POOL Latham Скачать руководство пользователя страница 7

 

L0311 Rev 3 6-21  

 

 

© Latham Pool Products, Inc. 2021. All rights reserved.

  

 

 

 

Page 7 of 9 

Standard Setup Procedure (cont.):

 

Over The Air (OTA) Update:

 

1.  On your device with the update file, open the list of WiFi networks. Connect to the Touch 

Controller

s WiFi Network 

a)  The Touch Controller network will be listed as a 

Latham-ABCDEF

” 

where ABCDEF 

will be a letter number combination specific to your device. 

b)  The Password for the network will be 

“59915991”

 

2.  Open a web browser and type in the IP address of your primary touch controller. 

a.  To find the IP address log into the touch controller under the service code and enter the Setup menu. 
b.  Enter the Device Setup menu then enter Device Setup. The IP address will be displayed on the top of the 

screen. (ex. 10.100.10.1). 

3.  Click the Browse

… 

button and navigate to the update file saved on your 

device.  

4.  Select the Update button to begin the update. The update will take up to 2 

minutes, do not attempt to refresh the connection or click additional 
buttons. This could lead to device issues or disturb the update process.  

5.  After a successful update the message 

Update Success! Rebooting

…” 

will display. 

6.  The Touch Controller will reboot into updated firmware. 

Menu structure:

 

Lock Screen:

 

The Touch Controller will default to this screen on restarts and after screen 
timeouts. The device can be unlocked using one of 4 user passwords or the 
maintenance password. By default, User 1 will be 

“1234” 

and the 

maintenance code will always be 

“5991.” 

The service icon will display 

contact information set by the installer which a homeowner can use in case 
of issues. 

Select Cover Screen:

 

From this screen you can either select a cover to operate or select Setup to go further into available options. A large 
button will either select the default cover or move to a screen to set the default cover depending on if one is configured. 
The Other Covers button will allow the user to select other covers in the network to operate if available. 

Cover Operation Screen:

 

Allows operation of a pool cover via the Open and Close buttons. For safety, the cover will only operate when an 
operation button is held. 

The top bar will display the cover selected in addition to any notifications during operation. This screen will timeout by 
default with 20 seconds of inactivity (max allowable).  

Set Passwords:

 

Passwords to unlock the device are configured on this screen. User 1 and Maintenance User are able to modify all 4 
passwords. All other users can only modify their own password and name. 

To modify a user

s name, tap the name and edit with the onscreen keyboard. To modify a password, tap the number to 

edit and set using the onscreen key pad. 

User Settings:

 

Allows configuration of settings on the device. Key Beep will adjust the tone played during button presses. There are 4 
options including off. Touchpad Timeout will set how long the screen stays unlocked during cover operation when no 
button is pressed. Screen brightness can be adjusted using the displayed slider. The Set time button will bring up a 
screen to adjust the time, date, and time zone. If connected to a WiFi network, internet time can be used to automatically 
set the time.  

WiFi Setup:

 

From this screen you can connect the device to the internet through a home WiFi network, or lock/unlock the local 
wireless network. 

To download the 
latest firmware either 
scan the QR code or 
enter the URL below 
into your browser. 
 
https://rb.gy/suvbuu  

Содержание Latham

Страница 1: ...in an all weather junction box as high as possible in the cover box Install this device in accordance with national and local electrical codes NEC 680 26 Electrical wiring and service work should only...

Страница 2: ...f Latham s 3 wire motor offerings either directly or through a control board It is compatible with the 121 Motor Controls and the 3 Wire Limit control board assemblies It also has built in Latham mesh...

Страница 3: ...ral White 6 Motor Direction 1 Red 3 4 5 6 2 1 Low voltage wiring Color 5v DC Red Gnd DC Black Control board Rx White Control board Tx Green Wiring Description System Diagram and Configuration Options...

Страница 4: ...om left corner Set a Primary Controller 1 Select a controller to set as Primary If only one touch controller is used in the system it should be set as the Primary If multiple controllers are in the sy...

Страница 5: ...current devices assigned to this network and prevent other devices in the area from connecting If a network is not locked the system will automatically lock the network after 2 hours Assign Main Devi...

Страница 6: ...u then the Maintenance menu In the Maintenance Menu select the Reboot button to restart the device 8 After approximately 5 minutes the device will finish connecting to the WiFi network Once connected...