22- ENG 

A08202

Regulator will 
not shut off air 
outlet.

Damaged regulator.

Replace.

PROBLEM

CAUSE

CORRECTION

Motor will not 
run.

Fuse blown, circuit breaker 
tripped.

1. Check fuse box for blown 

fuse and replace as 

necessary. Reset circuit 

breaker. Do not use a fuse 

or circuit breaker with 

higher rating than that 

specified for your particular 

branch circuit.

2. Check for proper fuse. You 

should use a time delay 

fuse.

3. Check for low voltage 

conditions and/or proper 

extension cord.

4. Disconnect the other 

electrical appliances from 

circuit or operate the 

compressor on its own 

branch circuit.

Motor overload protection 
switch has tripped.

Let motor cool off and 

overload switch will 

automatically reset.

Tank pressure exceeds 
pressure switch "cut-in" 
pressure.

Motor will start automatically 

when tank pressure drops 

below "cut-in" pressure of 

pressure switch.

Extension cord is wrong 
length or gauge.

Check for proper gauge wire 
and cord length.

Loose electrical connections. Check wiring connection 

inside pressure switch and 
terminal box area.
Have checked by a Trained 
Service Technician.

Check valve stuck open.

Remove and clean, or 
replace.

Possible defective motor or 
starting capacitor.

Have checked by a Trained 

Service Technician.  Do not 

operate the compressor in 

the paint spray area.  See 

flammable vapor warning.

Paint spray on internal motor 
parts.

Bleed the line by pushing the 

lever on the pressure switch 

to the "Off" position; if the 

valve does not open, replace 

switch.

Pressure release valve on 
pressure switch has not 
unloaded head pressure.

Содержание CPF4515

Страница 1: ...Type ___________________________________________ Serial No ______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and unders...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...ou continue to use your accessory When the tank pressure drops to a certain low level the motor will restart automatically The low pressure at which the motor automatically restarts is called cut in p...

Страница 9: ...uts as shown NOTE Place the bolts in the bottom hole of the wheel bracket 2 Tighten securely NOTE The outfit will sit level if the wheels are properly installed The wheels and handle do not provide ad...

Страница 10: ...se if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qual...

Страница 11: ...and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is...

Страница 12: ...the outlet pressure gauge Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure When the desired pressure is reached push knob in to lock in place Univer...

Страница 13: ...automatic reset thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor...

Страница 14: ...ator knob out turn counterclockwise until it stops Push knob in to lock in place 3 Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equippe...

Страница 15: ...n power is on When performing maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any maintenance or repair disconnect power...

Страница 16: ...h the air filter removed A dirty air filter will not allow the compressor pump to operate at full capacity Before you use the compressor pump check the air filter to be sure it is clean and in place I...

Страница 17: ...g a screwdriver carefully push the valve disc up and down NOTE The valve disc should move freely up and down on a spring which holds the valve disc in the closed position if not the check valve needs...

Страница 18: ...connect 8 Reassemble outlet pressure gauge and quick connect Orient outlet pressure gauge to read correctly Tighten connect with wrench Regulator Arrow Regulator Nipple To Replace Regulator 1 Release...

Страница 19: ...e is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weake...

Страница 20: ...tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pre...

Страница 21: ...essor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air...

Страница 22: ...ch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wro...

Страница 23: ...23 ENG A08202 NOTES...

Страница 24: ...be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service call arrangements If the purchaser does no...

Отзывы: