background image

24- ENG

A02258

LIMITED WARRANTY

PORTER-CABLE CORPORATION

warrants to the original purchaser that each new air

compressor and service part is free from defects in material and workmanship and
agrees to repair or replace under this warranty any defective product or part as follows
from the original date of purchase.

5 YEARS

– Limited warranty on 2-stage oil-free air compressor

pumps

that operate

at 1725 RPM and 1 year limited warranty on all other parts.

3 YEARS

– Limited warranty on oil-lubricated air compressor 

pumps

and 1 year

limited warranty on all other parts.

1 YEAR 

– Limited warranty on all other air compressor products.

90 Day 

– Service parts

Engine warranties are the responsibility of the engine manufacturer. Warranties of
merchandise sold by Porter-Cable which has been manufactured by and identified as the
product of another company are the responsibility of the manufacturer of that product.

THIS WARRANTY IS NOT TRANSFERABLE AND DOES NOT COVER

Products sold damaged or incomplete, sold “as is”, sold reconditioned or used as
rental equipment.

Delivery, installation or normal adjustments explained in the owner’s manual.

Damage or liability caused by shipping, improper handling, improper installation,
incorrect voltage or improper wiring, improper maintenance, improper modification,
or the use of accessories and/or attachments not specifically recommended by
PORTER-CABLE for the tool.

Repairs necessary because of operator abuse or negligence, or the failure to install,
operate, maintain and store the product according to the instructions in the owner’s
manual.

Damage caused by cold, heat, rain, excessive humidity, corrosive environments and
materials, or other contaminants.

Expendable items that become worn during normal use such as drain valves, fuses,
filters, belts, air cleaners, spark plugs, engine oil and pump oil.

Cosmetic defects that do not interfere with tool functionality.

Freight costs from customer to Porter-Cable.

Repair and transportation costs of products or parts determined not to be defective.

ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE,  OR
EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE OR
MALFUNCTION OF THE PRODUCT. 

Some states  do not allow the exclusion or

limitation of incidental or consequential damages, so the above limitation or
exclusion may not  apply to you.

IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM
THE DATE OF ORIGINAL PURCHASE.

Some states do not allow  limitations on

how long an implied warranty lasts, so the above limitations may not apply to you.

WARRANTY SERVICE

is available by delivering or shipping the defective product or

part to any Porter-Cable authorized warranty service location. To determine the nearest
authorized warranty service location, call the toll free number, 1-888-559-8550, 24 hours
a day, 7 days a week. Specific instructions regarding servicing arrangements and
scheduling may vary depending on the type and size of the product and the availability of
repair parts.

DO NOT return the defective product to the retailer.

Retain the original cash register sales receipt as proof of purchase for warranty
work.

Only Air compressors with 60 and 80 gallon tanks will be inspected at the site of
installation. 

The customer should contact Porter-Cable directly if the purchaser does not receive
satisfactory results from the authorized warranty service center.

Porter-Cable Corporation

4825 Highway 45 North

P.O. Box 2468

Jackson, TN 38302-2468

1-888-559-8550

Содержание CPLDC2541S

Страница 1: ...instructions before starting operations Part No A02258 041 0 ESPA OL P GINA 25 FRAN AIS PAGE 49 To learn more about Porter Cable visit our website at http www porter cable com CPLDC2541S Copyright 200...

Страница 2: ...State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are G lead from lead based paints G crystalline silica from bricks and cement and other ma...

Страница 3: ...M ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS OPERATE COMPRESSOR IN A CLEAN DRY WELL VENTILATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AR...

Страница 4: ...BALLS BASKETBALLS ETC 1 FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATION...

Страница 5: ...TICLES FROM THE TANK BREATHING THESE CONTAMINANTS CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOLVENTS PAINT REMOVER INSECTICIDES WEED KILLERS MAY CONTAIN HARMFUL VAPORS AN...

Страница 6: ...TEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN HAZARD HOW TO PREVENT IT WHAT CAN...

Страница 7: ...PERSONS PETS AND OBSTACLES KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL TIMES DO NOT OPERATE THE PRODUCT WHEN FATIGUED OR UNDER THE INFLUENCE OF ALCOHOL OR DRUGS STAY ALERT AT ALL TIMES NEVER DEF...

Страница 8: ...ir compressors should be operated on not more than a 50 duty cycle This means an air compressor that pumps air more than 50 of one hour is considered misuse because the air compressor is undersized fo...

Страница 9: ...in an air compressor They leave carbon deposits on critical components thus reducing performance and compressor life Use air compressor oil only NOTE Use an air compressor oil such as SAE 30 API CG CD...

Страница 10: ...are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qualified elect...

Страница 11: ...and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is...

Страница 12: ...ys less than or equal to the tank pressure Tank Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure g...

Страница 13: ...sure release valve located on the side of the pressure switch is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches cut out p...

Страница 14: ...k connect plug if the air outlet is equipped with a quick connect socket Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and ac...

Страница 15: ...ty and or hostile environment will require a greater frequency of all maintenance checks Unit cycles automatically when power is on When performing maintenance you may be exposed to voltage sources co...

Страница 16: ...to OFF 2 Remove dipstick A and check oil on dipstick for visual signs of contaminants water dirt etc Make sure air vent C in dipstick is free from debris If air vent is blocked pressure can build in...

Страница 17: ...e motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor will automatically restart after the motor cools...

Страница 18: ...needs to be cleaned or replaced 8 Clean or replace the check valve A solvent such as paint or varnish remover can be used to clean the check valve 9 Apply sealant to the check valve threads Reinstall...

Страница 19: ...ain valve NOTE If drain valve is plugged release all air pressure The valve can then be removed cleaned then reinstalled 8 Protect the electrical cord and air hose from damage such as being stepped on...

Страница 20: ...gs where air can be heard escaping Check fittings with soapy water solution DO NOT OVERTIGHTEN Air leaks at fittings Air leaks at pressure switch release valve if equipped Defective pressure switch re...

Страница 21: ...the Air Filter paragraph in the Maintenance section Pressure reading on the regulated pressure gauge if equipped drops when an accessory is used It is normal for some pressure drop to occur If there...

Страница 22: ...load switch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Loose electr...

Страница 23: ...ll leaks it should be replaced Compressor mounting screws loose Tighten mounting screws see Parts manual for torque specifications Carbon build up in pump Have checked by a Trained Service Technician...

Страница 24: ...materials or other contaminants Expendable items that become worn during normal use such as drain valves fuses filters belts air cleaners spark plugs engine oil and pump oil Cosmetic defects that do n...

Отзывы: