Security

Controlled Command Classes

Basic

Central Scene

Switch Multilevel

Switch All

Scene Activation

Multi Channel

Explanation of Z-Wave specific terms

Controller

 — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall

controllers.

Slave

 — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.

Primary Controller

 — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.

Inclusion

 — is the process of adding new Z-Wave devices into a network.

Exclusion

 — is the process of removing Z-Wave devices from the network.

Association

 — is a control relationship between a controlling device and a controlled device.

Wakeup Notification

 — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.

Node Information Frame

 — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.

Support and Contact

Should you encounter any problem, please give us an opportunity to address it before returning this product. Most questions regarding Z-Wave wireless
communication standard can be answered through the international users community such as www.z-wave.info and others. If your question can’t be answered
there, please use www.popp.eu/support or contact us by email: [email protected]

While the information in this manual has been compiled with great care, it may not be deemed an assurance of product characteristics. Popp & Co. shall be liable
only to the degree specified in the terms of sale and delivery. The reproduction and distribution of the documentation and software supplied with this product and
the use of its contents is subject to written authorization from Popp & Co. We reserve the right to make any alterations that arise as the result of technical
development.

Phone: +49 (0) 40 537 98 13 339 
eMail: [email protected]
Web: www.popp.eu

Declaration of Conformity

Popp hereby declares this device complies with the essential requirements and other relevant prescriptions of Directive 1999/5/EC R&TTE. The
complete CE declaration can be found on: 

www.popp.eu/ce

.

All questions regarding this declaration of conformity can be directed to the following address: Popp c/o BID GmbH, Neuer Wall 63, 20148
Hamburg, Germany

Disposal Guidelines

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for
information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can
leak into the groundwater and get into the food chain, damaging health and well-being.

Содержание POPE009204

Страница 1: ...evices will turn the button group into Basic control value 2 All con guration values can be changed if needed When KFOB is primary controller the very rst device included will be automatically put int...

Страница 2: ...atch the position of the white rubber and make sure the silver buttons t exactly into the nipples of the rubber The device can be operated in two different modes the operation mode and the management...

Страница 3: ...is process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion respective inclusion mode Inclusion and Exclusion i...

Страница 4: ...irect Control of associated devices with On Off Dim commands and implements communication patterns 6 and 7 Please turn the button mode to separate to allow different a scene ID on every button Scene A...

Страница 5: ...e called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will recei...

Страница 6: ...allow con guring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example To set a parameter to 200 it may be neede...

Страница 7: ...all 4 Send scenes 5 Send precon gured scenes 6 Send precon gured scenes 7 Control door lock 8 Central scene to gateway Parameter 14 Command to control Group D This parameter de nes the command to be s...

Страница 8: ...To same node as Wake Up Noti cation 2 Broadcast to neighbors Technical Data Dimensions 30x55x15 mm Weight 32 gr Hardware Platform ZM5202 EAN 0019962009204 IP Class IP 20 Battery Type 1 CR2032 Device T...

Страница 9: ...national users community such as www z wave info and others If your question can t be answered there please use www popp eu support or contact us by email info popp eu While the information in this ma...

Отзывы: