Positioning of your pump

YOU MUST DISCONNECT THE POWER 
SUPPLY BEFORE CARRYING OUT ANY 
MAINTENANCE WORK OR HANDLING THE 
PUMP IN ANYWAY. 

All Shark models are suitable for dry installation 
outside of the pond. For example connecting to 
a gravity fed filter (see diagram below). 

NOTE

the pump 

MUST

 always be installed below 

water level, in a well ventilated area and on a 
flat level surface were it does not have to “suck” 
water up to the inlet. It 

MUST ALWAYS

 have 

unlimited flow of water into the pump. To 
connect in a dry sited location the strainer will 
need to be removed from the pump. The inlet of 
the pump has a threaded connection, ensure 
the corresponding pipe work matches. Avoid 
using pipe or fittings smaller than the inlet of the 
pump, this will damage the pump. 

DO NOT 

USE

 a valve or tap on the inlet of the pump 

restriction of flow can only be done on the outlet 
side of the pump. 

Under normal circumstances your pump should 
start immediately. If it does not, then some 
possible explanations could be: 

Lack of back pressure on the pump. Place a 
hand over the end of the hose to create back 
pressure until water flows. 

Occasionally the impeller may stick from new. 
This is a result of the amount of time the pump 
has sat in a box since production and is 
perfectly normal. If this happens 

ALWAYS 

switch the pump off from the mains power 
supply before handling it in any way. Turn the 
impeller with a tool like a screw driver to release 
it. Submerse back into position and switch on. 

DO NOT ATTEMPT TO TURN THE IMPELLER 
WITH YOUR FINGERS. 

To maximise the life of your pump it is 
recommended to clean the pump casing and 
the impeller every 4-8 weeks or earlier if flow 
has decreased significantly.  

Prior to cleaning, disconnect the pump from the 
electrical power supply. 

The casing of the pump can be cleaned with a 
firm brush. 

DO NOT USE DETERGENTS AS 

THE USE OF THESE WILL BE POTENTIALLY 
LETHAL TO POND INHABITANTS.

 Leaves, 

grass and algae should also be removed.

Should you need to access the impeller follow 
the instructions under the section headed 
“Accessing the Impeller” in this instruction 
booklet.

7

Pump Maintenance / Cleaning 

Notes

Starting Your Pump 

Содержание Shark 4500

Страница 1: ...Instruction Manual Shark Models 4500 5500 7500 9500 ...

Страница 2: ... supposed to be wet Do not operate the appliance if it has a damaged power supply cord or plug or it is malfunctioning or has been dropped or damaged in any manner If the plug or socket does get wet do not unplug or disconnect the appliance from the socket Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket To ...

Страница 3: ...flexible cable or cord of this pump cannot be replaced If the cord is damaged the pump should be scrapped 2 Use Pond One Genuine Spare Parts Only See your local Pond One Dealer and look for the number listed below for the spare part you require Alterna tively you will find these numbers on the red label located on the product Replacement Parts 3 Precision Manufactured in the P R C Designed in Aust...

Страница 4: ... the grass A approved earth leakage circuit breaker RCCB or otherwise known as an Residual Circuit Current Device RCCD must be fitted in the supply line The appliance should be connected to the mains supply using the following colour coding Refer to Diagram 1 Red or brown wire to the live connection L Blue or black wire to the Neutral connection N Green with Yellow stripe wire to the Earth connect...

Страница 5: ...Know Your Pump 2 5 1 Strainer 2 Impeller Cover 3 O ring 4 Impeller 5 Handle 6 Motor 7 Motor Cover 8 Screws 9 Impeller Blades 10 Rotor 1 2 3 4 5 6 7 8 9 10 ...

Страница 6: ...water Installation Please refer to the following page for suggested installation of the fountain head fittings which are supplied with your pump Your Shark pump is supplied with a stepped hose tail which can be attached to the flow control adjuster and used to run a waterfall or second feature Simply remove the blanking plug and attach the stepped hose tail then press your selected hose onto the s...

Страница 7: ...ossible explanations could be Lack of back pressure on the pump Place a hand over the end of the hose to create back pressure until water flows Occasionally the impeller may stick from new This is a result of the amount of time the pump has sat in a box since production and is perfectly normal If this happens ALWAYS switch the pump off from the mains power supply before handling it in any way Turn...

Страница 8: ...room outlet 2 Two tiered fountain head 3 Extension tube 4 Flow control adjuster 5 Tap 6 Blanking nut 7 Stepped hose tail 8 Fountain adaptor 9 Reducer 10 Shark pump Shark 4500 5500 7500 9500 1 2 3 4 5 6 7 8 9 10 ...

Страница 9: ... do not use any tools as you may damage the impeller 6 You will notice the impeller has an odd shaped rubber seal on it Remove this prior to cleaning 7 Clean the impeller and the rotor chamber with a smooth cloth only DO NOT use abrasive scouring pads or implements Ensure the grid which sits at the front of the impeller is free from debris This is very important Its location is indicated by the ar...

Страница 10: ...cleaning and maintenance instructions Calcium Limescale Pump output can also be reduced by the effects of limestone or calcium build up especially in hard water areas Pumps should therefore be descaled regularly to maximize life expectancy Procedure Disconnect power supply remove pump from pond and remove the impeller The whole motor and impeller should be immersed in a suitable descaling agent li...

Страница 11: ...tions or this Guarantee Pond One reserves the right to terminate Extended Guarantee for such goods and will provide written notice to the purchaser 3 0 Exclusions and Limitations Where permitted by local law the following exclusions and limitations apply in regard to the Guarantee 3 1 Goods claims where fault is due to but not limited by a misuse b neglect c abuse d fire or flood e normal wear and...

Страница 12: ... first fish was introduced Gravel Substrate Filtration Information Filter Type Flow Rate Filter Media Biological Mechanical Chemical Other Pond Accessories Power Heads Brand Flow rate Air Pumps Brand Output Ultra Violet Clarifier Brand Size Other Fish Information Type of Fish Size Date Added 12 Pond Log Instruction Version 21 01 08 ...

Отзывы: