WINTERIZATION

CAUTION: During harsh winters, water left in the drum may freeze, expand and crack the 

drum.  If necessary, the filter can be drained and winterized at the end of the season.  If you 

live in an area that doesn’t experience freezing temperatures, you may never need to do this.

To empty the water from the filter drum, it is not necessary to open the filter.
1) Turn off the pump and disconnect the power source to the UV.
2) Turn the Valve to position #7 WINTER.
3) Remove the drain plug at the bottom of the filter to empty the filter from the bottom. 

Note that the drain plug adaptor has a ½” NPT female thread for attachment to ½” NPT male 

fittings. If you want to attach a hose to the bottom drain, you can purchase a ½” NPT fitting 

to connect to the bottom drain adaptor and to a hose. ½” NPT fitting are available at 

hardware stores or irrigation supply centers
4) If your set-up includes a UV Clarifier, rotate the lock ring counter clockwise to remove it. 

Pull the socket cap/light unit assembly straight up, being careful not to break the UV lamp. 

Disconnect lamp from socket by grasping the plastic base of the lamp and carefully pulling it 

straight apart from the socket cap. Remove the quartz sleeve from the filter cover by pulling 

straight upwards. Pack the quartz sleeve and UV lamp carefully and store it with the O-ring 

and socket cap/ ballast for winter. Cover the open UV port with the clear extra UV port cap 

that was placed in storage. DO NOT ALLOW WATER TO GET INTO UV QUARTZ SLEEVE AND 

FREEZE. IT WILL CRACK WHEN WATER FREEZES.

CLEARGUARD BACKWASH AIR KIT: 

For more thorough backwashing and 

agitation in the media filter chamber to break up the stubborn debris. It 

connects though the drain plug at the bottom of the pressure filter. 

UV Clarifier

 - Upgrade your filter by adding 

an ultraviolet clarifier to a non UV unit or 

add a second UV clarifier using the extra 

port for additional algae control. 

Replacement 

Filter Pads

 - 

Available to 

replace the 

filter pads 

that were 

supplied with the pressure filters. 

For 2700, 5000 & 8000 series 

Pressure filter use ITEM15640. 

For16000 Pressure filters use 

ITEM 15645. 

Biomatrix 1

1

/

4

” (32mm)Ball Media

 - Increase the biological filtration by 

adding more media. The Biomatrix Ball media is the only media recom-

mended for use with ClearGuard pressure filters. Available in bags of 300 

ITEM # 15650.

Caution: Do not use undersized media; it will get caught in valve and 

possibly damage the filter. 

OPTIONAL ACCESSORIES 

120V ONLY

Pond Filter 

Capacity

Maximum water

pump size

2700 GAL / 10000 L
5500 GAL / 20000 L
8000 GAL / 30000 L

3000 GPH / 11350 LPH
6000 GPH / 22700 LPH
8000 GPH / 30300 LPH

Clearguard Backwash Air Kit Item #

No airpump included Airpump included (120V) 

15675
15675
15675

15660
15660
15670

16000GAL / 60000 L 9000 GPH / 34000 LPH

15675

15670

Filter Item #

2700
5500
8000 

120V

230V

15

8

10

15

8

20

15611
15621

16000 

Watage

Voltage 

9W

18W
18W
18W

15

8

20

15

8

20

15621
15621

Содержание 05610

Страница 1: ...1 PRESSURIZED POND FILTER CARE AND OPERATING INSTRUCTIONS ZG400 revD 1 18 MODELS ITEM 120V 2700 05610 05615 5500 05620 05625 8000 05630 05635 16000 05640 05645 With UV No UV 230V 05617 05627 05637 ...

Страница 2: ...ding to allow the bacteria colonies to grow The time required varies depending on climate weather conditions fish load and feed rates Until the colonies grow large enough the pond owner must take care to monitor levels of ammonia and nitrates in the water and take appropriate measures to correct any dangerously high levels CAUTION Note that smaller filter media cannot be used with this filter It w...

