background image

-   2   -

7 3 0 1 3 7 5 - 1 0 0   R e v .   B

6

7

INSTALL TOILET SEAT 

Install toilet seat in accordance with manufacturer's directions.

8a

8b

Before continuing, determine the type of water supply connection you have from the chart 
below and use the appropriate assembly parts required to properly reconnect the water supply. 
DO NOT use plumber's putty to seal these fittings.

CAUTION: DO NOT USE 
CONE WASHER WITH 
PLASTIC SUPPLY LINE.

These parts must be used as 
illustrated to insure water-tight 
connection. Use of existing 
coupling nut may result in 
water leakage. Water supply 
tube or pipe must extend at 
least 1/2" inside threaded 
shank of valve (does not 
apply to flanged tubing).

Use existing 
coupling nut 
and washer.

Use existing spiral cone 
washer. Fluidmaster 
cone washer may not 
seal completely on 
spiral type supply line.

Captive cone washers 
already included. No 
additional washers needed.

CAUTION: Overtightening of 
LOCK NUT or COUPLING NUT 
could result in breakage and 
potential flooding.

METAL/COPPER

FLARED TUBING

METAL FLANGED

TUBING

METAL SPIRAL

TUBING

VINYL/BRAIDED

CONNECTOR

LOCK NUT

LOCK NUT

LOCK NUT

LOCK NUT

COUPLING
NUT

COUPLING
NUT

EXISTING
COUPLING
NUT

COUPLING
NUT

WATER
SHUT-OFF

WATER
SHUT-OFF

WATER
SHUT-OFF

WATER
SHUT-OFF

CONE
WASHER

EXISTING
CONE
WASHER

EXISTING
WASHER

With correct washers in place (see Step 8a), 
tighten COUPLING NUT 1/4 turn beyond 
hand tight. 

DO NOT OVERTIGHTEN.

9

10

If bowl fails to siphon, an 
adjustment may be required with 
the lift chain. Simply remove the 
bead chain from the retainment 
clip (see Fig. 9a) and take up 
slack on the chain, and reinsert 
on lift rod.  Make sure the chain 
is not too taut.

Adjust water level to level 
indicated on tank by adjusting 
float cup. Adjust water to 
desired level by squeezing 
water level adjustment clip and 
moving FLOAT CUP up or 
down along stainless steel link.

ADJUSTMENTS: 
Turn supply on.

a.

b.

Turn on water supply. 
Submerge the FLOAT 
CUP under the water for 
30 seconds. Adjust the 
water to desired level by 
turning WATER LEVEL 
ADJUSTMENT ROD 
and moving FLOAT 
CUP up or down.

a.  Position toilet squarely to wall and, with a rocking motion, press bowl 

down fully on wax ring and flange. 

 

Alternately tighten nuts until toilet is firmly seated on floor.

CAUTION: 

DO NOT OVERTIGHTEN NUTS OR    

 

    BASE MAY BE DAMAGED!

b.  Install bolt covers:

1.     Make sure that the bolt cover area on the toilet is clean and 

dry (see figure). Use a dry piece of cloth or soap and water
if needed.

2.     Take plastic bolt cover and peel the brown protective film off 

on both ends. The adhesive part is now visible and ready to

 be placed on the toilet (see figure).

3.     Gently place the bolt cover on the toilet area (see picture) and if
        everything is aligned, push bolt cover firmly so it remains in place.

4.     If not aligned, you can still take it off and put it back so it is aligned.
5.     Repeat Step 3 for second bolt cover which is to be placed on opposite side of the toilet.
6.     After 24 hours, the bolt cover adhesive has completely set off and if needed, you can remove/replace 
        as needed. The dual lock technology is now in place.

 
c.  Smooth off the bead of sealant around base. Remove excess sealant.

!

INSTALL TOILET

TANK
LEVER

TOP OF
OVERFLOW

REFILL
TUBE

WATER LEVEL 

ADJUSTMENT 

ROD

TOP

ARM

NIPPLE

Diagram 1

PARTS FOR WATER
CONNECTION
(SEE STEP 8)

CONE WASHER

THREADED
SHANK

SHANK
WASHER

COUPLING NUT
(HAND TIGHT ONLY)

FLOAT

CUP

CRITICAL LEVEL

MARK ("C.L.")

MUST BE

1" ABOVE

OVERFLOW PIPE

LOCK NUT

Fig. 9a

VALVE

BODY

FILL 

VALVE

ADJUSTABLE
HEIGHT

CLOSET

BOLT

NUT

BOLT COVER

BOLTS

CLOSET FLANGE

Peel both protective films off 
and stick bolt cover to toilet.

Back Side

Front Side

BOLT COVER