AUTOSALT®/POOLSQUAD®/POOLSQUAD® AMPERO/PRO - PAPI004082
–
FR/EN/ES/DE - Rev.03.16
23
SECURITY
PH REGULATION
OK
Chlorination ON
pH Regulation ON
Detection of a defect of chlorine production.
Make a chlorination test (see § 7) to determine the origin of the
defect.
Acid
mode
Chlorination
ON
pH
Regulation
STOP
You have to measure pH level with usual analysis kit. If this one
corresponds to POOLSQUAD display, you have to wait until pH goes
back up. If it doesn’t match, you have to check proper functioning of
pH probe with a new manual calibration.
Basic
mode
Chlorination
ON
pH
Regulation
STOP
1/ Check that corrective tin solution is not empty
2/ Check that the probe injects correctly by making a manual
injection particular menu.
3/ Check the smooth running of the pH probe in doing again a manual
calibration.
4/ Check the injection and pursuit valves.
Acid
mode
Chlorination
ON
pH
Regulation
STOP
1/ Check that corrective tin solution is not empty
2/ Check that the probe injects correctly by making a manual
injection particular menu.
3/ Check the smooth running of the pH probe in doing again a manual
calibration.
4/ Check the injection and pursuit valves.
Basic
mode
Chlorination
ON
pH
Regulation
STOP
You have to measure pH level with usual analysis kit. If this one
corresponds to POOLSQUAD display, you have to wait until pH goes
back up. If it doesn’t match, you have to check proper functioning of
pH probe with a new manual calibration.
Chlorination ON
pH Regulation STOP
Regulation problems (the last pH corrective attempts are
unsuccessful). All models excepted Autosalt®
1/ Check that the corrective tin is not empty.
2/ Check that the probe injects correctly by making a manual
injection in the pH setting menu.
3/ Check the smooth running of the pH probe in doing again a manual
calibration (see § 6.2).
4/ Check the injection and pursuit valves.
Chlorination STOP
pH Regulation OFF
If flow sensor in option is installed.
Detection of a lack of flow in waterworks.
Make sure the presence of water in piping (check the opening of
valves) and filtering pump working.
Chlorination STOP
pH Regulation ON
Only for Poolsquad® Ampéro
Detection of a defect in the automatic probe regulation.
It could have many causes :
1/ Check the flow in the measure chamber.
2/ Check the presence of gel in the probe. If necessary, add gel (see §
6.5).
3/ Chlorine probe out of order: change in the chlorine probe.
4/ Chlorine probe bad connected or not linked: check that the probe
is correctly linked.
Chlorination ON
pH Regulation ON
Only for Poolsquad® Ampéro model
Alarm triggered
The last change of gel goes back of 60 days (by default) : you have to
change the gel.
CAREFUL
Cell power
OK
CAREFUL
Low pH
OK
CAREFUL
TOO HIGH PH
OK
SECURITY
NO FLOW
OK
SECURITY
DEFECT OF CHLORINE
OK
GEL CL probe
OK