Dissolving The Salt
Before attempting to operate the Enduro Chlor cell, the salt must be allowed to fully
dissolve in the pool water. This is best achieved (after allowing sufficient time for the
glue on the pipe fittings to set properly) by running the filter pump without the cell
operating for 24 hours to circulate the water.
To assist the dissolving of the salt, regularly brush the floor of the pool with a pool
broom until the salt has dissolved.
When The Salt Has Dissolved
Turn on the Enduro Chlor. The Output Salt Monitor should read in the NORMAL range
i.e. green range
.
Your Enduro Chlor is now generating chlorine!
Should the Salt Monitor read in the yellow region, do not be concerned, just allow the
system to run for another 24-48 hours. If the display continues to give a low reading
after this period then add more salt gradually over a period of days until the display
reads high in the Normal band (i.e. green). Continue brushing floor of pool until the
additional salt has dissolved.
SETTINGS AND CONTROLS
POWER PACK OPERATION
CHLORINE CONTROL — all models
Because your Enduro Chlor has been designed to operate over a wide range of salt
levels, water temperature, running time, etc., a Chlorine Control has been provided on
self clean models to compensate for these variations.
When first starting the unit and where maximum chlorine production is needed the
output should be set to maximum.
When first starting the unit and where maximum chlorine production is needed the
control knob should be rotated fully clockwise so the Salt Monitor is indicating
maximum on the Chlorine Output scale or as high as prevailing conditions will allow.
The Chlorine Control knob on self clean models can be turned fully clockwise if higher
salt levels are used without the risk of damage occurring, due to the incorporation of
electronic output limiting.
SALT MONITOR
The output Salt Monitor has been provided to allow monitoring of the current passing
through the electrolytic cell to allow you to gauge the operation of the cell and the
chlorine production. This assists in determining the condition of the electrolytic cell.
It also provides a simple means of indicating the salt level of the pool water.
The self clean models will indicate low salt or dirty cell if the status light is red.
7
PLR183 _Endchlor MAN-txt 17/7/06 12:20 PM Page 7