WiFi Setup (Configuration):
Displays a list of available networks with the strongest signal listed first.
Tap on the name to select the network then type in the password using
the on screen keyboard. Use the Test button to confirm the connection
and press the Save button to set the network.
Lock (Unlock):
Locks or Unlocks the Latham Mesh Network. When the network is
unlocked, other unlocked devices will automatically connect to each
other. Locking the network will assign the connected devices to each
other and not allow new devices to connect. To add new devices, unlock
the primary device and the newly added unlocked device will connect.
The network will automatically lock after 2 hours.
Device Setup:
The Device Setup menu is where you
configure what the device is connected to
and how it shows up on the mesh.
Device Setup:
Will bring up a list of connected nodes that
can be configured. The current device will
be the first listed. After selecting a device
more options will be displayed. Enable
Connection should be
enabled
if the
device is wired to a pool cover motor or
pool cover control board. If the device is
not wired to a cover and is functioning as
a remote control, Enable Connection
should be set to
disabled
. Device type
should be set to
Low voltage
if this is
connected to a 920 control board through
low voltage wiring. In any other
configuration this should be set to
High voltage
. Name will set the name
displayed on both this device and the mesh. Cover Direction will assign
a default open direction. Changing this setting will reverse the direction
for open and close. Cover Limit: configures which magnet side is
assigned to stop the cover. Changing this will reverse the magnet side
for both cover directions.
Assign Main:
This setting will assign which device on the
mesh is the default or main for this device.
The main device will be the cover listed
after unlocking.
Maintenance:
The maintenance menu lists configuration options and tools useful to an installer or service
technician.
Calibrate Pool:
Is used to assign how long a cover takes to fully open and close while also setting values
for current limits. After selecting a device to operate, the calibration wizard will start and
guide the installer through the process. Step 1) the cover is fully opened to set a starting
point for the process. For step 2) the cover is fully closed and both operation time and
average current are logged. In step 3) the cover is fully opened while operation time and
average current are logged for this direction. After step 3 the results are displayed and they
can either be saved to the device or the process can be restarted.
1) Lock Screen
a) Service Screen
b) Select Cover Screen
i) Cover Operation Screen (Main device configured)
ii) Set Default Cover (Main device not configured)
iii) Other Covers
iv) Setup
(1) Set Passwords
(2) User Settings
(a) Key Beep
(b) Touchpad Timeout
(c) Screen Brightness
(d) Set Time
(i) Hour, Minute, Second
(ii) Month, Day, Year
(iii) Time Zone
(iv) Use Internet Time
(3) WiFi Setup
(a) WiFi Setup
(b) Lock or Unlock Network
(4) Device Setup*
(a) Device Setup*
(i) Enable connection
(ii) Connection Type
(iii) Name
(iv) Cover Direction
(v) Cover Limit
(b) Assign Main*
(5) Maintenance*
(a) Calibrate Pool*
(i) Uncover
(ii) Cover
(iii) Uncover
(iv) Confirm settings
(b) Current Limits*
(i) Select cover
(c) Edit Service Screen*
(i) Company Name
(ii) Telephone
(iii) Logo
(d) Reboot
(e) Force Secondary
(f) Reset Factory Defaults*
(i) Confirm Screen
v) Lock
* Menu option only visible for maintenance user
Cover Maintenance
Calibrate Pool
Current Limits
Edit Service Screen
Reboot
Force Secondary
Reset Factory Defaults
BACK
Device Setup
Secondary-XXXXX
XXX.XXX.XX.X
Enabled
High Voltage
Enter Name
Default
Keyboard
Done
Cancel
Enable Connection:
Connection Type:
Name:
Cover Direction: