always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number

Maximum Nodes

Description

1

10

Lifeline

2

10

Door Lock Control

3

10

Ring Button Control

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a
primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The
following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a
controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by
pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

Turn into Management Mode, hit button 1 and confirm with * (Star Key)

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is
terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be
turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention:

 Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous

network.

Turn into Management Mode, hit button 2 and confirm with * (Star Key)

Shift of Primary Controller Role

The device can hand over its primary role to another controller and become secondary controller.

Turn into Management Mode, hit button 3 and confirm with * (Star Key)

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT:

 Controllers may only allow configuring signed values. In order to set values in the range 128...255 the value sent in the application shall be the

desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 1: Door Lock Automatic Secure Timeout

After this time a CLOSE command is sent to the controlled door lock. On default no CLOSE command is sent assuming that the strike lock has its own timeout set 

Size: 1 Byte, Default Value: 0

Setting

Description

0 - 127

Seconds

Parameter 2: Ring Button Press Basic Command OFF Timeout

After this time the Door Bell will receive an OF command regardless of the actuall button is pressed or not 

Size: 1 Byte, Default Value: 3

Setting

Description

3 - 127

Seconds

Parameter 3: Ring Button ON Command

This value is sent into Association Group 3 when the door bell button is pressed. 

Size: 1 Byte, Default Value: 255

Setting

Description

0 - 99

Basic Set Command Value

255

Basic Set Command Value

Parameter 4: Ring Button OFF Command

This value is sent into Association Group 3 when the door bell button is released or the timeout has reached. 

Size: 1 Byte, Default Value: 0