TROUBLESHOOTING
WARNING:
Disconnect tool from air supply before performing any
Service Procedure.
SYMPTOM PROBLEMS
SOLUTIONS
1. Air leak near rear of
Loose screws.
Tighten screws.
tool or in trigger area.
Worn or damaged
Install Overhaul Kit.
o-rings or seals.
2. Tool does nothing or
Inadequate air supply.
Verify adequate air supply.
operates sluggishly.
Inadequate lubrication.
Put 2 or 3 drops of oil into air inlet.
Worn or damaged
Install Overhaul Kit.
o-rings or seals.
Pin jammed in nose.
Remove front plate and clear.
3. Air leak near bottom
Loose screws.
Tighten screws.
of tool.
Worn or damaged
Install Overhaul Kit.
o-rings or bumper.
4. Tool jams frequently.
Incorrect fasteners.
Verify approved fasteners of
correct size.
Pin fragment jammed in nose. Remove front plate and clear.
Fasteners loaded
Verify arrow printed on fastener strip
incorrectly.
points toward workpiece.
Damaged fasteners.
Replace w/undamaged fasteners.
Magazine or nose
Tighten screws.
screws loose.
Magazine is dirty.
Clean magazine.
Driver is worn or damaged.
Install Driver Maintenance Kit.
5. Other.
Contact a Porter-Cable
Service Facility.