Popp POPE009204 Скачать руководство пользователя страница 8

Setting

Description

0

No

1

Yes

Parameter 25: Blocks wake up even when Wake Up Interval is set

If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery. 

Size: 1 Byte, Default Value: 0

Setting

Description

0

Wake up is blocked

1

Wake up is possible if configured accordingly

Parameter 30: Send unsolicited battery report on Wake Up

 
Size: 1 Byte, Default Value: 1

Setting

Description

0

No

1

To same node as Wake Up Notification

2

Broadcast to neighbors

Technical Data

Dimensions

30x55x15 mm

Weight

32 gr

Hardware Platform

ZM5202

EAN

0019962009204

IP Class

IP 20

Battery Type

1 * CR2032

Device Type

Simple Remote Control

Generic Device Class

Portable Controller

Network Operation

Portable Controller

Firmware Version

01.00

Z-Wave Version

03.63

Certification ID

ZC10-15050016

Z-Wave Product Id

0115.0100.0103

Supported Command Classes

Scene Controller Conf

Association Grp Info

Device Reset Locally

Central Scene

Zwaveplus Info

Configuration

Manufacturer Specific

Powerlevel

Battery

Wake Up

Association

Version

Multi Channel Association

Содержание POPE009204

Страница 1: ...evices will turn the button group into Basic control value 2 All con guration values can be changed if needed When KFOB is primary controller the very rst device included will be automatically put int...

Страница 2: ...atch the position of the white rubber and make sure the silver buttons t exactly into the nipples of the rubber The device can be operated in two different modes the operation mode and the management...

Страница 3: ...is process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion respective inclusion mode Inclusion and Exclusion i...

Страница 4: ...irect Control of associated devices with On Off Dim commands and implements communication patterns 6 and 7 Please turn the button mode to separate to allow different a scene ID on every button Scene A...

Страница 5: ...e called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will recei...

Страница 6: ...allow con guring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example To set a parameter to 200 it may be neede...

Страница 7: ...all 4 Send scenes 5 Send precon gured scenes 6 Send precon gured scenes 7 Control door lock 8 Central scene to gateway Parameter 14 Command to control Group D This parameter de nes the command to be s...

Страница 8: ...To same node as Wake Up Noti cation 2 Broadcast to neighbors Technical Data Dimensions 30x55x15 mm Weight 32 gr Hardware Platform ZM5202 EAN 0019962009204 IP Class IP 20 Battery Type 1 CR2032 Device T...

Страница 9: ...national users community such as www z wave info and others If your question can t be answered there please use www popp eu support or contact us by email info popp eu While the information in this ma...

Отзывы: