have to press down the 
lock/release button on back of the stand at the time lifting the main unit. 

For desk top/counter application, the body of KS-6115 occupies a 

space of 381 mm wide, 265 mm deep and 258 to 355 mm high per main unit 
tilt angle. The minimum height of above models shall be increased by about 
4.5 mm if InfraRed type touch panel is used.

KS-6115U:294.5~391.5

 

CONNECTING CABLES 

To re-assemble the main unit with stand assembly for operation, 

please connect all required cables to the appropriate connectors. Please make 
sure that each connector is connected to the  correct port with the correct 
orientation. 

Damages due to incorrect connection or orientation are not 

covered by product warranty!

 

Some connectors like the LAN connector have to be gently inserted 

until a click is heard. It is recommended that connectors such as the external 
VGA, COM and LPT connector be screwed into place once seated. 

Adjust the slack of each cable and close the cable cover. Re-adjust the 

tilt angle of the screen for best viewing. 

Connect the cables to appropriate external devices through the cable 

exit at the bottom of stand assembly. Please make sure that each connector has 
to be connected to the right device in the right way. 

CAUTION: On doing any insertion or extraction of any connector, please 

always hold the connector head itself instead of pulling on the 
cable wire. Failure to do this could damage the cable and jack 
that is considered as an artificial destruction and is not 
covered by the warranty.

 

Matching Holes 

Matching Pegs  

Round Part 

Slot Part 

Содержание KS-6115

Страница 1: ... of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hard...

Страница 2: ...ed batteries and always replace only with battery of same type DAILY MAINTENANCE GUIDE For regular cleaning of the KS systems please use only soft haired brush or dry soft cloth You may use moist soft cloth to remove stains when necessary Apply only proper amount of mild neutral detergent for obstinate stains Please note that never use Acryl dissolving solvent or Polycarbonate dissolving solvent Y...

Страница 3: ...ear View Bottom View PARTS IDENTIFICATION 1 Main unit 2 Touch panel LCD panel 3 Optional side mount kit e g SD 400 4 Power indicator 5 Slim base stand 6 Cable cover 7 Removal hollow in cable cover 5 3 4 1 1 4 6 7 2 2 14 1 11 13 9 12 8 5 10 1 16 6 17 8 16 18 15 19 ...

Страница 4: ... mount application and easy wall mount conversion storage room for 3 5 HDD and optional UPS battery for both desktop and wall mount applications e Support WinCE Win XP Pro WEPOS and Linux environment f High quality 15 TFT active matrix LCD panel g Brightness control by hardware h Vertical type LCD panel with easy tilt angle adjustment from 15 to 75 i Durable resistive type leading edge Infra Red t...

Страница 5: ... power off protection The power switch is safely located inside a push open cover s Preconditioned power up function by alarm clock or COM port MODEM ring or LAN Option Items Note The underlined items in the following list means that option must be set prior to shipment from the factory The rest items can be set by the dealers a DDR SDRAM memory expansion up to 1GB b Integrated side mount upgrade ...

Страница 6: ...essible then Please first note orientations of every existing cable connection and then disconnect every cable properly before separating the main unit from the adjustable stand assembly Please note that the click lock spring has to be pressed down prior to pulling out the connector such as the LAN port Please also note that the fixing screws have to be loosened free prior to disconnection such as...

Страница 7: ...s in left picture below for slim base to open The inside will look like the right picture below with each numbered items described further below However there could be some variation to the contents inside depending on what option items actually installed 1 Cable Exit For External Connections 2 Base Box Screw 3 Cable tie Step A Prepare a soft clean flatsurface such as a piece of cloth on the desk ...

Страница 8: ...is terminal according to the wall material Drywall concrete solid wood etc Consult with your contractor if it is necessary A fully equipped system may weigh up to 8 kg or 18 lbs Take the separated bottom plate and remove the 4 rubber feet to work as the wall mount bracket Fix this bracket to wall at the 3 arrowed holes for slim base model as in the above left picture with proper materials and prop...

Страница 9: ...of such kind of restrictions must be taken before decision to install a base mount upgrade kit To remove the rear connect cover in slim base please refer to the inside view of the base unit at right and use a flat head screwdriver to pick the plastic hook plate of the rear connect cover from inside behind the area with Velcro strap 12 2nd LCD Panel Or Customer Display Fit the joint base of PD 2501...

Страница 10: ... to find several jumpers The jumpers in this window are designated for VGA port and COM port power supply function Please consult your dealer for technical support on setup of these jumpers Please note that only those qualified technicians may adjust in the service window with information from Posiflex and the contents in the service window may change without notice as time develops SIDE MOUNT UPG...

Страница 11: ...e the main unit with stand assembly for operation please connect all required cables to the appropriate connectors Please make sure that each connector is connected to the correct port with the correct orientation Damages due to incorrect connection or orientation are not covered by product warranty Some connectors like the LAN connector have to be gently inserted until a click is heard It is reco...

Страница 12: ... recovered A Posiflex supplied USB interface CDROM drive will be required for such action Other brand CDROM drive may require its specific driver different from what supported in the recovery CD Please use the recovery CD in rescue operation only Using it otherwise may wipe out whatever stored in the HDD All upgrade devices drivers needed for manual installation in usual way are available in the s...

Страница 13: ... supply for proper operation The power cable the power outlet and any power fusing arrangements must conform to local safety regulations Please never do any connection disconnection when system is still powered on Please always keep the external power adaptor in a free air circulation POWER ON OFF Touch Open Cover A gentle tap on the touch open cover at left side of the main unit will open the cov...

Страница 14: ...ons such as Modem Ring Up and Alarm Clock Wake Up or LAN Wake Up To utilize Modem Ring Up or Alarm Clock Wake Up function the user should enter the CMOS setup by pressing Del key at system boot up choose for PM Wake Up Events in Power Management Setup and make the Ring Power Up Control enabled for Modem Ring Up or select the Power Up by Alarm for Alarm Clock Wake Up Save the configuration and exit...

Страница 15: ...CUSTOMER DISPLAY Please follow the instructions on the manual that comes along with the customer display PD 2501 or PD 2602 when it is installed SERIAL PORTS COM1 2 In KS system there are 2 serial ports available Both serial ports can supply a 5 V DC through pin 9 after proper jumper setting change Both ports are standard RS232 serial ports as status at delivery For models using RS232 interface to...

Страница 16: ...icking on the right button of a mouse touching any point on the screen surface after touching the right click sticky button results as a click on the right button of the mouse at that point Posiflex USB Touch Manager A program named Posiflex USB Touch Manager and a right click sticky button tool in the program group Posiflex USB Touch Tools is installed in the preloaded Windows system with a USB i...

Страница 17: ...al Manager and a right click sticky button tool in the program group Posiflex Tools is installed in the preloaded Windows system with a PS 2 interface touch panel controller This program can also be obtained by download from the POSIFLEX web site ...

Страница 18: ...Part 18 ...

Страница 19: ...Part 19 ...

Страница 20: ...Part 20 警告使用者 這是甲類的資訊產品 在居住的環 境中使用時 可能會造成射頻干 擾 在這種情況下 使用者會被要 求採取某些適當的對策 T31454 ...