INSTALLATION

GROUNDING INSTRUCTIONS

RISK OF ELECTRICAL SHOCK.  In the event of a short 
circuit, grounding reduces the risk of shock by providing 

an escape wire for the electric current. This air compressor must be 
properly grounded.

The portable air compressor is equipped with a cord having a grounding wire 
with an appropriate grounding plug (see following illustrations).  The plug must 
be used with an outlet that has been installed and grounded in accordance 
with all local codes and ordinances. 
1.  The cord set and plug with this unit contains a grounding pin. This plug 

MUST be used with a grounded outlet. 

IMPORTANT:

 The outlet being used must be installed and grounded in 

accordance with all local codes and ordinances. 
2.  Make sure the outlet being used 

has the same configuration as the 
grounded plug. 

DO NOT USE AN 

ADAPTER. 

See illustration.

3.  Inspect the plug and cord before each 

use.  Do not use if there are signs of 
damage.

4.  If these grounding instructions are not completely understood, or if in 

doubt as to whether the compressor is properly grounded, have the 
installation checked by a qualified electrician.

I

MPROPER GROUNDING CAN RESULT IN ELECTRICAL 

SHOCK.

 

Do not modify the plug provided. If it does not fit the available outlet, a 
correct outlet should be installed by a qualified electrician.
Repairs to the cord set or plug MUST be made by a qualified electrician.

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area. The air 
compressor should be located at least 12" away from the wall or other 
obstructions that will interfere with the flow of air. The air compressor pump 
and shroud are designed to allow for proper cooling. The ventilation openings 
on the compressor are necessary to maintain proper operating temperature. Do 
not place rags or other containers on or near these openings.The air filter must 
be kept clear of obstructions which could reduce air flow to the air compressor. 

Grounding Pin

Grounded 
Outlets 

Plug

Содержание CPF4515

Страница 1: ...Type ___________________________________________ Serial No ______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and unders...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...ou continue to use your accessory When the tank pressure drops to a certain low level the motor will restart automatically The low pressure at which the motor automatically restarts is called cut in p...

Страница 9: ...uts as shown NOTE Place the bolts in the bottom hole of the wheel bracket 2 Tighten securely NOTE The outfit will sit level if the wheels are properly installed The wheels and handle do not provide ad...

Страница 10: ...se if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qual...

Страница 11: ...and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is...

Страница 12: ...the outlet pressure gauge Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure When the desired pressure is reached push knob in to lock in place Univer...

Страница 13: ...automatic reset thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor...

Страница 14: ...ator knob out turn counterclockwise until it stops Push knob in to lock in place 3 Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equippe...

Страница 15: ...n power is on When performing maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any maintenance or repair disconnect power...

Страница 16: ...h the air filter removed A dirty air filter will not allow the compressor pump to operate at full capacity Before you use the compressor pump check the air filter to be sure it is clean and in place I...

Страница 17: ...g a screwdriver carefully push the valve disc up and down NOTE The valve disc should move freely up and down on a spring which holds the valve disc in the closed position if not the check valve needs...

Страница 18: ...connect 8 Reassemble outlet pressure gauge and quick connect Orient outlet pressure gauge to read correctly Tighten connect with wrench Regulator Arrow Regulator Nipple To Replace Regulator 1 Release...

Страница 19: ...e is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weake...

Страница 20: ...tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pre...

Страница 21: ...essor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air...

Страница 22: ...ch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wro...

Страница 23: ...23 ENG A08202 NOTES...

Страница 24: ...be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service call arrangements If the purchaser does no...

Отзывы: