WARNING

READ ALL INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING TO INSTALL THIS EQUIPMENT. 

 

INSTALLATION / ASSEMBLY OF THIS EQUIPMENT MUST BE DONE 

ONLY BY TRAINED INDIVIDUALS,

 WHO ARE 

PHYSICALLY CAPABLE.  DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY INCREASE RISK OF 
INJURY BY ATHLETES. 

WARNING

BASEBALL GAME PLAY IS AN INHERENTLY DANGEROUS SPORT.  ACTIVITIES SUCH AS SLIDING INTO BASES 
OR HOME PLATE INCREASE THE PROBABILITY OF INJURY.  PORTER ATHLETIC, INC. EXPLICITLY DISCLAIMS 
LIABILITY OF ANY INJURY RESULTING IN USE OF THIS EQUIPMENT, AND IT IS THE END USER’S 
RESPONSIBILITY TO ADVISE ATHLETES, OR PARTICIPANTS OF RISKS ASSOCIATED IN BASEBALL GAME PLAY.   

WARNING

PORTER ATHLETIC, INC. BASEBALL BASES, HOME PLATES AND PITCHER PLATES ARE DESIGNED AS A 
REFERENCE POINT ONLY ON A BASEBALL FIELD.  

I

NVENTORY AND 

I

NSPECTION

Inventory parts listed with the list below to ensure parts required are accounted for.  Inspect all 
components for possible damage.  Report any shortages to Porter's Customer Service Department 
immediately.  Failure to report shortages or damage directly to Porter's Customer Service Department 
within three working days will place the financial burden for the missing or replacement parts with the 
installer or general contractor. 

NOTE

ALL PRODUCTS SHOULD BE INSPECTED SEMI-ANNUALLY AND BE REPAIRED OR REPLACED AS NEEDED.  
THEY ARE NOT INTENDED TO BE USED IN CONJUNCTION WITH SLIDING

P

ARTS

L

IST

Porter No. 33200 

– set of one (1) Home Plate, Anchor Stake and Stake Plug. 

Porter No. 33201 

– set of one (1) Home Plate with five (5) 4" long spikes. 

Porter No. 33210 

– set of three (3) Base, Anchor Stake, & Stake Plug. 

Porter No. 33211 

– set of three (3) Base, Anchor Stake, & Stake Plug 

Porter No. 33220 

– set of one (1) Pitchers' Plate 

Porter No. 33221

 – set of one (1) Pitchers' Plate with three (3) 4" long spikes. 

NOTE

For ordering of replacement parts (anchor stakes and stake plugs) reference part numbers below.

Stake 

Plug 

    Anchor 

Stake 

Female 

   Anchor 

Stake 

Male 

Porter 

No. 

33232 

   Porter 

No. 

33230 

   Porter 

No. 

33231 

Содержание 33200

Страница 1: ...EBALL BASE w ANCHOR PLUG SET OF 3 No 33210 BASEBALL BASE w ANCHOR PLUG SET OF 3 No 33211 PITCHERS PLATE No 33220 PITCHERS PLATE w SPIKES No 33221 INST 00447 058 2008 PORTER ATHLETIC INC ALL RIGHTS RESERVED 5 1 2008 Porter No 33200 Porter No 33211 Porter No 33201 Porter No 33220 Porter No 33221 Porter No 33210 ...

Страница 2: ...accounted for Inspect all components for possible damage Report any shortages to Porter s Customer Service Department immediately Failure to report shortages or damage directly to Porter s Customer Service Department within three working days will place the financial burden for the missing or replacement parts with the installer or general contractor NOTE ALL PRODUCTS SHOULD BE INSPECTED SEMI ANNU...

Страница 3: ...box until flush with the top edge The anchor stake should be approximately 3 above the top edge of the box Allow a minimum of 24 hours for the concrete to fully cure before removing the form box and installing into footing location 3 Make sure the baseball diamond is level before excavating footing location 4 Excavate footing location minimum 9 deep from ground level Top edge of the anchor stake s...

Страница 4: ...uld be approximately 3 3 4 above the top edge of the box Allow a minimum of 24 hours for the concrete to fully cure before removing the form box and installing into footing location 3 Make sure the baseball diamond is level before excavating footing location 4 Excavate footing location minimum 9 3 4 deep from ground level Top edge of the anchor stake shall be a minimum of 1 below level grade Ancho...

Страница 5: ... should be approximately 3 above the top edge of the box Allow a minimum of 24 hours for the concrete to fully cure before removing the form box and installing into footing location 3 Make sure the baseball diamond is level before excavating footing location 4 Excavate footing location minimum 9 deep from ground level Top edge of the anchor stake shall be a minimum of 1 below level grade Anchor st...

Страница 6: ...neral contractor 2 Install the five 5 4 long metal spikes supplied with home plate to the bottom side of plate 3 With home plate s position determined excavate location 1 below level ground and approximately 1 larger than the dimensions of home plate 4 With the five 5 spikes pointing toward the ground and the home plate oriented correctly push the home plate into the ground Note the topside of the...

Страница 7: ...2 Install the three 3 4 long metal spikes supplied with pitchers plate to the bottom side of plate 3 With the pitchers plate s position determined excavate location 1 below ground and approximately 1 larger than the dimensions of pitchers plate 4 With the three 3 spikes pointing toward the ground and the pitcher plate oriented correctly push the pitchers plate into the ground Note the topside of t...

Страница 8: ...ion 6 below ground and approximately 1 larger than the dimensions of pitchers plate 3 With the pitchers plate oriented correctly within the excavated footing the topside of the pitchers plate shall be no higher or lower than the grade of the pitchers mound See Detail F 4 Backfill excess excavation as required www porterathletic com 888 277 7778 SAVE THESE INSTRUCTIONS FOR FUTURE USE DETAIL F WARNI...

Отзывы: