background image

TD4000A Hardware User Manual 

 

 

 

 

 

 
 

PONOVO POWER CO., LTD 

 

2F, 4Cell, Tower C, In.Do Mansion 
No.48A Zhichun Road, Haidian District 

 

Beijing, China (Post Code 100098) 

 

Office

 

TEL. +86 (10) 82755151-8887 

FAX +86 (10) 82755257 

 

E-Mail [email protected] 
Website www.relaytest.com 

 

 

 

 

 

 

 

TD4000A 

 

HARDWARE USER MANUAL 

 

 

VERSION:

 

TD4000A-AE-1.02 

DATE:

 

26/06/2012 

 

 

 

 

 

 

 

 

 

 

 

 

This manual is the publication of PONOVO POWER CO., LTD. Any form of copy needs 
to be consent by PONOVO POWER CO., LTD. 

 

This manual represents the technical status for the moment of publishing. The product 
information, description and specifications mentioned in the manual do not have any 
contact binding force and PONOVO POWER CO., LTD remains the right to make 
modifications to the technical specifications and configurations without prior notice. 
PONOVO does not take responsibility to the possible error/mistakes in this manual. 

 

 

Содержание TD4000A

Страница 1: ...his manual is the publication of PONOVO POWER CO LTD Any form of copy needs to be consent by PONOVO POWER CO LTD This manual represents the technical status for the moment of publishing The product information description and specifications mentioned in the manual do not have any contact binding force and PONOVO POWER CO LTD remains the right to make modifications to the technical specifications a...

Страница 2: ... A B power supplies are open circuit It continues working after over hot recovery The output of serial connection is suitable for loaded voltage above 4V and when the loaded voltage is below 4V serial connection is prohibited Over loaded alarm exists when connecting in parallel The tester is working when it is overloaded in single circuit or parallel connection but the output time is less than 20 ...

Страница 3: ...sion and weight 8 3 7 Environmental conditions 8 4 Operation Instructions 9 4 1 Select test functions 9 4 2 Choose variables 10 4 3 Set test parameter 10 4 4 Output control 10 4 5 Check and save test report 11 4 5 1 Check test report 11 4 5 2 Save test report 11 4 6System settings 12 5 Test functionality instructions 13 5 1 Manual test 14 5 2 PC Control 16 6 Accessories 17 7 Installation of test f...

Страница 4: ...ing in Special high voltage DC converter station DC current transformer control and protection 2 Panel Description 1 Power output it supports max 3x3 bus bar connected in parallel 2 Binary Binary output 1 relay connection point Binary input 2 no polarity differences It can be used to receive protection connection point and milliseconds test and single or dual channel are optional 3 Indication lamp...

Страница 5: ...put is cut Over load indicator The lamp flashes when the current and voltage are over loaded and manually stops the output 4 Menu setting and adjustment output control unit 5 USB for reading the report and connecting with PC 6 Input Power Three phase four wire input 7 Power Switch 8 Three phase power indication lamp the lamp flashes when current input is completed 5 ...

Страница 6: ... Output range 0 4000A Accuracy 0 1 Port voltage 5 0V Max output time 1000A 2000A 4000A at full current Continuous 240 s 60 s load 10 99 raising 0A 4000A time 20 ms 90 10 falling 4000A 0A time 10ms DC current table Model TD4000A DC test range 0A 100A 100A 500A 500A 4000A Accuracy 1 0 5 0 2 6 ...

Страница 7: ...le with 30V 250V potential It is auto identification and time accurate of 1ms 0 001 1s 0 1 1 999 999s Figure 1 2 3 3 Binary output One pair contact rating 250V DC 0 5A 250V AC 8A 3 4 LED 4 8 inch High brightness LCD and visible in glare 3 5 Power input Rated input Three phase four cable 380V 50Hz input voltage range 10 20 50Hz 7 ...

Страница 8: ...rdware User Manual 3 6 Dimension and weight Dimension 660mm x 450mm x 880mm L W H Weight 110kg 3 7 Environmental conditions Temperature 0 40 Relative humidity 90 non condensing Atmospheric pressure 86kPa 106kPa 8 ...

Страница 9: ...re are four buttons F1 F2 F3 and menu in the test unit area Choose main menu button at any interface to enter the main menu Entering the main menu rotate ENTER button to select the test function and push the ENTER go to specified function Push F1 in sub menu to go back the main menu 9 ...

Страница 10: ...riable parameter by pushing ENTER button and rotating it clockwise and counterclockwise Select parameter step by pushing coarse fine tuning The step changes among 0 1 1 and 10 Relative parameters can be set by selecting variable settings before testing And the parameters cannot be changed during testing 4 4 Output control Functions of output and stop output can be set by pushing run and stop butto...

Страница 11: ... entering the report check interface Ten reports can be displayed in each page and 30 reports can be stored 1 3 means that there are three pages and the present is the first page 4 5 2 Save test report After testing the present project can be saved through screen tips and test report is saved in the form of date and time 11 ...

Страница 12: ...TD4000A Hardware User Manual 4 6 System settings Screen backlight buzzer and time can be set by choosing main menu system settings 12 ...

Страница 13: ...nual 5 Test functionality instructions In this unit maximum 4000A can be output manually The current amplitude and output time can be controlled the action time can be measured here The following is the main menu of the set 13 ...

Страница 14: ...Manual 5 1 Manual test This unit can put out current of 4000A at maximum which can control current amplitude and output time manually and test opening time This is the operation interface Connect the cables as followings 14 ...

Страница 15: ...period of cooling time which is connected with the present current output time and maximum time is 120s After cooling it can go to next output The equipment needs 30s cooling time after power on and it counts from current output until that the binary receives signal flip recording actions time Notes The cooling time means the minimum cooling time for the equipment normal working It is advisable th...

Страница 16: ...TD4000A Hardware User Manual 5 2PC Control Main functions of PC Control test are transmitting test report to PC and test step grading and state sequence 16 ...

Страница 17: ... 6 Accessories 1 250 fixture 2 sets It is used for testing bus cable with diameter of 250mm seeing the installation below 2 50 fixture 10 sets It is used for testing bus cable with diameter of 50mm seeing the installation below 17 ...

Страница 18: ...ork with 50 fixture It is used for testing bus cable with diameter of 30mm seeing the installation below 4 4000A installation bus bar 12 pieces 10M 6 pieces 6M 6 pieces It is used for connecting equipments and fixture seeing the installation below 18 ...

Страница 19: ...TD4000A Hardware User Manual 5 2 wrenches 6 Power cord Yellow green red Blue Yellow green or black L1 L2 L3 no phase Zero line N Earth wire sequence 19 ...

Страница 20: ...TD4000A Hardware User Manual 7 High intensity air box 3 It is used to pack the accessories 20 ...

Страница 21: ...000A Hardware User Manual Bus dedicated connector Optional The position placed in the package There are two floors In the first floor there is 250 fixture In the second floor there are 50 and 30 fixture 21 ...

Страница 22: ...xture 1 Bus bar Diameter is 250mm First clean the bus where the fixtures are installed and connect 250 fixture and bus cables showing in the picture Fasten the connection with screw nut showing below Connect the other end of bus cable with the equipment 22 ...

Страница 23: ...nd the tested bus bar showing in the picture Fasten the connection with screw nut If there are several bus cables 4 bus cables with diameter of 50mm can be connected to the bus cables front back left and right respectively and the loaded current is approximately 4000A showing below Connect the other end of bus cable with the equipment 23 ...

Страница 24: ...50mm and the tested bus bar Installed as the following Fasten the connection with screw nut If there are several bus cables 4 bus cables with diameter of 50mm can be connected to the bus cables front back left and right respectively and the loaded current is approximately 4000A showing below Connect the other end of bus cable with the equipment 24 ...

Отзывы: