Pondmaster 05610 Скачать руководство пользователя страница 8

UV CLARIFIER OPERATING 
INSTRUCTIONS: 

If your pressure filter was supplied with an 

UV clarifier or if you are adding a UV 

Clarifier, note the following: 

The UV Clarifier will not light up when 

removed from the pressure filter cover.  It 

incorporates a safety switch to disable 

power when not assembled. 

To use the UV feature, unscrew the UV cap/

socket assembly from the cover and push 

the bulb into the bulb socket. Carefully 

reinsert the UV bulb straight down into the 

top opening with the quartz sleeve in 

place. Rotate the cap clockwise until tight. 

Plug the power cord into a grounded GFCI 

protected outlet to check. The top of the UV 

cap is clear for observation that UV is 

functioning. Disconnect power until 

the filter is running. 

IMPORTANT NOTES: 

1)

If installing the UV quartz sleeve into the Filter Cover make 

certain that 0-Rings and/or flat gasket are properly installed.

2)

Completely assemble UV Clarifier into filter with Quartz

sleeve installed before supplying power. This will assure that 

safety switch is engaged and unit will light. The light can be

safely checked by viewing through the Clear plastic UV cap on

the fixture.

3)

Never stare at or expose skin to UV light. It can damage

eyesight or burn skin.

4)

Do not defeat the safety features by bypassing the built in

safety switch.

5)

A second port is available to install an additional UV unit.

The 16000 model uses both ports. See Optional Accessories.

Ballast is enclosed in a double insulated case. Never cut power 

cord. Do not modify the plug provided with the appliance; if it 

will  not  fit  the  outlet,  have  a  proper  outlet  installed  by  a 

qualified electrician.

 

NOTE POSITION 

OF O-RINGS 

� 

I

I

,,--1 

"--� 

UV 

FIXTURE 

WITH 

BALLAST 

O-RING UNDER 

TOP FLANGE 

OPEN UV PORT 

ON FILTER 

COVER 

NOTE: YOUR FILTER AND UV ACCESSORIES 

MAY VARY FROM REFERENCE ILLUSTRATION. 

� 

.A 

DANGER: ULTRAVIOLET RADIATION. 

Disconnect Power Before Replacing

Lamp. Connect only to a circuit that is protected by a ground-fault circuit­

interrupter (GFCI). 

WARNING: 

Risk of Electric Shock. Disconnect power before servicing. Do 

not immerse in water. For household use only. 

UV MAINTENANCE 

1) Effective useful bulb life is one season. The bulb will continue to illuminate long after the UV

radiance has diminished. For best results replace bulb annually.

2)

Periodically clean the quartz sleeve.  Always allow unit to cool before disassembly. Carefully

disassemble and clean outside using a solution of 30% white vinegar to water. Allow to soak to

soften scale or build-up.  Use a bottle brush and mild detergent to clean inside of quartz sleeve.

Make certain inside of tube is dry before reassembly. Lubricate 0-Rings with 

Silicone grease

before reassembling. 

NEVER USE PETROLEUM BASED LUBRICANTS ON O-RINGS AND GASKET.

Note that if Quartz sleeve or UV lamp shows any signs of cracks or fissures it cannot be used and 

must be replaced. 

MERCURY WARNING: LAMP CONTAINS MERCURY, MANAGE IN 

ACCORDANCE WITH DISPOSAL LAWS. WWW.LAMPRECYCLE.ORG 

NOTE POSITION 

OF FLAT GASKET AND O-RING

FLAT GASKET 

SEATS  

ON 

TOP 

OF QUARTZ 

SLEEVE

POSITION 

QUARTZ SLEEVE DETAIL

BLACK NECK

QUARTZ SLEEVE DETAIL

CLEAR NECK

ONE O-RING

 

SEATS IN TRACK 

AT TOP OF 

QUARTZ 

POSITION 

O-

O-RING 

RING 

OUTSIDE

SECOND 

O-RING 

THE TUBE 

BELOW THE 

FLANGE

THE TUBE 

BELOW THE 

FLANGE

GASKET OR

QUARTZ SLEEVE WITH 

O-RING /GASKET IN 

PLACE

(SEE DETAIL)

Содержание 05610

Страница 1: ...1 PRESSURIZED POND FILTER CARE AND OPERATING INSTRUCTIONS ZG400 revD 1 18 MODELS ITEM 120V 2700 05610 05615 5500 05620 05625 8000 05630 05635 16000 05640 05645 With UV No UV 230V 05617 05627 05637 ...

Страница 2: ...ding to allow the bacteria colonies to grow The time required varies depending on climate weather conditions fish load and feed rates Until the colonies grow large enough the pond owner must take care to monitor levels of ammonia and nitrates in the water and take appropriate measures to correct any dangerously high levels CAUTION Note that smaller filter media cannot be used with this filter It w...

Страница 3: ......

Страница 4: ...chamber of filter drum Place Foam Filter pad in upper end of filtration chamber CHECKTHAT DRAIN PLUG IS IN PLACE ANDTIGHTENED SECURELY FILTER SET UP Note position of alignment tab on filter drum and matching notch on filter cover Press cover straight down Do not twist or shift as it may unseat the gasket O ring 4 IMPORTANT CLEAN LUBRICATE ALIGN ALIGN COVER NOTCH ONLY LUBRICATEWITH SILICONE GREASE ...

Страница 5: ...ATING INSTRUCTIONS PRESS COVER COMPLETELY DOWN ATTACH RING CLAMP 3 Unions PVC Cement not included Carefully follow the instructions supplied with PVC cement MODEL 16000 MODEL 8000 5500 2700 USE SLIP ADAPTOR ON ALL PORTS O RINGS MUST BE SEATED IN GROOVE ON ALL THREE PORTS USE BARB FOR 3 FLEXIBLE TUBING IT MUST BE CEMENTED TO SLIP ADAPTOR USE COLLAR TO SECURE EITHER BARB FITTING OR SLIP ADAPTOR 3 RI...

Страница 6: ...TING INSTRUCTIONS 1 Put the valve to position 1 FILTER 2 Turn on pump and check all connections Check that pressure gauge pointer is in the Green zone Run filter with Foam Filter pad and Biomatrix Ball media at first The Biomatrix Ball media works best when the filter s bacteria colonies are established It takes a few weeks for the bacterial colonies to grow on the media and be effective for filtr...

Страница 7: ......

Страница 8: ...not fit the outlet have a proper outlet installed by a qualified electrician NOTEPOSITION OF O RINGS t I I 1 UV FIXTURE WITH BALLAST O RING UNDER TOP FLANGE OPEN UV PORT ON FILTER COVER NOTE YOUR FILTER AND UV ACCESSORIES MAY VARY FROM REFERENCE ILLUSTRATION A DANGER ULTRAVIOLET RADIATION Disconnect Power Before Replacing Lamp Connect only to a circuit that is protected by a ground fault circuit i...

Страница 9: ... for winter Cover the open UV port with the clear extra UV port cap that was placed in storage DO NOT ALLOW WATER TO GET INTO UV QUARTZ SLEEVE AND FREEZE IT WILL CRACK WHEN WATER FREEZES CLEARGUARD BACKWASH AIR KIT For more thorough backwashing and agitation in the media filter chamber to break up the stubborn debris It connects though the drain plug at the bottom of the pressure filter UV Clarifi...

Страница 10: ...If still slow make adjustments to set up Outlet is clogged Check for obstructions and clear outlet Filter drum is leaking at perimeter O Ring or Gasket is missing twisted dirty or was not lubricated Turn off pump Open filter and remove clean re seat and lubricate O Ring gasket Attach cover checking alignment of tab slot and thoroughly tighten clamp knob Water pressure is too high Pump is too large...

Страница 11: ...arge Bottom Grid 11 4 BioMatrix Ball Media UV models Only 18Watt Fixture Ballast Lamp Sleeve Clear Cap 9Watt Fixture Ballast Bulb Sleeve 18Watt Fixture Ballast Lamp Sleeve 9Watt Fixture Ballast Bulb Sleeve Clear Cap I l l u s t r a t i o n P a r t D e s c r i p t i o n 2 7 0 0 5 5 0 0 8 0 0 0 1 6 0 0 0 1 1 2 FITTINGS 2 FITTINGS Included Not Included Sub Assembly INCLUDEDWITH MODELS PARTS LISTING F...

Страница 12: ...s do not constitute warranties and shall not be relied upon by the user and are not part of this contract Neither the seller nor the manufacturer shall be liable for any injury loss or damages direct incidental or consequential including but not limited to incidental or consequential damage for lost profits lost sales injury and inability to use the product and the user agrees that no other remedy...

Отзывы: