Porter-Cable CFFC350C Скачать руководство пользователя страница 14

14 - ENG

A09770

To Drain Tank

1.  Set the On/Auto/Off lever to "Off" 

and unplug unit.

2.  Turn the regulator knob counter-

clockwise to set the outlet 
pressure to zero.

3.  Remove the air tool or accessory.
4.  Pull ring on safety valve allowing 

air to bleed from the tank until 
tank pressure is approximately 
20 psi. Release safety valve ring.

5.  Drain water from air tank by 

opening drain valve (counter-
clockwise) on bottom of tank.

Risk of Bursting. 
Water will 

condense in the air tank. If not 
drained, water will corrode and 
weaken the air tank causing a risk 
of air tank rupture.

6.  After the water has been drained, 

close the drain valve (clockwise).  
The air compressor can now be 
stored.

NOTE

: If drain valve is plugged, 

release all air pressure.  The valve 
can then be removed, cleaned, the 
reinstalled.

To Check Safety Valve

Risk of Bursting. 

If the safety valve 

does not work properly, over-

pressurization may occur, causing 

air tank rupture or an explosion. 

1.  Before starting compressor, pull 

the ring on the safety valve to 

make sure that the safety valve 

operates freely. If the valve 

is stuck or does not operate  

smoothly, it must be replaced 

with the same type of  valve. 

Air Compressor Pump Intake 
and Exhaust Valves

Once a year have a Trained Service 
Technician check the air compressor 
pump intake and exhaust valves.

Air Filter Inspection and 
Replacement

Hot surfaces.  

Risk of burn. 

Compres-sor heads are exposed 

when filter cover is removed.  

Allow compressor to cool prior to 

servicing.

Keep the air filter 
clean at all times. 

Do not operate the air compressor 
with the air filter removed.

A dirty air filter will not allow the 
compressor pump to operate at 
full capacity. Before you use the 
compressor pump, check the air filter 
to be sure it is clean and in place.
If it is dirty, replace it with a new filter. 
1.   Remove the air filter cover.
2.  Remove the air filter from filter 

cover.

3.  Place new air filter into filter 

cover. Refer to the "Repair Parts" 
for the correct part number.

4.  Replace air filter cover and lock 

into place.

NOTE:

 See "Operation" section for 

the location of controls.

Содержание CFFC350C

Страница 1: ...__________________________ Serial No ______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instruction...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...s is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor au...

Страница 9: ...ian GROUNDING INSTRUCTIONS Risk of Electrical Shock In the event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be...

Страница 10: ...OT USE 14 OR 16 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit...

Страница 11: ...mp not shown Compresses air into the air tank Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet Description of Operation Become f...

Страница 12: ...art after the motor cools 12 ENG A09770 Check Valve Before First Start Up Risk of Unsafe Operation Serious damage may result if the following break in instructions are not closely followed This proced...

Страница 13: ...t valves Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or disconn...

Страница 14: ...sion 1 Before starting compressor pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the s...

Страница 15: ...D ADJUSTMENTS Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or di...

Страница 16: ...nnect Orient outlet pressure gauge to read correctly Tighten connect with wrench To Replace Regulator 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug uni...

Страница 17: ...is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will co...

Страница 18: ...tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pre...

Страница 19: ...essor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air...

Страница 20: ...ch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wro...

Страница 21: ...21 ENG A09770 NOTES...

Страница 22: ...purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service c...

Отзывы: