background image

Remove product from packaging

Position on level surface

Fill tank or attach water hose*

1

2

3

QUICK SETUP

Plug into appropriate outlet

Fill the tank, then turn on the pump switch and the fan

For setup, Kuul Comfort

TM 

evaporative media should 

appear wet before starting the fan. Check the water 
gauge to monitor water level in tank. The water 
adjustment valve on each portable evaporative cooler 

is set at max flow. However, ensure the knob is turned 

completely to the right before use. Turn to the left to 

increase water flow. If entrainment occurs - water is 

spitting from the front of the product - use the valve to 

decrease the water flow until entrainment ceases. 

4

5

Your Portacool portable evaporative cooler is meant to 

be used in an open-air environment, such as a patio. 

If you plan to use your evaporative cooler in a more 

closed environment – such as a garage, sunroom or 

barn – you must provide adequate ambient airflow to 

ensure your evaporative cooler works at its highest 

efficiency. When using in a semi-closed environment, 

be sure to leave a door or window open to allow for the 

proper amount of airflow.   

6

Ensure proper airflow is available 

*Maximum water pressure 50 psi/345 kPa

Содержание CYCLONE 110

Страница 1: ...PORTACOOL CYCLONE OWNER S MANUAL PACCY110 PACCY120 PACCY130 PACCY140 PACCY160 Applies to all 120 and 240V products for global configurations...

Страница 2: ...the left to increase water flow If entrainment occurs water is spitting from the front of the product use the valve to decrease the water flow until entrainment ceases 4 5 Your Portacool portable evap...

Страница 3: ...e it is functioning properly Remove the plug from the electrical receptacle by pulling on the plug not the power cord Operation near open flames or sparks is not recommended If operating near open fla...

Страница 4: ...10 Drain located in back Recessed casters Fill door Adjustable louvers Control panel Water Level Indicator Hose connection Power cord with GFCI OVERVIEW Kuul Comfort evaporative media Water adjustment...

Страница 5: ...NE 120 OVERVIEW Drain located in back Casters Fill door Adjustable louvers Control panel Water Level Indicator Hose connection Power cord with GFCI Kuul Comfort evaporative media Water adjustment valv...

Страница 6: ...NE 130 OVERVIEW Drain located in back Casters Fill door Adjustable louvers Control panel Water Level Indicator Hose connection Power cord with GFCI Kuul Comfort evaporative media Water adjustment valv...

Страница 7: ...PORTACOOL CYCLONE 140 OVERVIEW Drain located on back Casters Control panel Water Level Indicator Hose connection Power cord with GFCI Kuul Comfort evaporative media Water adjustment valve Serial plate...

Страница 8: ...ORTACOOL CYCLONE 160 OVERVIEW Drain located on bottom Casters Control panel Water Level Indicator Hose connection Power cord with GFCI Kuul Comfort evaporative media Water adjustment valve Serial plat...

Страница 9: ...very low leakage currents Portacool Cyclone models PACCY160 PACCY140 PACCY130 PACCY120 and PACCY110 use a GFCI which is built into the power cord The GFCI on these models will automatically reset when...

Страница 10: ...and alert the user that the pump has shut off This light may cycle on and off for a few minutes to draw attention to the low water condition as it tries to exhaust the remaining water In order to res...

Страница 11: ...G THE WATER FLOW Once the tank is full of water flip the pump switch into the on position The water level in the tank may drop suddenly and restart the flow of supply water This is a normal condition...

Страница 12: ...l evaporative media in correct airflow direction referring to the label on the Kuul evaporative media If conditions such as hard water warrant Portacool Hard Water Treatment can be purchased at www po...

Страница 13: ...2 Replace motor 1 Move evaporative cooler at least three feet from the wall 2 Replace fan motor 3 Replace capacitor 1 Replace float valve 2 Tighten plug 1 Check and tighten where needed 2 Inspect and...

Страница 14: ...agnant water in tank 2 Kuul evaporative media is mildewed or clogged 1 Too much water delivered to Kuul evaporative media 2 Leaking hose REMEDY 1 Drain flush and clean tank 2 Replace Kuul evaporative...

Страница 15: ...ble If the Equipment anIf the Equipment and or its original component parts develop a defect covered by this limited warranty within the applicable time periods described above the same may be repaire...

Страница 16: ...e following components are included with your Portacool Cyclone series product For complete warranty information and limitations please see Warranty page Beyond these aspects of Portacool Protect we a...

Страница 17: ...uld be below 75 However Portacool evaporative coolers will reduce the temperature in almost any environment making it more comfortable Q How often should my Kuul ComfortTM evaporative media be replace...

Страница 18: ...a safe place to prevent damage while out of the evaporative cooler Once all the Kuul Comfort evaporative media has been removed you should have access to the inside of the evaporative cooler and inter...

Страница 19: ...00A PARCTLCYC00A PARCTLCY140A PARCTLCY160A COVER PARCVRCYC06 PAC CVR C2 PAC CVR 02 PARCVRCY1400 PARCVRC16000 HARD WATER TREATMENT PARPACHWTB00 PARPACHWTB00 PARPACHWTB00 PARPACHWTB00 PARPACHWTB00 Addit...

Страница 20: ...75935 936 598 5651 www portacool com www thekuuleffect com The manual is available in other languages To download a digital copy please visit www portacool com El manual est disponible en otros idiom...

Отзывы: