background image

WAT E R G A R D E N I N G   T O   T H E   M A X

V I S I T

 

P O N D M A X . C O M

OUTDOOR 

AERATION PUMPS

DESIGN HIGHLIGHTS

BENEFITS INCLUDE

•  Weatherproof casing design for outdoor use. 

•  Quiet operation - Outer industrial plastic casing and 

air baffle, plus extra buffer chamber on outlet for 
exceptional low noise rating.

•  Dual Rubber mounting system for vibration absorption.

•  Robust design - Internal aluminum pump casing for 

excellent heat dissipation, which assists with durability 
and extends pump life.

•  Strong air pressure for deeper aeration and 

more air dispertion. 

•  No oil lubrication needed.

•  Easy maintenance - Replaceable internal rubber 

diaphragms. 

•  Continuous rated - Designed to operate 24/7.

The PondMAX Aeration Kits have been manufactured with advanced technology to provide you with the best quality 
aeration for your pond or water feature. Visit our website to view our range of pond filtration, outdoor/underwater 
lighting, water treatments and general accessories. PondMAX Aeration Kits are suitable for many different applications 
including aquariums and fish pond/water garden applications. Aeration is a very effective method of enhancing pond fish 
habitats, improving water quality, reducing algae, and removing phosphorus. Aeration can also break down unwanted 
bacteria, help with mosquito problems, and remove foul odours from a pond - all by circulating the water and adding 
dissolved oxygen.

•  Any damage to the equipment or unmerited operation 

can potentially bring dangers to the surrounding 
precincts. If there is any damage of the equipment, it 
must not to be used. The equipment should be placed 
out of reach of children.

•  For your own safety, completely disconnect all electrical 

appliances before any maintenance of equipment is 
attempted on/in the tank or body of water. Always 
unplug the air pump from the power supply when not 
in use. Never pull the cable to disconnect the plug 
from the power supply - Grasp the plug and pull to 
disconnect. Care should be taken to ensure the power 
cable is situated to avoid a tripping hazard.

•  Cutting the cable may void your warranty. 

•  If required, have a qualified electrician install a 

weatherproof power supply point in reach or the water-
feature (within the cable length of the appliance). For 
applications within the US or Canada- make sure to plug 
the pump into an electrical outlet with a (GCFI) Ground 
Fault Circuit Interrupter. For Australian applications-
always use a properly grounded power supply that is 
connected to an RCD, with a rated residual operating 
current. Do not exceed 30mA. [AS/NZS 3350.2.41:1997]

•  To prevent electric shocks, do not attach the plug to the 

power supply socket with wet hands. On installation, 
the drip loop method should be used to prevent water 

from traveling down the cable and onto the plug or into 
power supply. If the plug does get wet, do not unplug 
the cable. Immediately disconnect the circuit breaker 
that supplies power to the power supply point. Unplug 
and examine the plug and power supply point for the 
presence of water. If the power point has become wet, 
you should consult an electrician before using the 
power point again. 

•  Do not submerse air pump directly in water. The 

distance from air pump to the water’s edge should be 
at least 6Ft/1.8m. Use of the provided check valves is 
highly recommended, to ensure no moisture enters 
pump via airline. 

•  Do not operate the appliance if any components of the 

system, such as the power cable, have been damaged. 
Check appliance and components of the kit for defects 
regularly. 

•  Do not install or store the appliance where it will be 

exposed to extreme hot or cold temperatures. Do not 
use in ambient temperatures above 95°F/35°C

•  Do not attempt to repair the electrical appliance 

yourself. Return to an authorized dealer or place of 
purchase if a fault occurs. Regular maintenance is not 
considered a repair (e.g. replacing the diaphragms and 
air filter is required by user).

IMPORTANT SAFEGUARDS

Please read the operating instructions and familiarize yourself with the equipment before placing it in 
service. Correct and safe use of the system requires strict compliance with these safety instructions. 
For safety reasons persons less than 16 years of age or persons that are not familiar with these 
instructions, should not use this equipment.

PMAX Aeration Pumps PA10_PA20 Instructions.indd   3

26/6/17   1:32 pm

Содержание PA Series

Страница 1: ...VERSION JUN 2017 MODEL PA10 PA20 PA SERIES OUTDOOR AERATION KIT INSTRUCTION MANUAL PMAX Aeration Pumps PA10_PA20 Instructions indd 1 26 6 17 1 32 pm ...

Страница 2: ...TH 6 5 FT 2 M 6 5 FT 2 M AIR TUBING SIZE ID X LENGTH 3 16 X 30FT 4MM X 10M 3 16 X 30FT 4MM X 10M DESCRIPTION OF ACCESSORIES 1 x Rubber Elbow 2x Hose Clamp for Rubber Elbow 1 x Metal Air Manifold 2 Way 2 x Sphere Air Stone 2 x Rolls Air Line 1 x Extra Diaphragm 2 x Check Valves 1 x Rubber Elbow 2x Hose Clamp for Rubber Elbow 1 x Metal Air Manifold 4 Way 4 x Sphere Air Stone 4 x Rolls Air Line 1 x E...

Страница 3: ...quired have a qualified electrician install a weatherproof power supply point in reach or the water feature within the cable length of the appliance For applications within the US or Canada make sure to plug the pump into an electrical outlet with a GCFI Ground Fault Circuit Interrupter For Australian applications always use a properly grounded power supply that is connected to an RCD with a rated...

Страница 4: ...embly by locating the rubber manifold connector short piece of hose in the box and by attaching the provided hose clamps one on each end of the connector Then locate the metal manifold piece and press open end firmly into one end of the rubber connector as far as possible The remaining open end of rubber connector then needs to be put onto the outlet port of the air pump as far as possible Now Squ...

Страница 5: ... pump motor from the plastic housing 1 Locate the 4 Phillips screws on the top portion of plastic casing and untighten 2 Once the screws have been removed remove the top section along with the rubber gasket that seals the plastic casing 3 Now undo the next set of 4 Philips screws around the metal cover 1 that holds the motor Lift the metal motor housing 2 off the base and gently unsecure the cable...

Страница 6: ... rubber membranes and membrane frames back onto the magnet assembly Next reinstall the support disk tapered side against rubber membrane on both sides of magnet Before tightening the Phillips screw in the center on each rubber membrane make sure that the position of both frames lines up with indentation on back of frame that slightly mocks contour of magnet This indentation is designed to prevent ...

Страница 7: ...REPLACEMENT DIAPHRAGM ASSEMBLY 31PA110 31PA120 11PA333 11PA344 REPLACEMENT AIR FILTER SPONGE 31PA210 31PA220 11PA348 11PA350 REPLACEMENT ELBOW CLAMP AND METAL MANIFOLD 31PA310 31PA320 11PA349 11PA351 REPLACEMENT AIR LINE CHECK VALVE 2 PACK 31PA410 PONDMAX AIR STONE 2 SPHERE 28PA094 03PA307 PMAX Aeration Pumps PA10_PA20 Instructions indd 7 26 6 17 1 32 pm ...

Страница 8: ...r these instructions and check the air filter pad for discoloration caused by dust or dirt Using a household style vacuum cleaner suck debris out of pad until visibly clean And reinstall Bad Diaphragms Disassemble pump per these instructions and check the diaphragms for excessive wear and tear or possible tearing If diaphragm is damaged go ahead and replace before operating the unit again PUMP WOR...

Страница 9: ...ssary to effectuate repairs under this warranty This warranty is in lieu of all other express warranties which now or hereafter might otherwise arise with respect to this product Any and all limited warranties including the warranties of merchantability and fitness for particular purpose shall have no greater duration than the duration period of the express written warranty applicable to this prod...

Страница 10: ...oll Free 888 868 1185 sales pondmax com www pondmax com AUSTRALIA HEAD OFFICE 37 Edison Circuit Forrestdale WA 6112 HOTLINE 1300 278 283 sales aquatecequipment com www aquatecequipment com PMAX Aeration Pumps PA10_PA20 Instructions indd 10 26 6 17 1 32 pm ...

Отзывы: