Poseidon EBS MkII / Sea Air EBS MkII Manual
Page 4
S.A.R
S.A.R
Filling instructions
If the pressure is
200 bar or more
- go to position
11
on page
6
.
Recomended filling pressure is
200 bar/ 2900 psi
.
Maximum
filling pressure is
232 bar/ 3364 psi.
Use Poseidon filling adapter art no 0800-015.
2.
Remove the blanking plug
from the 1st stage.
Inspect the O-ring and attach the filling adapter to the 7/16” HP port where the
blanking plug was mounted. Make sure the filling adapter is
firmly attached
.
Attach the filling hose to the G5/8” thread on the filling adapter.
3.
When the filling hose is
firmly attached
to the filling adapter, slowly
open
the
valve on the 1st stage by turning the valve handle
counter clockwise
.
4. Slowly open the filling source valve and make sure
there are
no leakage
. Fill the Poseidon EBS to
200 bar/ 2900 psi
.
Maximum filling pressure is 232 bar/ 3364 psi.
1.
Close
the cylinder valve.
Press
the
purge-button
on the 2nd stage to ensure
that the breathing apparatus is
depressurized
before the filling process begins.
WARNING:
Before you start filling the bottle, make sure you are well familiarized
with these instructions.
Maximum pressure of 232 bar/ 3364 psi.
Failure to follow these instructions may lead to injury or death.
G 5/8”
5. When the Poseidon EBS if filled,
close
the valve on the filling source.
Purge button