t51
】
Heating Temperature Setpoint
(turn off point when heating to this
temp. Could be taken as the basic lower end to stay at in most cases);
【
Hd
】
Heating Differential
(set lower range trigger, how far from the TS1
setpoint temp can it drift before turning on heating);
【
t52
】
Cooling Temperature Setpoint
(turn off point when cooling to this
temp. Could be taken as the basic upper end to stay at in most cases);
【
Cd
】
Cooling Differential
(set upper range trigger, how far from the TS2
setpoint temp can it drift before turning on cooling);
【
Pt
】
Compressor Protection Time
(how long it will keep the
refrigerating compressor off between cycles);
【
Hr
】
High Ringing Alarm Limit
(set the temperature at which it will
start beeping to notify you that the temperature has gone too high);
【
Lr
】
Low Ringing Alarm Limit
(set the temperature at which it will start
beeping to notify you that the temperature has gone too low);
【
CR
】
Temperature Calibration
(to calibrate the temperature if it is
measuring incorrectly).