15
WIRING REQUIREMENTS – POWR-TOUCH
®
OPERATION
12.
CHECK HEIGHT ADJUSTMENT OPERATION – In order to test operation of height adjuster, use a temporary hook-up, or test
after unit has been hard-wired to the Powr-Touch
®
relay panel per the diagram below. Operate unit down to the 8'-0" goal height,
then back up to 10'-0".
NOTE – All wiring between the height adjuster and the Powr-Touch
®
relay panel is to be done by an electrical contractor per the
diagram below, to meet all local code requirements.
13.
Demonstrate the operation of the unit to the customer. Give this instruction booklet to the customer. Make the customer aware of
the Cautions, the Warnings, and the Maintenance requirements listed on Page 16 and 17.
IMPORTANT NOTE
- PERFORMANCE OF MOTOR IS BASED ON HAVING 115 VOLTS AT MOTOR TERMINALS.
VOLTAGES LESS THAN 115 VOLTS WILL AFFECT HOISTING CAPACITY AND RESULT IN DAMAGE TO MOTOR, THUS
VOIDING WARRANTY.
90' to 140' RUN
90' MAXIMUM RUN
MINIMUM WIRE SIZE
OVER 140'
CAUTION
POWR-TOUCH
£
KEYPAD MUST BE
MOUNTED ON THE
WALL IN A LOCATION
SO THAT THE
EQUIPMENT IT IS
CONTROLLING IS IN
FULL VIEW OF THE
OPERATOR.
BLACK (UP)
RED (DOWN)
WHITE
GREEN\GROUND
- 10 GA.
- 12 GA.
- 8 GA.
GREEN/GROUND
TO RELAY SET IN RELAY PANEL OF POWR-TOUCH
£
CONTROL SYSTEM. REFER TO POWR-TOUCH
£
INSTALLATION MANUAL FOR COMPLETE WIRING DIAGRAM.
TO JUNCTION BOX ON
HEIGHT ADJUSTER FRAME
UP
DOWN
NEUTRAL
ELECTRICIAN NOTE - IF HEIGHT
ADJUSTER OPERATION DOES
NOT CORRESPOND TO UP AND
DOWN BUTTONS ON KEYPAD,
REVERSE BLACK AND RED
WIRES.
ELECTRICAL CONTRACTOR TO PROVIDE
FIELD WIRING AS REQUIRED TO MEET ALL
LOCAL ELECTRICAL CODES.
NOTE