Before Each Start-Up:

1.  Place On/Auto/Off lever  to "Off".
2.  Turn the regulator knob counter-

clockwise to set the outlet 
pressure to zero.

3.  Attach hose and accessories. 

NOTE:

 The hose or accessory will 

require a quick connect plug if the 
air outlet is equipped with a quick 
connect socket. 

Risk of Bursting. 

Too much air 

pressure causes a hazardous 

risk of bursting. Check the 

manufacturer’s maximum pressure 

rating for air tools and accessories. 

The regulator outlet pressure 

must never exceed the maximum 
pressure rating.

MAINTENANCE

Customer Responsibilities

Daily 

or after 

each 

use

Before 
each 
use

Every 
100 
hours

Yearly

1

1- more frequent in dusty or humid conditions

Check Safety Valve
Drain Tank
Air Filter

To ensure efficient operation and 
longer life of the air compressor, 
a routine maintenance schedule 

Air compressor pump intake 
and exhaust valves

Risk of Unsafe 

Operation. Unit 

cycles automatically when power 

is on. When servicing, you may 

be exposed to voltage sources, 

compressed air, or moving parts. 

Before servicing unit unplug or 

disconnect electrical supply to 

the air compressor, bleed tank 

of pressure, and allow the air 

compressor to cool.

should be prepared and followed. The 
above routine maintenance schedule 
is geared to an air compressor in a 
normal working environment operating 
on a daily basis. If necessary, the 
schedule should be modified to 
suit the conditions under which 
your air compressor is used. The 
modifications will depend upon 
the hours of operation and the 
working environment. Compressors 
in an extremely dirty and/or hostile 
environment will require a greater 
frequency of all maintenance checks.

How to Start:

1.  Turn the On/Auto/Off lever to "On/

Auto" and allow tank pressure 
to build.  Motor will stop when 
tank pressure reaches "cut-out" 
pressure.

2.  Turn regulator knob clockwise to 

increase pressure and stop when 
desired pressure is reached.

The compressor is ready for use.

Содержание CFFC350C

Страница 1: ...__________________________ Serial No ______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instruction...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...s is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor au...

Страница 9: ...ian GROUNDING INSTRUCTIONS Risk of Electrical Shock In the event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be...

Страница 10: ...OT USE 14 OR 16 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit...

Страница 11: ...mp not shown Compresses air into the air tank Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet Description of Operation Become f...

Страница 12: ...art after the motor cools 12 ENG A09770 Check Valve Before First Start Up Risk of Unsafe Operation Serious damage may result if the following break in instructions are not closely followed This proced...

Страница 13: ...t valves Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or disconn...

Страница 14: ...sion 1 Before starting compressor pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the s...

Страница 15: ...D ADJUSTMENTS Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or di...

Страница 16: ...nnect Orient outlet pressure gauge to read correctly Tighten connect with wrench To Replace Regulator 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug uni...

Страница 17: ...is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will co...

Страница 18: ...tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pre...

Страница 19: ...essor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air...

Страница 20: ...ch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wro...

Страница 21: ...21 ENG A09770 NOTES...

Страница 22: ...purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service c...

Отзывы: