Porter-Cable CPF4515 Скачать руководство пользователя страница 9

9- ENG

A08202

ASSEMBLY

Assemble Handle

1.  To make installation easier, 

submerge handle grip into 

warm soapy water.  Remove 

handle grip from soapy water 

and slide onto handle. 

2.  Insert the handle inside the 

compressor saddle and line 

up the two bolt holes on each 

side. 

3.  Install the four screws, two on 

each side.  

4.  Tighten securely.

Assemble Wheels

It will be necessary to brace or support one side of the 
outfit when installing the wheels because the compressor 

will have a tendency to tip.

1.  Attach wheels with shoulder bolts and nuts as shown. 

NOTE: 

Place the 

bolts in the bottom hole of the wheel bracket.

2.  Tighten securely. 

NOTE

: The outfit will sit level if the wheels are properly 

installed.

The wheels and handle do not provide adequate 
clearance, stability or support for pulling the unit up and 

down stairs or steps. The unit must be lifted, or pushed up a ramp.

Assemble Rubber Feet

1.  Attach rubber feet with the screws provided as shown in previous figure. 
2.  Tighten securely.  

Rubber Feet

Screw

Nut

Wheel

Shoulder Bolt

Handle

Tools Required for Assembly

1 - 9/16" socket or open end wrench
1 - 3/8"  socket or open end wrench
1 - 1/2"  socket or open end wrench

Unpacking

1.  Remove unit from carton and discard all packaging. 

NOTE: 

Save all parts 

bags.

Screw

Handle Grip

Содержание CPF4515

Страница 1: ...Type ___________________________________________ Serial No ______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and unders...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...ou continue to use your accessory When the tank pressure drops to a certain low level the motor will restart automatically The low pressure at which the motor automatically restarts is called cut in p...

Страница 9: ...uts as shown NOTE Place the bolts in the bottom hole of the wheel bracket 2 Tighten securely NOTE The outfit will sit level if the wheels are properly installed The wheels and handle do not provide ad...

Страница 10: ...se if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qual...

Страница 11: ...and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is...

Страница 12: ...the outlet pressure gauge Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure When the desired pressure is reached push knob in to lock in place Univer...

Страница 13: ...automatic reset thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor...

Страница 14: ...ator knob out turn counterclockwise until it stops Push knob in to lock in place 3 Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equippe...

Страница 15: ...n power is on When performing maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any maintenance or repair disconnect power...

Страница 16: ...h the air filter removed A dirty air filter will not allow the compressor pump to operate at full capacity Before you use the compressor pump check the air filter to be sure it is clean and in place I...

Страница 17: ...g a screwdriver carefully push the valve disc up and down NOTE The valve disc should move freely up and down on a spring which holds the valve disc in the closed position if not the check valve needs...

Страница 18: ...connect 8 Reassemble outlet pressure gauge and quick connect Orient outlet pressure gauge to read correctly Tighten connect with wrench Regulator Arrow Regulator Nipple To Replace Regulator 1 Release...

Страница 19: ...e is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weake...

Страница 20: ...tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pre...

Страница 21: ...essor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air...

Страница 22: ...ch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wro...

Страница 23: ...23 ENG A08202 NOTES...

Страница 24: ...be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service call arrangements If the purchaser does no...