Operating manual liquid ring vacuum pumps TRVK - TRSK
18
9.3.3 - Service liquid: Total recovery system
This system has total recycle of the service liquid
without fresh liquid make-up from an outside
source.
A heat exchanger is required to lower and control
the temperature of the recycled service liquid: for
sizing and calculations of heat loads consult
Pompetravaini.
A circulating pump will be required for those
applications where the vacuum pump operates for
extended period of times in the pressure ranges
above 400/600 mbar or when there are high
pressure drops in the closed loop including the
heat exchanger (over approximately 1.5 m).
The liquid level in the separator tank should not be
above the pump shaft centreline.
Losses of liquid from the closed loop must be
compensated with an equal amount from an
outside source.
Schematic fig. 20 illustrates the system with total
recovery of the service liquid.
9.4 - PUMP ENGINEERING DATA
Tab. 3
PUMP MODEL
W
e
igh
t,
B
are
pu
m
p
Operating Speed
RPM
Installed
Motor size
kW
Installed Motor
Frame size
(indicative)
Weight of
Electric Motor
(indicative)
kg
kgs
from
to
from
to
from
to
from
to
TRVK 1502/1
850
565
880
30
55
200L
250M
260
410
TRVK 1503/1
1043
590
920
45
90
225M
280M
320
650
TRVK 2003/1
705
500
740
55
110
250M
315S
410
1000
TRVK 2503/1
790
370
660
75
160
280S
315L
550
1160
TRVK 3003/1
1060
370
530
132
250
315M
355M
1100
1700
TRVK 3503/1
1005
270
470
160
315
315L
355L
1160
1850
TRVK 4003/1
1130
240
400
200
500
315L
450
1270
3020
TRVK 5003/1
1295
210
330
315
630
355L
450
1850
3430
TRSK 2002/1
1470
472
640
55
75
250M
280S
410
550
TRSK 2004/1
1850
490
640
75
110
280S
315S
550
1000
TRSK 2005/1
1680
470
740
55
110
250M
315S
410
1000
TRSK 2502/1
2400
385
510
90
132
280M
315M
650
1100
TRSK 3000/1
3050
372
550
110
200
315S
315L
1000
1270
TRSK 3002/1
3300
330
472
110
160
315S
315L
1000
1160
TRSK 3004/1
3600
330
472
132
250
315L
355M
1270
1700
TRSK 3006/1
4000
350
420
90
250
280M
355M
650
1700
TRSK 3500/1
4350
330
490
160
315
315L
355L
1160
1850
TRSK 3504/1
5600
266
372
160
250
315L
355M
1160
1700
TRSK 4000/1
6560
276
395
200
400
315L
400L
1270
2260
TRSK 4002/1
7900
220
298
200
315
315L
355L
1270
1850
TRSK 4004/1
8600
220
298
200
355
315L
400
1270
2260
TRSK 4504/1
10200
236
330
315
500
355L
450
1850
3020
TRSK 5002/1
11500
197
276
315
500
355L
450
1850
3020
TRSK 5004/1
12500
220
298
400
630
400
450
2260
3430
TRSK 5008/1
13950
197
312
400
710
400
450
2260
3650
Fig. 20
Содержание TRSK 2002/1
Страница 1: ... NA4 IS VUOC IN00 Rev 3 8_11 2020 OPERATING MANUAL LIQUID RING VACUUM PUMPS TRVK TRSK ...
Страница 10: ...Operating manual liquid ring vacuum pumps TRVK TRSK 10 90 OK NO Fig 2 Fig 4 Fig 1 Fig 3 ...
Страница 28: ...Operating manual liquid ring vacuum pumps TRVK TRSK 28 blank page ...
Страница 29: ...Operating manual liquid ring vacuum pumps TRVK TRSK 29 blank page ...
Страница 30: ...Operating manual liquid ring vacuum pumps TRVK TRSK 30 blank page ...