EMPLOYER’S RESPONSIBILITIES

DANGER:

Employer must enforce compliance with the safety warnings

and all other instructions contained in this manual.

Keep this manual available for use by all people assigned to use this tool.
For personal safety and proper operation of this tool, read and understand
tool labels and manual. Failure to follow warnings could result in DEATH or
SERIOUS INJURY. Read and follow all of these instructions carefully.

FUNCTIONAL DESCRIPTION

FOREWORD

Porter-Cable Model PIN100 is a pneumatic pin nailer. It is designed to install
23 gauge wire pins of various lengths from 

1

/

4

" to 1" long.

WARNING: 

Use approved Porter-Cable fasteners only.

POWER SOURCE

This tool is designed to operate on clean, dry, compressed air at regulated
pressures between 60 and 100 PSI (Pounds per Square Inch)(4.1 to 6.9 BAR).
The preferred system would include a filter, a pressure regulator, and an
automatic oiler located as close to the tool as possible (within 15 ft/4.6 m is
ideal).

All compressed air contains moisture and other contaminates that are
detrimental to internal components of the tool. An air line filter will remove
most of these contaminates and significantly prolong the life of the tool. If an
in-line oiler is not available: place 2 or 3 drops of Porter-Cable Air Tool Oil
into the tool’s air inlet at the beginning of each workday.

The tool is equipped with a 

1

/

4

" male “quick connector”. A 

3

/

8

" male “quick

connector” is available from Porter-Cable and may be used in situations where

1

/

4

" supply line is not available. The tool must always be connected to the air

supply with a coupling such that all pressure is removed from the tool when the
coupling is disconnected.

DANGER: 

All air line components (hoses, connectors, filters, regulators,

etc.) must have a minimum working pressure rating of at least 150 PSI
(10.3 BAR) or 150% of maximum system potential, whichever is greater.

Do not connect tool to pressure which potentially exceeds 200 PSI
(13.7 BAR).

Only connect tool to air supply hose with a coupling that
automatically removes all pressure from the tool when the coupling
is disconnected.

Disconnect tool from air supply before performing maintenance,
clearing a jammed fastener, leaving work area, moving tool to
another location, or handing the tool to another person.

TECHNICAL SPECIFICATIONS

Noise level

 . . . . . . . . . . . . . . . . . .

Typical Mean 

A - Weighted sound impulse

 . . .

effective Acceleration  . . . . 1.2 m/s

2

power level  . . . . . . . 91 dBA

P - Emission sound pressure

pressure level . . . . . . 84 dBA

903607- 01-23-02.qxd  1/29/02  12:51 PM  Page 6

Содержание PIN100

Страница 1: ...PIN NAILER Instruction manual MODEL PIN100...

Страница 2: ...manual Failure to follow warnings could result in DEATH or SERIOUS INJURY Fig 1 2 Operator and others in work area MUST wear safety glasses with side shields These safety glasses must conform to ANSI...

Страница 3: ...Make sure all screws and caps are securely tightened Fig 8 14 Never use tool if trigger or springs are inoperable missing or damaged Do not alter or remove trigger or springs Make daily inspections fo...

Страница 4: ...other fasteners or with the tool at too steep an angle the fasteners can ricochet causing personal injury Fig 15 26 Do not drive fasteners close to the edge of the workpiece The workpiece is likely t...

Страница 5: ...ost of these contaminates and significantly prolong the life of the tool If an in line oiler is not available place 2 or 3 drops of Porter Cable Air Tool Oil into the tool s air inlet at the beginning...

Страница 6: ...ts or requires repair 2 Turn tool upside down depress latch 1 Fig 19 and slide magazine cover 2 Fig 19 open Make certain the secondary trigger B Fig 19 has locked out the primary trigger A Fig 19 to p...

Страница 7: ...g work area moving tool to another location or handing the tool to another person WARNING Clean and inspect tool daily Carefully check for proper operation of trigger and safety mechanism Do Not use t...

Страница 8: ...line oiler place 2 or 3 drops of Porter Cable Air Tool Oil into the air inlet of the tool at the beginning of each workday SERVICE AND REPAIRS All quality tools will eventually require servicing or re...

Страница 9: ...o rings or seals Pin jammed in nose Remove front plate and clear 3 Air leak near bottom Loose screws Tighten screws of tool Worn or damaged Install Overhaul Kit o rings or bumper 4 Tool jams frequentl...