8
UV CLARIFIER OPERATING
INSTRUCTIONS:
If your pressure filter was supplied with an
UV clarifier or if you are adding a UV
Clarifier, note the following:
The UV Clarifier will not light up when
removed from the pressure filter cover. It
incorporates a safety switch to disable
power when not assembled.
To use the UV feature, unscrew the UV cap/
socket assembly from the cover and push
the bulb into the bulb socket. Carefully
reinsert the UV bulb straight down into the
top opening with the quartz sleeve in
place. Rotate the cap clockwise until tight.
Plug the power cord into a grounded GFCI
protected outlet to check. The top of the UV
cap is clear for observation that UV is
functioning. Disconnect power until
the filter is running.
IMPORTANT NOTES:
1)
If installing the UV quartz sleeve into the Filter Cover make
certain that 0-Rings and/or flat gasket are properly installed.
2)
Completely assemble UV Clarifier into filter with Quartz
sleeve installed before supplying power. This will assure that
safety switch is engaged and unit will light. The light can be
safely checked by viewing through the Clear plastic UV cap on
the fixture.
3)
Never stare at or expose skin to UV light. It can damage
eyesight or burn skin.
4)
Do not defeat the safety features by bypassing the built in
safety switch.
5)
A second port is available to install an additional UV unit.
The 16000 model uses both ports. See Optional Accessories.
Ballast is enclosed in a double insulated case. Never cut power
cord. Do not modify the plug provided with the appliance; if it
will not fit the outlet, have a proper outlet installed by a
qualified electrician.
NOTE POSITION
OF O-RINGS
�
t
I
I
,,--1
"--�
UV
FIXTURE
WITH
BALLAST
O-RING UNDER
TOP FLANGE
OPEN UV PORT
ON FILTER
COVER
NOTE: YOUR FILTER AND UV ACCESSORIES
MAY VARY FROM REFERENCE ILLUSTRATION.
�
.A
DANGER: ULTRAVIOLET RADIATION.
Disconnect Power Before Replacing
Lamp. Connect only to a circuit that is protected by a ground-fault circuit
interrupter (GFCI).
WARNING:
Risk of Electric Shock. Disconnect power before servicing. Do
not immerse in water. For household use only.
UV MAINTENANCE
1) Effective useful bulb life is one season. The bulb will continue to illuminate long after the UV
radiance has diminished. For best results replace bulb annually.
2)
Periodically clean the quartz sleeve. Always allow unit to cool before disassembly. Carefully
disassemble and clean outside using a solution of 30% white vinegar to water. Allow to soak to
soften scale or build-up. Use a bottle brush and mild detergent to clean inside of quartz sleeve.
Make certain inside of tube is dry before reassembly. Lubricate 0-Rings with
Silicone grease
before reassembling.
NEVER USE PETROLEUM BASED LUBRICANTS ON O-RINGS AND GASKET.
Note that if Quartz sleeve or UV lamp shows any signs of cracks or fissures it cannot be used and
must be replaced.
MERCURY WARNING: LAMP CONTAINS MERCURY, MANAGE IN
ACCORDANCE WITH DISPOSAL LAWS. WWW.LAMPRECYCLE.ORG
NOTE POSITION
OF FLAT GASKET AND O-RING
FLAT GASKET
SEATS
ON
TOP
OF QUARTZ
SLEEVE
POSITION
QUARTZ SLEEVE DETAIL
BLACK NECK
QUARTZ SLEEVE DETAIL
CLEAR NECK
ONE O-RING
SEATS IN TRACK
AT TOP OF
QUARTZ
POSITION
O-
O-RING
RING
OUTSIDE
SECOND
O-RING
THE TUBE
BELOW THE
FLANGE
THE TUBE
BELOW THE
FLANGE
GASKET OR
QUARTZ SLEEVE WITH
O-RING /GASKET IN
PLACE
(SEE DETAIL)