9 - ENG

A09770

ASSEMBLY

Unpacking

1.  Remove unit from carton and discard all packaging. 

IMPORTANT:

 The outlet being used 

must be installed and grounded in 
accordance with all local codes and 
ordinances. 
2.  Make sure the outlet being used 

has the same configuration as 
the grounded plug. DO NOT USE 
AN ADAPTER. See illustration.

3.  Inspect the plug and cord before 

each use.  Do not use if there are 
signs of damage.

4.  If these grounding instructions 

are not completely understood, 
or if in doubt as to whether the 
compressor is properly grounded, 
have the installation checked by 
a qualified electrician.

Risk of Electrical
Shock. IMPROPER 

GROUNDING CAN RESULT IN 
ELECTRICAL SHOCK.
Do not modify the plug provided. If 
it does not fit the available outlet, 
a correct outlet should be installed 
by a qualified electrician.
Repairs to the cord set or plug 
MUST be made by a qualified 
electrician.

GROUNDING INSTRUCTIONS

Risk of Electrical 
Shock.  In the event 

of a short circuit, grounding reduces 
the risk of shock by providing an 
escape wire for the electric current. 
This air compressor must be 
properly grounded.

The portable air compressor is 
equipped with a cord having a 
grounding wire with an appropriate 
grounding plug (see following 
illustrations). 
1.  The cord set and plug with this 

unit contains a grounding pin. 
This plug MUST be used with a 
grounded outlet. 

INSTALLATION

HOW TO SET UP YOUR UNIT

Grounding Pin

Grounded 
Outlets 

Plug

Location of the Air Compressor

• 

Locate the air compressor in a 
clean, dry and well ventilated 
area. 

 

The air compressor should be 
located at least 12" away from 
the wall or other obstructions that 
will interfere with the flow of air. 

 

The air compressor pump and 
shroud are designed to allow for 
proper cooling. The ventilation 
openings on the compressor are 
necessary to maintain proper 
operating temperature. Do not 
place rags or other containers on 
or near these openings.

Lubrication and Oil

This unit needs no lubrication or oiling.

Содержание CFFC350C

Страница 1: ...__________________________ Serial No ______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instruction...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...s is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor au...

Страница 9: ...ian GROUNDING INSTRUCTIONS Risk of Electrical Shock In the event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be...

Страница 10: ...OT USE 14 OR 16 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit...

Страница 11: ...mp not shown Compresses air into the air tank Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet Description of Operation Become f...

Страница 12: ...art after the motor cools 12 ENG A09770 Check Valve Before First Start Up Risk of Unsafe Operation Serious damage may result if the following break in instructions are not closely followed This proced...

Страница 13: ...t valves Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or disconn...

Страница 14: ...sion 1 Before starting compressor pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the s...

Страница 15: ...D ADJUSTMENTS Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or di...

Страница 16: ...nnect Orient outlet pressure gauge to read correctly Tighten connect with wrench To Replace Regulator 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug uni...

Страница 17: ...is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will co...

Страница 18: ...tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pre...

Страница 19: ...essor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air...

Страница 20: ...ch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wro...

Страница 21: ...21 ENG A09770 NOTES...

Страница 22: ...purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service c...

Отзывы: