background image

WAT E R G A R D E N I N G   T O   T H E   M A X

A Q U AT E C E Q U I P M E N T. C O M

SUBMERSIBLE 

WATER PUMPS

INSTALLATION

For your convenience, a filter-less cage has been used on this model.  It has a flat section on the front nose.  This is to 

facilitate a vertical mount is necessary. 

•  A basic plastic fountain kit is not recommended for 

pumps that have flow over 6000L/hour.  It’s better 
to use commercial fountain nozzles for higher flow.  
If using fountain nozzles, it is recommended that a 
sponge pre-filter be used. See your local dealer for 
examples.

•  If used to supply water to a waterfeature, cascade, 

waterfall, etc; where a pipe is needed to be used, 
use the hose tails supplied in the package.  For best 
results, use the bigger tubing size recommended in 
the table previously.  Depending on the pump size, 
select the hose tail required for your tubing size and 
evaluate which step on the hose tail will be used.  If 
you are using 50mm hose and you are connecting it 
to the 40mm/50mm hose tail supplied, remember to 
saw off the smaller size connection (I.E.: 40mm step).  
Otherwise it will create a unnecessary restriction in the 
system. 

•  Using a suitable thread seal tape (or other sealing 

compound) apply a liberal amount on the male thread 
of the hose tail.  

•  A omni-directional ball-joint is provided for your 

convenience when used under water. This is because 
the diagonal side sections of the ball-joint may seep 
water when in use.  The fittings pack include the 
necessary O’Ring washers.  Select the one that will fit 
the female connection of the ball-joint.  Place it firmly 
in the locking nut.  Now screw the locking nut of the 
ball-joint onto the outlet of the pump.  Fasten firmly 
but do not over tighten. 

•  Then connect the 1 1/2” threaded bush to the outlet of 

the ball joint. Then connect the hose tail to the bush 
and screw in firmly.  To seal adequately, use thread seal 
tape on this male thread.  

•  Now connect the tubing to the hose tail.  Remember to 

use S/Steel hose clamps to fasten the hose on to the 
hosetail.  This is to ensure that the hose does not blow 
off at a later time or there become a leak at this point 
in the plumbing system.  

•  When used in a pond environment place the pump 

in desired location; ensure the pump is on a stable 
surface that is free of sludge, sand and other debris. 
Position the device in the pond horizontally, on a solid 
base, in such a way that it is fully covered with water 
and ensure that the pump is located, at a depth, in 
the water, which will not allow it to suck air from the 
surface. This is known as cavitation. Cavitation is a 
cause of premature impellor wear.

•  Direct the hose to your desired location.  

•  To power up, push the plug into the power supply 

outlet and switch on. Use the power supply switch for 
turning the unit on and off.

PMAX EVOII 7200_9200_11200_13600 Pump Instructions.indd   5

7/11/17   7:53 am

Содержание Evo II series

Страница 1: ...E WATER PUMP INSTRUCTION MANUAL HOTLINE 1300 AQUATEC VERSION JUNE 2016 MODEL 02EV200 EV7200 02EV225 EV9200 02EV250 EV11200 02EV275 EV13600 PMAX EVOII 7200_9200_11200_13600 Pump Instructions indd 1 7 11 17 7 53 am ...

Страница 2: ...READED BALL JOINT OUTLET 1 1 2 MALE BSP Yes Yes Yes Yes CABLE LENGTH M 10 10 10 10 RECOMMENDED TUBING SIZE MM ID 40 40 50 75 OTHER MODELS AVAILABLE IN THE EVOII RANGE EV1900 EV2900 EV3900 EV4900 EV1910 DC EV2910 DC EV3910 DC EV4910 DC MAXIMUM WATER FLOW L H 1800 3000 4000 4900 1800 3000 4000 4900 MAXIMUM HEAD M 2 4 3 4 3 8 5 0 2 4 3 4 3 7 4 6 VOLTS V 240 240 240 240 12V DC 12V DC 12V DC 12V DC SUI...

Страница 3: ...nnot suck from a water level that is below the inlet level when used in line Your pump has a single moving part an impellor set enabling easy cleaning and maintenance The models EV1900 EV13600 Pumps have intelligent circuitry that analyses the speed and torque of the motor It will increase and decrease the energy usage to maximise efficiency The soft start nature of the system helps to avoid sudde...

Страница 4: ... cut the cable as this will result in voiding your warranty Care should be taken to arrange the power cable so that it cannot be accidentally tripped over or pulled Do not attempt to repair the electrical appliance yourself Return to an authorized service centre or place of purchase if a fault occurs regular maintenance is not considered repair and is required by user IMPORTANT SAFEGUARDS Please r...

Страница 5: ...his is because the diagonal side sections of the ball joint may seep water when in use The fittings pack include the necessary O Ring washers Select the one that will fit the female connection of the ball joint Place it firmly in the locking nut Now screw the locking nut of the ball joint onto the outlet of the pump Fasten firmly but do not over tighten Then connect the 1 1 2 threaded bush to the ...

Страница 6: ...oled if pump becomes restricted or blocked it will overheat and could cause permanent damage The motor unit of the pump is encapsulated with epoxy resin and does not need lubrication Regular inspections cleaning and maintenance of impellor is necessary to ensure longer life In the centre of the impellor you may notice a small whole opening that protrudes through the ceramic shaft from front to bac...

Страница 7: ...r into the motor body To place the Impellor O Ring around the black disc successfully firmly hold the disc with one hand and using the other hand stretch the O Ring over the disc positioning it carefully into the groove Pay attention not to allow the O Ring to roll forward in between the black disc and the motor body With the impellor in the correct position carefully place the impellor cover back...

Страница 8: ... 50 40mm Tubing Hosetail with Locking Collar 1 1 2 BSP Thread to 40 32 25mm Tubing Front filter screen no flow adjuster EV7200 EV9200 only Front filter screen no flow adjuster EV11200 EV13600 only 1 2 3 4 not shown 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1 2 3 4 5 7 8 9 10 11 6 12 13 14 15 16 17 13 18 19 NOTE Parts and features differ from model to model All images used are for illustrative purpos...

Страница 9: ...3 12EV034 12EV035 10 Sliding Base with Rubber Feet 11 Pump Motor Body 12 Reducing Bush 1 to 1 1 2 BSP Threaded 12EV018 13 O ring for Ball Joint and Hosetails Red 12EV021 x2 14 Uni directional Ball Joint for Submerged Use 12EV019 15 Threaded Bush 1 1 2 BSP 12EV023 16 Hosetail with 1 1 2 BSP Thread to 50 40mm Tubing 12EV024 17 Hosetail with Locking Collar 1 1 2 BSP Thread to 40 32 25mm Tubing 12EV02...

Страница 10: ...erwater then plug in Refill if necessary Blocked Impellor chamber or ceramic shaft is broken Clean the Impellor Check for wear Replace if necessary WATER PUMP IS NOISY Blockage in pump Clear the blockage Impellor Shaft worn out Replace Impellor Shaft Impellor broken Replace Impellor Water valve closed on the inlet or outlet Open the valve and allow Unit inlet is blocked or the water pump outlet is...

Страница 11: ...o be valid an original proof of purchase must be provided Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the f...

Страница 12: ...HOTLINE 1300 AQUATEC PMAX EVOII 7200_9200_11200_13600 Pump Instructions indd 12 7 11 17 7 53 am ...

Отзывы: