background image

Poseidon EBS MkII / Sea Air EBS MkII Manual

Page 4

S.A.R

S.A.R

Filling instructions

 

If the pressure is 

200 bar or more

 - go to position 

11

 on page 

6

.

Recomended filling pressure is 

200 bar/ 2900 psi

.

Maximum

 filling pressure is 

232 bar/ 3364 psi.

 

Use Poseidon filling adapter art no 0800-015.

2. 

Remove the blanking plug

 from the 1st stage.

    Inspect the O-ring and attach the filling adapter to the 7/16” HP port where the  

    blanking plug was mounted. Make sure the filling adapter is 

firmly attached

.

    Attach the filling hose to the G5/8” thread on the filling adapter.

3. 

When the filling hose is 

firmly attached

 to the filling adapter, slowly 

open

 the  

    valve on the 1st stage by turning the valve handle 

counter clockwise

.

4. Slowly open the filling source valve and make sure 

    there are 

no leakage

. Fill the Poseidon EBS to 

200 bar/ 2900 psi

.

   

 Maximum filling pressure is 232 bar/ 3364 psi.

1. 

Close

 the cylinder valve. 

Press

 the 

purge-button

 on the 2nd stage to ensure  

    that the breathing apparatus  is 

depressurized

 before the filling process begins.

WARNING: 

 
Before you start filling the bottle, make sure you are well familiarized 
with these instructions. 

Maximum pressure of 232 bar/ 3364 psi. 

Failure to follow these instructions may lead to injury or death.

G 5/8”

5. When the Poseidon EBS if filled, 

close

 the valve on the filling source.

Purge button

Содержание EBS MkII

Страница 1: ...Poseidon EBS MkII Sea Air EBS MkII User Manual VERSION 1 3 S A R S A R...

Страница 2: ...passengers in making an emergency egress from a submerged aircraft Due to its limited air volume it is not intended egressing from depths greater than 10 meters Poseidon article number 0140 010 Manuf...

Страница 3: ...ew Cylinder valve 1st stage regulator Cylinder 0 29 liter bottle Pressure gauge Mouthpiece 2nd stage regulator Nose Clip Low Pressure Hose Serial number and date Cylinder valve in position OPEN Turnin...

Страница 4: ...he 1st stage on the 0 29 liter bottle tight and firmly rec 60 Nm WARNING Before assembly make sure all components are intact and without any visible damage Do not use if there is any sign of damage to...

Страница 5: ...he filling hose is firmly attached to the filling adapter slowly open the valve on the 1st stage by turning the valve handle counter clockwise 4 Slowly open the filling source valve and make sure ther...

Страница 6: ...the 7 16 HP port of the 1st stage and make sure it s firmly attached Before mounting the blanking plug inspect the o ring to make sure it s without any flaws make sure the o ring is lubricated and tha...

Страница 7: ...of damage to the equipment Repair of any component should only be performed by a service techni cian that is authorized to service repair the equipment Do not try to repair any component without prop...

Страница 8: ...safety valve 225 bar Cylinder Black 0 29 Liter UNF 5 8 18 200 bar 2900 psi Pressure gauge Low Pressure Hose 24 Mouthpiece Desinfection Guardian Superior 100 ml Nose clip Filling adapter Poseidon EBS...

Отзывы: