background image

© 2017 PoolPak LLC. All rights reserved.

Page 5

MPK with CommandPak

 Control System BACnet /IP User’s Guide

OBJECT 

TYPE

READ/ 

WRITE

OBJECT 

INSTANCE

OBJECT NAME

DESCRIPTION

UNITS

AV

R

1003

CPR2_xwiActiveFaultCode

Cmpr2 Fault Code

See below

AV

R

1004

CPR2_xwiMode

Cmpr2 Actual Mode

See below

AV

R

1005

CPR3_xwiActiveFaultCode

Cmpr3 Fault Code

See below

AV

R

1006

CPR3_xwiMode

Cmpr3 Actual Mode

See below

AV

W

1007

twiSetInpEvtMinMixBoxPos

Event Min Mix Box Pos Setpoint

%

AV

W

1008

twiSetInpMaxMixBoxPos

Max Mix Box Pos Setpoint

%

AV

W

1009

twiSetInpMinMixBoxPos

Min Mix Box Pos Setpoint

%

AV

W

1010

twiSetInpPool1WtrTmp

Pool1 Water Temp Setpoint

°F

AV

W

1011

twiSetInpPool2WtrTmp

Pool2 Water Temp Setpoint

°F

AV

W

1012

twiSetInpPurMixBoxPos

Purge Mode Mix Box Setpoint

%

AV

W

1013

twiSetInpRtnAirRelHum

Return Air RH Setpoint

%

AV

W

1014

twiSetInpRtnAirTmp

Return Air Temp Setpoint

°F

AV

R

1015

xwiAuxAirCoolStgRqd

Aux Air Cool Requested (Rqd)

Stages

AV

R

1016

xwiAuxAirHeatStgRqd

Aux Air Heat Stages Rqd

Stages

AV

R

1017

xwiCpr1ModeReq

Cmpr1 Mode Requested

Stages

AV

R

1018

xwiCpr2ModeReq

Cmpr2 Mode Requested

Stages

AV

R

1019

xwiCpr3ModeReq

Cmpr3 Mode Requested

Stages

AV

R

1020

xwiDehStgRqd

Dehumidification Stages Rqd

Stages

AV

R

1021

xwiHeatCoolStgRqd

Heat/Cool Stages Rqd

Stages

AV

R

1022

xwiLastUnitGnlFltCode

Last Unit Fault Code

See below

AV

R

1023

xwiSenGnlFltCode

Sensor Fault Code

See below

AV

R

1024

xwiUnitGnlFltCode

Unit Fault Code

See below

BV

R

1

xbAlarm_DO

Alarm Output

on/off

BV

R

2

xbAuxAirCool1_DO

Aux Cool 1 Output

on/off

BV

R

3

xbAuxAirCool2_DO

Aux Cool 2 Output

on/off

BV

R

4

xbAuxAirCool3_DO

Aux Cool 3 Output

on/off

BV

R

5

xbAuxAirHeat1_DO

Aux Air Heat 1 Output

on/off

BV

R

6

xbAuxAirHeat2_DO

Aux Air Heat 2 Output

on/off

BV

R

7

xbAuxAirHeat3_DO

Aux Air Heat 3 Output

on/off

BV

W

8

xbBASForceNoPurMod

Force NoPurge Mode

on/off

BV

W

9

xbBASForceOccupied

Force Occupied

on/off

BV

W

10

xbBASForcePurMod

Force Purge Mode

on/off

BV

W

11

xbBASForceUnoccupied

Force Unoccupied

on/off

BV

R

12

xbExhFan_DO

Exhaust Fan Output

on/off

BV

R

13

xbOccupied

Occupied Mode

on/off

BV

R

14

xbPool1AuxWtrHeat_DO

Pool1 Aux Heat Output

on/off

BV

R

15

xbPool2AuxWtrHeat_DO

Pool2 Aux Heat Output

on/off

— BACnet Points List continued

Содержание MPK series

Страница 1: ...DOCUMENT SVW07 MPKBACNIP 20171020 UPDATED OCTOBER 2017 PoolPak MPK with CommandPak Control System CPCS BACnet IP User s Guide...

Страница 2: ...advanced password of 9995 then press Enter 6 Use the arrow keys to scroll down to BAS Interface then press Enter 7 Press the Enter key to move the cursor to different fields Use the arrow keys to chan...

Страница 3: ...the following address in a web browser http IP Address config where IP Address is the address assigned to the card manually or through a DHCP server The computer used must be on the same subnet as th...

Страница 4: ...side Air RH AV R 14 xwfOutAirTmp Outside Air Temperature C AV R 15 xwfOutAirVol Outside Air Volume CFM AV R 16 xwfOutDprFbk Outside Air Damper Position AV R 17 xwfPool1WtrTmp Pool1 Water Temperature C...

Страница 5: ...1ModeReq Cmpr1 Mode Requested Stages AV R 1018 xwiCpr2ModeReq Cmpr2 Mode Requested Stages AV R 1019 xwiCpr3ModeReq Cmpr3 Mode Requested Stages AV R 1020 xwiDehStgRqd Dehumidification Stages Rqd Stages...

Страница 6: ...Modes Requested are enumerated values indicating the operation mode of the corresponding compressor system The present value for these objects can be decoded as follows 0 Compressor Off 1 Air Heating...

Страница 7: ...ressure drop UNIT FAULT CODE AND LAST UNIT FAULT CODE XWIUNITGNLFLTCODE AV1022 and AV1024 are enumerated values indicating a general fault condition for the unit The last fault AV1022 indicates the mo...

Страница 8: ...resented by integer values in degrees Fahrenheit CONTROLLING OCCUPANCY MODE The BAS can control the dehumidifier s Purge mode directly This control overrides all internal schedules and controls except...

Страница 9: ...uested set point change is outside of the acceptable range Select set points based on the acceptable range 3491 Industrial Drive York Pennsylvania 17402 USA 800 959 7725 Fax 717 757 5085 2017 PoolPak...