Страница 3: ......

Страница 4: ...chamber of filter drum Place Foam Filter pad in upper end of filtration chamber CHECKTHAT DRAIN PLUG IS IN PLACE ANDTIGHTENED SECURELY FILTER SET UP Note position of alignment tab on filter drum and matching notch on filter cover Press cover straight down Do not twist or shift as it may unseat the gasket O ring 4 IMPORTANT CLEAN LUBRICATE ALIGN ALIGN COVER NOTCH ONLY LUBRICATEWITH SILICONE GREASE ...

Страница 5: ...ATING INSTRUCTIONS PRESS COVER COMPLETELY DOWN ATTACH RING CLAMP 3 Unions PVC Cement not included Carefully follow the instructions supplied with PVC cement MODEL 16000 MODEL 8000 5500 2700 USE SLIP ADAPTOR ON ALL PORTS O RINGS MUST BE SEATED IN GROOVE ON ALL THREE PORTS USE BARB FOR 3 FLEXIBLE TUBING IT MUST BE CEMENTED TO SLIP ADAPTOR USE COLLAR TO SECURE EITHER BARB FITTING OR SLIP ADAPTOR 3 RI...

Страница 6: ...TING INSTRUCTIONS 1 Put the valve to position 1 FILTER 2 Turn on pump and check all connections Check that pressure gauge pointer is in the Green zone Run filter with Foam Filter pad and Biomatrix Ball media at first The Biomatrix Ball media works best when the filter s bacteria colonies are established It takes a few weeks for the bacterial colonies to grow on the media and be effective for filtr...

Страница 7: ......

Страница 8: ...not fit the outlet have a proper outlet installed by a qualified electrician NOTEPOSITION OF O RINGS t I I 1 UV FIXTURE WITH BALLAST O RING UNDER TOP FLANGE OPEN UV PORT ON FILTER COVER NOTE YOUR FILTER AND UV ACCESSORIES MAY VARY FROM REFERENCE ILLUSTRATION A DANGER ULTRAVIOLET RADIATION Disconnect Power Before Replacing Lamp Connect only to a circuit that is protected by a ground fault circuit i...

Страница 9: ... for winter Cover the open UV port with the clear extra UV port cap that was placed in storage DO NOT ALLOW WATER TO GET INTO UV QUARTZ SLEEVE AND FREEZE IT WILL CRACK WHEN WATER FREEZES CLEARGUARD BACKWASH AIR KIT For more thorough backwashing and agitation in the media filter chamber to break up the stubborn debris It connects though the drain plug at the bottom of the pressure filter UV Clarifi...

Страница 10: ...If still slow make adjustments to set up Outlet is clogged Check for obstructions and clear outlet Filter drum is leaking at perimeter O Ring or Gasket is missing twisted dirty or was not lubricated Turn off pump Open filter and remove clean re seat and lubricate O Ring gasket Attach cover checking alignment of tab slot and thoroughly tighten clamp knob Water pressure is too high Pump is too large...

Страница 11: ...arge Bottom Grid 11 4 BioMatrix Ball Media UV models Only 18Watt Fixture Ballast Lamp Sleeve Clear Cap 9Watt Fixture Ballast Bulb Sleeve 18Watt Fixture Ballast Lamp Sleeve 9Watt Fixture Ballast Bulb Sleeve Clear Cap I l l u s t r a t i o n P a r t D e s c r i p t i o n 2 7 0 0 5 5 0 0 8 0 0 0 1 6 0 0 0 1 1 2 FITTINGS 2 FITTINGS Included Not Included Sub Assembly INCLUDEDWITH MODELS PARTS LISTING F...

Страница 12: ...s do not constitute warranties and shall not be relied upon by the user and are not part of this contract Neither the seller nor the manufacturer shall be liable for any injury loss or damages direct incidental or consequential including but not limited to incidental or consequential damage for lost profits lost sales injury and inability to use the product and the user agrees that no other remedy...

Отзывы: