PN160 is an easy-to-use, safe and reliable dual relay output temperature controller. 

The multifunctional thermostat can be used in many areas in our daily life. It is perfect 

to be used as over temperature protection or automatic temperature control system for 

various tasks. Such as Sous-vide, Home-brew & Fermentation, Kegerator, Aquarium 

heat control, Breeding & Incubation, Germination & Seedling Heat Mat etc. 

 

Warning

 

To avoid electric shock or personal injury, read the “Safety Information” 

carefully before using the Thermostat. 

 

 

1.

 

DO NOT 

use the device on anything that could possibly have a 

rating 

and 

start-up amp

 greater than required (see 

Technical Specifications 

part).   

Note: 

Induction motors such as 

air conditioners

refrigerators

space heater

freezers

 and 

pumps

 may have a start-up amp of 2 to 8 times the continuous rating. 

2. 

DO NOT

 dismantle the device without authorization to avoid unexpected 

accident. 

3. 

DO NOT

 operate the controller around explosive gas, vapor or dust. 

4. 

DO NOT

 allow children to operate this device, keep children stay away 

from the controller. 

 

 

Содержание PN160

Страница 1: ...User Manual Model No PN160 Thank you for purchasing the Temperature Controller by Poniie Please read this manual carefully before using this product ...

Страница 2: ...shock or personal injury read the Safety Information carefully before using the Thermostat 1 DO NOT use the device on anything that could possibly have a rating and start up amp greater than required see Technical Specifications part Note Induction motors such as air conditioners refrigerators space heater freezers and pumps may have a start up amp of 2 to 8 times the continuous rating 2 DO NOT di...

Страница 3: ... use the output relays within their rated load Dual Relay Output Heating and Cooling Separate Heating and Cooling Setpoint Pre wired plug and play design Large backlight LCD display Waterproof NTC sensor Temperature calibration function Compressor delay protection time setting High and low temperature alarm setting Sensor fault alarm function 1 Functional Buttons SET 2 Indicator Light Status ON Re...

Страница 4: ...1 Hd Heating Differential HD t52 Cooling Temperature Setpoint TS2 Cd Cooling Differential CD Pt Compressor Protection Time PT Hr High Ringing Alarm Hr Lr Low Ringing Alarm Lr CR Temperature Calibration CA Sensor fault alarm Temperature Control Range TS1 HD TS2 CD Setpoint TS1 Range 19 9 TS2 Setpoint TS2 Range TS1 199 9 High Alarm Hr Limit TS2 199 9 Low Alarm Lr Limit 19 9 TS1 Calibration CA Range ...

Страница 5: ... we still recommend using the thermostat under above listed output load for durability and safe use Enter Setup Mode Press and hold SET key over 3 seconds to enter or quit parameters setup mode menu code will be displayed in flashing status Short press or the first time to show the default last time setting value Press SET key to cycle through all the setting menu Note 1 Press and hold or can adju...

Страница 6: ...in most cases Cd Cooling Differential set upper range trigger how far from the TS2 setpoint temp can it drift before turning on cooling Pt Compressor Protection Time how long it will keep the refrigerating compressor off between cycles Hr High Ringing Alarm Limit set the temperature at which it will start beeping to notify you that the temperature has gone too high Lr Low Ringing Alarm Limit set t...

Страница 7: ...S2 larger 1 1 TS 1 TS2 Limit Adjust Reminder Set TS1 smaller 1 1 Temperature Control Range Setting TS1 HD TS2 CD For example set TS1 77 F HD 2 F TS2 88 F and CD 3 F then when measured temperature is higher or equal to 91 F TS2 CD system enters refrigeration status when temperature decline to 88 F TS2 stop refrigeration when measured temperature is lower or equal to 75 F TS1 HD system enters heatin...

Страница 8: ... refrigerating compressor off between cycles to protect your compressor That means compressor won t start refrigeration immediately but waiting for a delay time if it falls into the PT time frame Delay time will be calculated right after the refrigeration stops 1 3 Temperature Calibration CA When there is deviation between measured and actual temperature use calibration function to align the tempe...

Отзывы: