10
Menu
Sensor
Setting
Possible settings
Default setting
Settings
Sensors
Aux. flow
Mode
•
OFF
•
ON
OFF
Type
•
NO
•
NC
NO
pH container
Mode
•
OFF
•
ON
ON
Type
•
NO
•
NC
NO
Aux. flow :
auxiliary flow sensor placed on the injection hydraulics of the pH
corrector (optional, not provided).
pH container:
empty container sensor
Type:
this parameter does not appear if the corresponding mode is set to OFF.
ON:
sensor activated.
OFF:
sensor disabled.
NO:
switch normally open.
NC:
switch normally closed.
Sensor activated
Configuration
Specific display
Regulation of pH
Aux. flow
Sufficient flow
-
Maintained
Zero flow
Alarm
Flow
Stopped
Empty pH container
Empty container
Alarm
Empty pH container
Stopped
Container not empty
-
Maintained
2.7.4.
Settings reset
Menu
Important warning
Settings
Reset. Sett.
I
Resetting the settings cancels all the settings carried out (factory configuration).
2.8.
Data history
Menu
Sub-menu
Content
History
pH calibration
-
Date of the last pH probe calibration
History
Filtration
Filtration
Time D-1
Duration of filtration pump operation the previous day
Filtration
Average time W-1
Average daily operating time of the filtration pump the previous week
Filtration
Average time M-1
Average daily operating time of the filtration pump the preceding month
History
pH injection
pH injection
Time D-1
Duration of pH corrector pump operation the previous day
pH injection
Average time W-1
Average daily operating time of the pH corrector pump the previous week
pH injection
Average time M-1
Average daily operating time of the pH corrector pump the previous month
pH injection
Total
Cumulative duration of pH corrector pump operation since the first start-up of the
electronics unit