6.
Close
the valve on the Poseidon EBS
7.
Release
the pressure by using the purge button on the 2nd stage.
8.
Unscrew
the filling adapter/hose from the Poseidon EBS.
9.
Mount
the blanking plug in to the 7/16” HP port of the 1st stage and make sure
it’s
firmly attached
. Before mounting the blanking plug,
inspect the o-ring
to
make sure it’s without any flaws, make sure the o-ring is
lubricated
and that all
sealing surfaces are
clean and undamaged
.
10. Open the valve
[1]
on the Poseidon EBS and check the pressure. If pressure is
150 bar/ 2176 psi
[2]
it’s
OK to use
. If the pressure is below 150 bar / 2176 psi,
start the filling procedure from
pos 1 on page 4
.
2.