background image

5- ENG

A02258

HAZARD

HOW TO PREVENT IT

WHAT CAN HAPPEN

HAZARD

HOW TO PREVENT IT

WHAT CAN HAPPEN

RISK TO BREATHING

AIR

OBTAINED DIRECTLY FROM THE

COMPRESSOR 

SHOULD NEVER BE USED TO

SUPPLY AIR FOR HUMAN CONSUMPTION.

IN

ORDER TO USE AIR PRODUCED BY THIS
COMPRESSOR FOR BREATHING, SUITABLE

FILTERS AND

IN-LINE 

SAFETY EQUIPMENT

MUST BE PROPERLY INSTALLED

. IN-LINE

FILTERS AND SAFETY EQUIPMENT

USED IN

CONJUNCTION WITH THE COMPRESSOR

MUST BE CAPABLE OF TREATING AIR TO ALL
APPLICABLE LOCAL AND FEDERAL CODES
PRIOR TO HUMAN CONSUMPTION.

WORK IN AN AREA WITH GOOD CROSS-
VENTILATION.  

READ AND 

FOLLOW THE

SAFETY INSTRUCTIONS

PROVIDED ON THE

LABEL OR SAFETY DATA SHEETS 

FOR THE

MATERIAL YOU ARE SPRAYING. USE A
NIOSH/MSHA APPROVED RESPIRATOR

DESIGNED FOR USE WITH YOUR SPECIFIC
APPLICATION.

THE 

COMPRESSED AIR

DIRECTLY FROM

YOUR COMPRESSOR 

IS NOT SAFE FOR

BREATHING

. THE 

AIR STREAM MAY

CONTAIN CARBON MONOXIDE, TOXIC
VAPORS, OR SOLID PARTICLES

FROM THE

TANK. 

BREATHING

THESE

CONTAMINANTS

CAN CAUSE SERIOUS INJURY OR DEATH.

SPRAYED MATERIALS

SUCH AS PAINT, PAINT

SOLVENTS, PAINT REMOVER, INSECTICIDES,
WEED KILLERS, MAY 

CONTAIN HARMFUL

VAPORS AND POISONS.

RISK OF ELECTRICAL SHOCK

NEVER OPERATE THE COMPRESSOR
OUTDOORS WHEN IT IS RAINING OR IN WET
CONDITIONS.

NEVER OPERATE COMPRESSOR WITH
PROTECTIVE COVERS

REMOVED

OR

DAMAGED. 

ANY 

ELECTRICAL WIRING OR REPAIRS

REQUIRED ON THIS PRODUCT 

SHOULD BE

PERFORMED BY AUTHORIZED SERVICE
CENTER PERSONNEL

IN ACCORDANCE WITH

NATIONAL AND LOCAL ELECTRICAL CODES.

MAKE CERTAIN THAT THE ELECTRICAL
CIRCUIT

TO WHICH THE COMPRESSOR IS

CONNECTED 

PROVIDES PROPER

ELECTRICAL GROUNDING, CORRECT
VOLTAGE AND ADEQUATE FUSE
PROTECTION.

YOUR 

AIR COMPRESSOR IS POWERED BY

ELECTRICITY.  

LIKE ANY OTHER

ELECTRICALLY POWERED DEVICE, 

IF IT IS

NOT USED PROPERLY IT MAY CAUSE
ELECTRIC SHOCK.

REPAIRS 

ATTEMPTED

BY UNQUALIFIED

PERSONNEL CAN RESULT IN SERIOUS
INJURY OR DEATH BY ELECTROCUTION.

ELECTRICAL GROUNDING:  

FAILURE TO

PROVIDE ADEQUATE GROUNDING TO THIS
PRODUCT COULD RESULT IN SERIOUS
INJURY OR DEATH FROM ELECTROCUTION.

SEE GROUNDING INSTRUCTIONS.

Содержание CPLDC2541S

Страница 1: ...instructions before starting operations Part No A02258 041 0 ESPA OL P GINA 25 FRAN AIS PAGE 49 To learn more about Porter Cable visit our website at http www porter cable com CPLDC2541S Copyright 200...

Страница 2: ...State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are G lead from lead based paints G crystalline silica from bricks and cement and other ma...

Страница 3: ...M ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS OPERATE COMPRESSOR IN A CLEAN DRY WELL VENTILATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AR...

Страница 4: ...BALLS BASKETBALLS ETC 1 FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATION...

Страница 5: ...TICLES FROM THE TANK BREATHING THESE CONTAMINANTS CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOLVENTS PAINT REMOVER INSECTICIDES WEED KILLERS MAY CONTAIN HARMFUL VAPORS AN...

Страница 6: ...TEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN HAZARD HOW TO PREVENT IT WHAT CAN...

Страница 7: ...PERSONS PETS AND OBSTACLES KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL TIMES DO NOT OPERATE THE PRODUCT WHEN FATIGUED OR UNDER THE INFLUENCE OF ALCOHOL OR DRUGS STAY ALERT AT ALL TIMES NEVER DEF...

Страница 8: ...ir compressors should be operated on not more than a 50 duty cycle This means an air compressor that pumps air more than 50 of one hour is considered misuse because the air compressor is undersized fo...

Страница 9: ...in an air compressor They leave carbon deposits on critical components thus reducing performance and compressor life Use air compressor oil only NOTE Use an air compressor oil such as SAE 30 API CG CD...

Страница 10: ...are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qualified elect...

Страница 11: ...and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is...

Страница 12: ...ys less than or equal to the tank pressure Tank Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure g...

Страница 13: ...sure release valve located on the side of the pressure switch is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches cut out p...

Страница 14: ...k connect plug if the air outlet is equipped with a quick connect socket Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and ac...

Страница 15: ...ty and or hostile environment will require a greater frequency of all maintenance checks Unit cycles automatically when power is on When performing maintenance you may be exposed to voltage sources co...

Страница 16: ...to OFF 2 Remove dipstick A and check oil on dipstick for visual signs of contaminants water dirt etc Make sure air vent C in dipstick is free from debris If air vent is blocked pressure can build in...

Страница 17: ...e motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor will automatically restart after the motor cools...

Страница 18: ...needs to be cleaned or replaced 8 Clean or replace the check valve A solvent such as paint or varnish remover can be used to clean the check valve 9 Apply sealant to the check valve threads Reinstall...

Страница 19: ...ain valve NOTE If drain valve is plugged release all air pressure The valve can then be removed cleaned then reinstalled 8 Protect the electrical cord and air hose from damage such as being stepped on...

Страница 20: ...gs where air can be heard escaping Check fittings with soapy water solution DO NOT OVERTIGHTEN Air leaks at fittings Air leaks at pressure switch release valve if equipped Defective pressure switch re...

Страница 21: ...the Air Filter paragraph in the Maintenance section Pressure reading on the regulated pressure gauge if equipped drops when an accessory is used It is normal for some pressure drop to occur If there...

Страница 22: ...load switch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Loose electr...

Страница 23: ...ll leaks it should be replaced Compressor mounting screws loose Tighten mounting screws see Parts manual for torque specifications Carbon build up in pump Have checked by a Trained Service Technician...

Страница 24: ...materials or other contaminants Expendable items that become worn during normal use such as drain valves fuses filters belts air cleaners spark plugs engine oil and pump oil Cosmetic defects that do n...

Отзывы: