SECURITY
LACK OF WATER
OK
✓
Switch off the device and unplug the probe of the device. Close gates of the by-pass and bring out
the probe of the chamber of measure.
✓
Unscrew at half tank of the probe.
✓
Open the bottle of gel and expel the air. Pour the gel without making of air
bubbles.
✓
Re-screw the tank and tight hardly up to the abutment. The surplus of gel
is evacuated by the elastic ring.
✓
Proceed to a new calibration of chlorine measure (see §4.7)
It is recommended to use only spart parts and/or replacement units from POOL TECHNOLOGIE.
7/ MAINTENANCE OPERATIONS
SELFDIAGNOSIS PROGRAM
In case of defect of production or in case of doubt about the smooth running of the device, launch the auto
diagnosis program:
At the end of the test (around 1 minute), the device shows its result :
Code
Causes / Remedies
Pump timer
problem
The self-diagnosis detected a problem of power inside the controller box.
You have to contact a Professional so that he proceeds to the repair of the controller box.
Cell
problem
The self-diagnosis detected a defect coming from the cell.
1/ Check visually that the cell is not scaled (see
§
6.4
)
2/ Check that connexions
to the borders of the cell are not oxidized and well squeezed.
3/ In most of cases, this code shows that your cell is totally used and cannot produce chlorine anymore. You
have to contact a professional to proceed to the replacing of the chlorination cell.
Test OK
The self-diagnosis detected no problem coming from electronic box or from the cell.
If you have a problem of chlorine production, check that the rate of salt is upper than 2,5 kg/m
3
and that the
pH be closer of 7-7,2, an then contact a professional for an analysis.
SECURITIES OF THE DEVICE
Security
Function
Cause / Action
Chlorination OFF
pH Regulation OFF
Detection of a lack of water in waterworks.
Make sure of the presence of water in piping (check the opening of
valves).
Chlorination STOP
pH Regulation ON
Salt rate in the pool lower than 2,5 Kg/m
3
.
1/ Look at the present salt rate in the pool.
2/ Add salt as to obtain 5 kg/m
3
of salt.
3/ Make Salt probe calibration (see § 5.2).
CAREFUL
LACK OF WATER
OK
1
2
CHLORINATION SALT TEST
◄►
OK
CHLORINATION SALT
◄►
OK
CHLORINATION SALT TEST
◄►
OK
CHLORINATION SALT
◄►
OK