WAT E R G A R D E N I N G T O T H E M A X
V I S I T
P O N D M A X . C O M
TROUBLESHOOTING
Please consult your retailer for quality original PondMAX replacement parts.
Visit www.pondmax.com for your nearest dealer.
PROBLEM
REASON
SOLUTION
PUMP NOT WORKING
No Power
Check that the plug on power cable is
connected to power and confirm that
power point is working.
Bad Motor
Replace the air pump (if applicable).
Damaged Cable
Inspect the entire length of the air pump
cable and look for cuts or damage
resulting in exposed copper wire. Replace
cable or complete unit.
PUMP WORKING
INTERMITTINGLY
Damaged Cable / Short Circuit
Inspect the entire length of the air pump
cable and look for cuts or damage
resulting in exposed copper wire. Replace
cable or complete unit.
Clogged Airline / Defective Check Valve
Inspect the entire length of the
airline tubing for blockage and check
functionality of check valves. Replace
airline or check valves if unrepairable.
Defective Pump
Inspect the inside of the air pump and
make sure that it is free of any signs of
damage or moisture. Replace air pump if
problem continues.
Air Filter Pad Clogged
Disassemble top of pump per these
instructions and check the air filter pad
for discoloration, caused by dust or dirt.
Using a household style vacuum cleaner,
suck debris out of pad until visibly clean.
And reinstall.
Bad Diaphragms
Disassemble pump per these instructions
and check the diaphragms for excessive
wear and tear or possible tearing. If
diaphragm is damaged, go ahead and
replace before operating the unit again.
PUMP WORKING WITH
MINIMAL AIR FLOW OR
MAKING LOUD NOISE
Bad Diaphragms / Membranes
Disassemble pump per these instructions
and check the diaphragms and rubber
membranes for excessive wear or possible
tearing. If diaphragms or membranes are
damaged, go ahead and replace before
operating the unit again.
Air Filter Pad Clogged
Disassemble top of pump per these
instructions and check the air filter pad
for discoloration, caused by dust or dirt.
Using a household style vacuum cleaner,
suck debris out of pad until visibly clean.
And reinstall.
Clogged Airline/Defective Check Valve
Inspect the entire length of the
airline tubing for blockage and check
functionality of check valves. Replace
airline or check valves if unrepairable.
PMAX Aeration Pumps PA10_PA20 Instructions.indd 8
26/6/17 1:32 pm