background image

WAT E R G A R D E N I N G   T O   T H E   M A X

A Q U AT E C E Q U I P M E N T. C O M

SUBMERSIBLE 

WATER PUMPS

PART 

NO.

DESCRIPTION

EV1900 / 

EV1910-DC

EV2900 / 

EV2910-DC

EV3900 / 

EV3910-DC

EV4900 / 

EV4910-DC EV-7200

EV-9200

EV-11200

EV-13600

1

Sponge Filter cage. 

12EV002

2

Internal Sponge Pre-filter Insert

12EV003

3

Flow Adjuster Knob - [EV1900 - 

EV4900]

12EV004

4

Front filter Screen - With hole for flow 

adjuster - [EV1900 - EV4900]

12EV005

Not 

Shown

Blanking Cap for Hole in Front Filter 

Screen (optional)

12EV006

5

1" Threaded Bush - for optional Pre-

filter Bio-sponge.

12EV009

6

Threaded Hosetail for Inlet - 1" BSP to 

25mm Tube

12EV001

7

Impellor Cover Housing

12EV010

12EV011

12EV012

12EV013

12EV014

12EV015

12EV016

12EV017

8

Impellor Assembly

12EV025

12EV026

12EV027

12EV028

12EV029

12EV030

12EV031

12EV032

9

Impellor cover O'ring

12EV033

12EV034

12EV035

10

Sliding Base with Rubber Feet

11

Pump Motor Body

12

Reducing Bush - 1" to 1 1/2" BSP 

Threaded.

12EV018

13

O'ring for Ball Joint and Hosetails, Red 

12EV021 (x2)

14

Uni-directional Ball Joint for 

Submerged Use.

12EV019

15

Threaded Bush - 1 1/2" BSP

12EV023

16

Hosetail with  - 1 1/2" BSP Thread to 

50/40mm Tubing

12EV024

17

Hosetail with Locking Collar - 1 1/2" 

BSP Thread to 40/32/25mm Tubing

12EV022

18

Front filter screen - (no flow adjuster) 

EV7200 & EV9200

12EV007

19

Front filter screen - (no flow adjuster) 

EV11200 & EV13600

12EV008

2, 9,

12, 13, 

14, 17

Complete Kit EV1900-EV4910-DC 

- O'rings, Inlet & Outlet, Threaded 

Bushes and Uni-directional Balljoint.

13EV036

9, 13,

14, 15,

16, 18

Complete Kit For EV7200-EV9200 

- O'rings, Inlet & Outlet, Threaded 

Bushes and Uni-directional Balljoint.

13EV037

9, 13,

14, 15,

16, 18

Complete Kit For EV11200-EV13600 

- O'rings, Inlet & Outlet, Threaded 

Bushes and Uni-directional Balljoint.

13EV038

PMAX EVOII 7200_9200_11200_13600 Pump Instructions.indd   9

7/11/17   7:53 am

Содержание Evo II series

Страница 1: ...E WATER PUMP INSTRUCTION MANUAL HOTLINE 1300 AQUATEC VERSION JUNE 2016 MODEL 02EV200 EV7200 02EV225 EV9200 02EV250 EV11200 02EV275 EV13600 PMAX EVOII 7200_9200_11200_13600 Pump Instructions indd 1 7 11 17 7 53 am ...

Страница 2: ...READED BALL JOINT OUTLET 1 1 2 MALE BSP Yes Yes Yes Yes CABLE LENGTH M 10 10 10 10 RECOMMENDED TUBING SIZE MM ID 40 40 50 75 OTHER MODELS AVAILABLE IN THE EVOII RANGE EV1900 EV2900 EV3900 EV4900 EV1910 DC EV2910 DC EV3910 DC EV4910 DC MAXIMUM WATER FLOW L H 1800 3000 4000 4900 1800 3000 4000 4900 MAXIMUM HEAD M 2 4 3 4 3 8 5 0 2 4 3 4 3 7 4 6 VOLTS V 240 240 240 240 12V DC 12V DC 12V DC 12V DC SUI...

Страница 3: ...nnot suck from a water level that is below the inlet level when used in line Your pump has a single moving part an impellor set enabling easy cleaning and maintenance The models EV1900 EV13600 Pumps have intelligent circuitry that analyses the speed and torque of the motor It will increase and decrease the energy usage to maximise efficiency The soft start nature of the system helps to avoid sudde...

Страница 4: ... cut the cable as this will result in voiding your warranty Care should be taken to arrange the power cable so that it cannot be accidentally tripped over or pulled Do not attempt to repair the electrical appliance yourself Return to an authorized service centre or place of purchase if a fault occurs regular maintenance is not considered repair and is required by user IMPORTANT SAFEGUARDS Please r...

Страница 5: ...his is because the diagonal side sections of the ball joint may seep water when in use The fittings pack include the necessary O Ring washers Select the one that will fit the female connection of the ball joint Place it firmly in the locking nut Now screw the locking nut of the ball joint onto the outlet of the pump Fasten firmly but do not over tighten Then connect the 1 1 2 threaded bush to the ...

Страница 6: ...oled if pump becomes restricted or blocked it will overheat and could cause permanent damage The motor unit of the pump is encapsulated with epoxy resin and does not need lubrication Regular inspections cleaning and maintenance of impellor is necessary to ensure longer life In the centre of the impellor you may notice a small whole opening that protrudes through the ceramic shaft from front to bac...

Страница 7: ...r into the motor body To place the Impellor O Ring around the black disc successfully firmly hold the disc with one hand and using the other hand stretch the O Ring over the disc positioning it carefully into the groove Pay attention not to allow the O Ring to roll forward in between the black disc and the motor body With the impellor in the correct position carefully place the impellor cover back...

Страница 8: ... 50 40mm Tubing Hosetail with Locking Collar 1 1 2 BSP Thread to 40 32 25mm Tubing Front filter screen no flow adjuster EV7200 EV9200 only Front filter screen no flow adjuster EV11200 EV13600 only 1 2 3 4 not shown 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1 2 3 4 5 7 8 9 10 11 6 12 13 14 15 16 17 13 18 19 NOTE Parts and features differ from model to model All images used are for illustrative purpos...

Страница 9: ...3 12EV034 12EV035 10 Sliding Base with Rubber Feet 11 Pump Motor Body 12 Reducing Bush 1 to 1 1 2 BSP Threaded 12EV018 13 O ring for Ball Joint and Hosetails Red 12EV021 x2 14 Uni directional Ball Joint for Submerged Use 12EV019 15 Threaded Bush 1 1 2 BSP 12EV023 16 Hosetail with 1 1 2 BSP Thread to 50 40mm Tubing 12EV024 17 Hosetail with Locking Collar 1 1 2 BSP Thread to 40 32 25mm Tubing 12EV02...

Страница 10: ...erwater then plug in Refill if necessary Blocked Impellor chamber or ceramic shaft is broken Clean the Impellor Check for wear Replace if necessary WATER PUMP IS NOISY Blockage in pump Clear the blockage Impellor Shaft worn out Replace Impellor Shaft Impellor broken Replace Impellor Water valve closed on the inlet or outlet Open the valve and allow Unit inlet is blocked or the water pump outlet is...

Страница 11: ...o be valid an original proof of purchase must be provided Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the f...

Страница 12: ...HOTLINE 1300 AQUATEC PMAX EVOII 7200_9200_11200_13600 Pump Instructions indd 12 7 11 17 7 53 am ...