background image

-93-

 

VFD 

Customer display LCD type (16 x 2) or VFD type (20 x 2) / pole type customer display 

CF CARD 

CF card reader 

Power Supply 

INPUT: 100-240V~,50/60Hz 1.5A            OUTPUT: DC 24V 2.5A 

Qualification 

CE, FCC, KCC 

OS Support 

Windows CE 6.0 on SSD, Windows XP/XPE, POS Ready(WEPOS) on HDD, Linux 

Dimension 

325(mm) x 393(mm) x 176(mm) 

Содержание miniQ

Страница 1: ......

Страница 2: ...Replacement 82 2 3 Product Outline 13 3 11 Set Supervisor Password 67 Motherboard Replacement 84 2 4 Installation of Optional Devices 17 3 12 Set User Password 69 Memory Replacement 86 CDP Installati...

Страница 3: ...new or refurbished replacement parts free of charge with one way shipping costs borne by the seller The customer shall however be responsible for the return delivery costs The 2nd year also includes...

Страница 4: ...static appliances Doing so may cause inferior reliability and shorted product life 4 Keep product away from highly static areas This may lead to inferior performance and reduced life cycle 5 Do not i...

Страница 5: ...d by these qualifications safety regulations However the product can affect and be affected by other high frequencies generated around it As such POSBANK does not consider liability for any system err...

Страница 6: ...tly taking particular care when dealing with the LCD display screen Product limitations 1 The use of this product for anything other than POS tasks is strictly prohibited The product is not supported...

Страница 7: ...one to shocks or vibration 7 Install product away from sewing machines welding equipment electric stoves audio equipment and other high frequency generating equipment 8 Installation and use in close p...

Страница 8: ...firm its contents 2 The POS terminal main unit power cable user manual roll paper and driver CD are included in the package If any items are missing or damaged please contact your dealer for assistanc...

Страница 9: ...9 Package Contents miniO main unit User manual Power cable Driver CD Roll paper...

Страница 10: ...10 Optional Customer Display CDP Normal CDP Pole type CDP...

Страница 11: ...11 Optional PLU Keyboard PLU Keyboard 55Key Image of Main Unit with PLU Keyboard...

Страница 12: ...12 Optional Mini Keyboard Mini Keyboard Image of Main Unit with Mini Keyboard...

Страница 13: ...creen to prevent possible operating difficulties 2 Attach all optional parts before setting up the main POS unit 2 3 Product Outline Each part of product may differ depending on the specific POS model...

Страница 14: ...14 Side View 2 Printer Printer OPEN button Printer FEED switch CF card socket LCD Touch panel display Smart Card Reader SCR Magnetic Stripe Reader MSR Printer RESET switch Printer ON Error LED...

Страница 15: ...15 Top View Customer display optional Power HDD LAN LED Power switch I Button Keyboard LOCK switch RESET switch USB port...

Страница 16: ...16 Power I O Ports Description Description 1 USB port 5 Power connector 2 Ethernet port LAN 6 Fiscal PC switch 3 Cash box port 7 Modem port 4 COM1 COM2 port...

Страница 17: ...e when opening main unit or installing optional devices 1 Insert driver in the grooves marked and detach cover from main unit 2 Connect to the main unit using the CDP cable and install After successfu...

Страница 18: ...g main unit or installing optional devices 1 Insert driver in the grooves marked and detach cover from main unit 2 Connect to the main unit using the CDP cable and install After successful installatio...

Страница 19: ...tion 1 Put driver in the grooves marked and detach dummy cover from main unit 2 Connect cable to interface connector 3 Insert keyboard into main unit from above After successful installation of O S an...

Страница 20: ...0 Some USB devices optional devices are only functional with specific driver software installed If multiple USB devices are used together this may result in abnormal functionality Using a USB hub with...

Страница 21: ...21 Connection via Ethernet Port LAN The Ethernet port located at the rear I O supports 10 100 1000Mbps using an RJ45 connector cable When connected properly the LAN LED light will be switched on...

Страница 22: ...at the rear I O and supports 24V Solenoid type The cash drawer port is connected to the internal printer on the mother board The POS will not operate properly if no printer is attached to the POS The...

Страница 23: ...23 Power Cable Connection Insert power cable into power connector socket INPUT 100 240V 50 60Hz 1 5A OUTPUT DC 24V 2 5A...

Страница 24: ...witching On POS Ensure that all additional POS accessories and peripherals are switched on before switching on the POS 1 Press Power button on the POS unit POWER LED will light up 2 Confirm that Windo...

Страница 25: ...Off Computer Shut Down Please make sure that you have closed all applications before terminating Windows Alternatively you may shut down Windows by simply pressing the Power switch on the Main Unit Y...

Страница 26: ...ter FEED Button Press the FEED button once to discharge extra paper Holding down the FEED button will discharge paper continuously until the button is released again PRINTER ON ERROR LED Displays Prin...

Страница 27: ...ile holding down the FEED button turn on the power to begin the self test 4 Self test 2 When miniO is powered On While holding down the printer RESET button press the FEED button Next release the prin...

Страница 28: ...Switch Settings 1 Detach integrated printer from main unit 2 Check DIP SW on underside of printer Warning Ensure power is OFF when changing the dip switch settings Tip Change density setting to Normal...

Страница 29: ...FF OFF 9600 BPS OFF ON OFF 19200 BPS ON ON OFF 38400 BPS OFF OFF ON 57600 BPS ON OFF ON 115200 BPS OFF ON ON 2 RS232 C Handshaking SW1 4 DTR DSR DTR DSR OFF XON XOFF ON 3 Auto cutter SW2 7 Enable Enab...

Страница 30: ...30 No Function Setting Default 5 Print density SW1 7 SW1 8 Low Low power OFF OFF Normal ON OFF Slightly OFF ON Dark ON ON 6 Auto cutter function SW2 8 Partial cut Partial cut OFF Full cut ON...

Страница 31: ...F OFF OFF 9 CP 852 Latin II OFF OFF OFF ON OFF OFF 10 CP 858 Euro ON OFF OFF ON OFF OFF 11 Thai 42 Thailand characters OFF ON OFF ON OFF OFF 12 Thai 11 ON ON OFF ON OFF OFF 13 Thai 14 Thailand charact...

Страница 32: ...Hebrew ON ON OFF ON ON OFF 29 CP 1256 Arabic OFF OFF ON ON ON OFF 30 CP 1257 Baltic ON OFF ON ON ON OFF 31 CP 1258 Vietnamese OFF ON ON ON ON OFF 32 CP 950 Traditional Chinese Big5 OFF OFF ON ON ON ON...

Страница 33: ...gram so that the computer can recognize these changes and record them in the CMOS RAM of the firmware hub The firmware hub on the motherboard stores the Setup utility When you start up the computer th...

Страница 34: ...Return to the main menu from a sub menu or prompts you to quit the setup program Move to the item in the left or right hand Move to previous or next item Enter Brings up a selection menu for the highl...

Страница 35: ...enu appears Use the legend keys to enter values and move from field to field within a sub menu as you would within a menu Use the Esc key to return to the main menu Take some time to familiarize yours...

Страница 36: ...appears The BIOS menu screen displays the items that allow you to make changes to the system configuration To access the menu items press the up down right left arrow key on the keyboard until the de...

Страница 37: ...37 3 3 Standard CMOS Features The Standard CMOS Features screen gives you an overview of the basic system...

Страница 38: ...m start up faster Manual User can manually input the correct settings Access Mode The options are CHS LBA Large Auto Capacity Capacity of currently installed hard disk Cylinder Number of cylinders Hea...

Страница 39: ...errors according to the system functions specified in each option Configuration options All Errors No Errors All But Keyboard Memory This category displays base memory extended memory and total memory...

Страница 40: ...e Initial Setup Screen menu It allows the user to configure the RX945G according to their particular requirements Below are some major items that are provided in the Advanced BIOS Features screen A qu...

Страница 41: ...41 Hard Disk Boot Priority Set hard disk boot device priority...

Страница 42: ...ausing a warning message to appear when anything attempts to access the boot sector or hard disk partition table Disable No warning message will appear when anything attempts to access the boot sector...

Страница 43: ...st Second Third Boot Device The BIOS tries to load the OS from the devices in the sequence set here The options are Item Description LS120 LS120 Device HDD Hard Disk Device CDROM CDROM Device ZIP100 Z...

Страница 44: ...the keyboard controller controls GateA20 Fast Lets chipset control GateA20 Default Security Option This category determines whether a password is required when the system boots up or only when enteri...

Страница 45: ...gn and build Intel architecture systems with two or more processors MPS 1 1 was the original specification MPS version 1 4 adds extended configuration tables for improved support of multiple PCI bus c...

Страница 46: ...46 3 5 Advanced Chipset Features...

Страница 47: ...arge Controls the idle clocks after issuing a precharge command to the DDRSDRAM Precharge Delay tRAS This setting determines the timing delay for DRAM precharge System Memory Frequency Allows user to...

Страница 48: ...y is shared with the system memory DVMT Mode Use this field to select the type of memory to allocate as video memory Configuration options Fixed DVMT and BOTH DVMT FIXED Memory Size Specify the size o...

Страница 49: ...49 3 6 Integrated Peripherals Use this menu to specify settings for integrated peripherals...

Страница 50: ...50 OnChip IDE Device...

Страница 51: ...for each of the four IDE devices that the onboard IDE interface supports Modes 0 through 4 provide successively increased performance In Auto mode the system automatically determines the best mode for...

Страница 52: ...52 Onboard Device Azalia Audio Select Select Disabled if you do not want to use Azalia audio Configuration options Auto Disabled...

Страница 53: ...53 SuperIO Device Onboard Serial Port 1 2 The configuration options are 3F8 IRQ4 2F8 IRQ3 3E8 IRQ4 2E8 IRQ3 and Disabled for the on board serial connector...

Страница 54: ...On Former Sts Onboard Lan1 2 Boot ROM Configuration options Enable Disable Watch Dog Timer Select This option allows you to configure the watch dog timer Configuration options Disabled 10 20 30 40 Se...

Страница 55: ...USB 1 0 Controller If your system has a USB controller installed on the system board select Enabled to make it usable Even if equipped in case you wish to add a higher performance controller this feat...

Страница 56: ...he USB 2 0 controller USB Keyboard Function Select Enabled if your system contains a USB controller and you wish to use a USB keyboard USB Mouse Function Select Enabled if your system contains a USB c...

Страница 57: ...57 3 7 Power Management Setup The power management setup controls the single board computer s green features for power saving...

Страница 58: ...ription Min Power Saving Minimum power management HDD Power Down 15 Min Max Power Saving Maximum power management HDD Power Down 1 Min User Defined Allows you to set each parameter individually When n...

Страница 59: ...1 min and 1 hr with the exception of HDD Power Down which ranges from 1 min to 15 min and disable HDD Power Down Select 1 15 min to enable HDD Power Down mode between 1 to 15 min Select Disabled to di...

Страница 60: ...al Ring Indicator RI line The choices are Disabled Enabled USB KB Wake up From S3 When Enabled enter any key to wake up the system from S3 state The choices are Disabled Enabled Resume by Alarm When E...

Страница 61: ...61 3 8 PnP PCI Configuration...

Страница 62: ...g Resources Controlled By Selecting Manual requires you to choose resources from the sub menu Auto ESCD automatically configures all of the boot and Plug and Play devices Windows 95 or above PCI VGA P...

Страница 63: ...63 3 9 PC Health Status Shutdown Temperature Defines the core system temperature at which the system will automatically shutdown to prevent damage by overheating...

Страница 64: ...ature Current CPU1 Temperature Displays the current CPU temperature CPU Fan Speed Displays the current CPU fan speed System Fan Speed Displays the current system fan speed Vcore Displays the current V...

Страница 65: ...65 Smart Fan Function Performance Mode Fan is activated at 40 Optimal Mode Fan is activated at 50 Silent Mode Fan is activated at 60...

Страница 66: ...10 Load Optimized Defaults Use this menu to load the BIOS default values for minimal stable system operation Press Y to load the BIOS default values for the most stable optimal performance system oper...

Страница 67: ...67 3 11 Set Supervisor Password Allows you to set a password for entering altering setup menu options...

Страница 68: ...ll be asked for the password to be stored in the CMOS Next the following message will appear Please Confirm Your Password Type the password once more and press Enter After pressing Enter the ROM passw...

Страница 69: ...69 3 12 Set User Password Allows you to set a password for entering altering setup menu options...

Страница 70: ...be asked for the password to be stored in the CMOS Next the following message will appear Please Confirm Your Password Type the password once more and press Enter After pressing Enter the ROM password...

Страница 71: ...ll changed entries to the CMOS memory of the chipset Press Y to save values or N to not save at this time Every time the system is switched on the processor will check and compare these values to what...

Страница 72: ...option when exiting allows you exit the setup program without recording any new values or changing old ones to the CMOS To discard all changes and exit the setup press Y otherwise press N to go back w...

Страница 73: ...nection Check LED Window LAN on off Reinstall LAN card Connect LAN to motherboard after removing mother board and I O LAN cable Replace motherboard 4 2 MSR Issues Symptom Corrective Procedure MSR does...

Страница 74: ...ce motherboard 4 4 LCD Issues Symptom Corrective Procedure LCD backlight doesn t work Check LCD cable connection Check inverter cable connection Replace inverter cable Replace LCD panel 4 5 Touch scre...

Страница 75: ...Re booting during system operating Check serial peripheral devices connection status Check USB peripheral devices connection status Check device manager Replace power supply unit and or motherboard 4...

Страница 76: ...76 Chapter 5 Motherboard 5 1 Motherboard Layout...

Страница 77: ...77...

Страница 78: ...he RTC RAM 1 Turn OFF the computer and unplug the power cord 2 Remove the onboard battery 3 Move the jumper cap from pins 1 2 default to pins 2 3 Keep the cap on pins 2 3 for 5 10 seconds then move th...

Страница 79: ...79 5 3 Serial Port Power Jumper Settings 12V RI 5V COM1 Port COM2 Port COM3 Port COM4 Port COM6 Port COM5 Port...

Страница 80: ...SEL6 to pins 1 3 and pin 2 4 to select normal RS 232 Set COMP6SEL6 to pins 3 5 and 4 6 to select TTL level for COMHD6 NORMAL RS 232 TTL LEVEL 5 4 STACON1 This jumper allows you to use SATA DOM on SATA...

Страница 81: ...outlet 2 Disconnect all cables from the POS main unit before attempting reparation 3 Keep all components in the static proof packaging provided until ready for installation 4 If the device still is n...

Страница 82: ...82 HDD Replacement 1 Remove the 4 screws from the underside of main unit as shown above 2 Remove cover from unit 3 Remove screw from metal frame attached to HDD...

Страница 83: ...83 4 Disconnect cable connected to HDD 5 Replace with new HDD and reassemble unit using the reverse procedure of steps 1 4 as shown previously...

Страница 84: ...84 Motherboard Replacement 1 Remove screw from the underside of main unit as shown above 2 Detach bottom cover using hooks on both sides 3 Remove the 4 screws from the area shown above...

Страница 85: ...85 4 Disconnect cable connected to the motherboard 5 Replace with new motherboard and reassemble unit using the reverse procedure of steps 1 4 as shown previously...

Страница 86: ...AM Replacement 1 First remove motherboard as shown on P 83 2 Push fixtures on both sides outwards as shown above and remove the memory from its slot 3 Insert new memory in slot and press lightly to fi...

Страница 87: ...e of main unit as shown above 2 Detach bottom cover using hooks on both sides 3 Disconnect cable connected to SSD and remove by pushing the SSD clip 4 Replace with new SSD and reassemble unit using th...

Страница 88: ...88 MSR Replacement 1 Remove the 2 screws as shown above 2 Disconnect cable connected to MSR 3 Replace with new MSR and reassemble unit using the reverse procedure of steps 1 2 as shown previously...

Страница 89: ...cover to open cover 2 Install new roll of paper as shown above 3 Slightly draw out end of the roll and close printer cover Open button After closing the printer cover ensure to press the centre of th...

Страница 90: ...90 Printer Replacement 1 Remove the lever screw at side of main unit as shown above 2 Open printer cover and remove both screws from inside...

Страница 91: ...91 3 Pull printer upwards to unlock and detach from main unit 4 Replace with new printer and reassemble unit using the reverse procedure of steps 1 3 as shown previously...

Страница 92: ...reserved for internal printer USB 1 x touch screen 1 x keyboard 1 x MSR 1 x I Button reserved 1 x SCR RS 232 COM 4 reserved for VFD or 2nd display COM 3 reserved for 2 mini printer LVDS Main display...

Страница 93: ...20 x 2 pole type customer display CF CARD CF card reader Power Supply INPUT 100 240V 50 60Hz 1 5A OUTPUT DC 24V 2 5A Qualification CE FCC KCC OS Support Windows CE 6 0 on SSD Windows XP XPE POS Ready...

Страница 94: ...Curved Detection Head temperature By thermistor Platen position By mechanical switch Out of paper By photo interrupter Cutter home position By photo interrupter Power Supply V Operation voltage Vdd 2...

Страница 95: ...ut Leave center point Operating time sec cycle max Approx 0 5 Cutting pitch mm min 10 Cut frequency cut min max 30 Service life Pulse activation 100 million Abrasion resistance km 100 1 Life cut 700 0...