Integrative notes to the operating manual for magnetic coupling centrifugal pumps conforming to the ATEX 94/9/CE directive TCK... - TBK... – TBAK… 

7

ALWAYS

 follow the performances and the intended use in our Confirmation of order for the pump involved. 

-  The electric connections on the pump motor must 

ALWAYS

 be carried out by authorized and skilled persons who 

must observe the provisions in force. 

-  Any job on the pump must

 ALWAYS

 be carried out in the presence of at least 2 persons. 

-  The pump must 

ONLY

 be approached by a person wearing suitable garments (garments with large sleeves, ties, 

necklaces, etc. must be avoided) and/or using other protective items (helmets, goggles, gloves, special footwear, 
etc.) which are suitable for the jobs to be carried out. 

ALWAYS

 be informed about the places for first aid inside of the company. Furthermore, read carefully the safety and 

the first-aid rules in force. 

ALWAYS

 disconnect the pump from the plant and switch the electric power off before any intervention on it. 

-  The pump must 

ALWAYS

 be stopped before the operator touches it for whatever reason. 

-  The pump must 

ALWAYS

 be cool or cooled down before doing any maintenance job on it. 

NEVER

 remove the safeguards from any rotary parts of the pump when it is running. 

ALWAYS

 remount the safeguards, which for whatever reason have been removed, as soon as the reason for this 

removal has ceased. 

NEVER

 touch the pump or the pipes connected to it when hot liquids over 80°C are conveyed. 

ALWAYS

 pay much attention when touching a pump which conveys or has conveyed toxic or acid liquids. 

ALWAYS

 have fire-preventing equipment available in the immediate vicinity. 

NEVER

 run the pump into the opposite 

direction

 of rotation than the one marked directly on the pump. 

NEVER

 put hands or fingers into the holes or openings of the electric pump unit. 

NEVER

 climb on the pump or the pipes connected with it. 

- The pump and pipes fitted to it must 

NEVER

 be under pressure during any maintenance job on it. 

NOTE: Inside the pump there are components which may present a hazard to persons who are exposed to  

them also during the normal procedures of use or maintenance. See the following table 

(Tab. 3)

Tab. 3 

MATERIAL 

USE 

MAIN HAZARDS  

Oil and grease 

General lubrication, rolling bearings 

Irritation of skin and eyes 

Components made of 
plastics and elastomers 

O-Ring, V-Ring, lip seal-rings, 
splashguards  

Release of fumes in case of heating  

Synthetic fibres 

Tress rings 

Emission of toxic dust, release of fumes in case of 
heating 

Paint 

Outside surface of the pump 

Release of dust and fumes during operation, 
flammability. 

Protective liquid 

Inside surface of the pump 

Irritation of skin and eyes 

The non observance of the instructions shown 

i

n this booklet or in the Operator’s Manual of the

 

pump exempts POMPETRAVAINI from any responsibility in case of damage to objects or injuries

 

to persons and makes any safety compliance for the pump invalid. 
This booklet deals with the hazards when using this pump in 

environment

 of potentially 

explosive atmospheres. The use of the centrifugal pump however cannot be considered 
without any risk

 

coming from its use as the machine is provided with moving 

components, electrical

 

connections, liquids under pressure etc. Independent from the safety 

guarantees 

which come by 

observing the aforesaid indications, there might be some 

amount

 

of risk which cannot be reasonably foreseen. Only the end-user in the context of his analysis 
and classification of the

 

zones according to the provisions of the ATEX 1999/92/EC Directive 

may be aware of them. The

 

safety during the use of the centrifugal pumps cannot be 

separated completely from any

 

responsible use of the machine, of its accessories and of 

the plant to which these items are

 

connected. 

For maintaining the validity of the safety guarantees of the pump, only original spare parts from 
POMPETRAVAINI must be used. POMPETRAVAINI does not take any responsibility when non-
original spare parts, components, accessories or those not authorized by POMPETRAVAINI are 
used on the pump. POMPETRAVAINI does not take any responsibility if any kind of modification 
is carried out on the pump, its components and accessories which has not purposely 
authorized.

3 – EVENTS OF EMERGENCY 

If there is any malfunction on the pump or leakage of liquid conveyed, switch the electric voltage immediately off and 
follow the correct procedure for cut-out (see Chapter 11 of the Operator’s Manual). Then inform the personnel 
responsible for the plant. At least two persons must act with the necessary attention according to the case, as the pump 
may convey dangerous liquids and/or liquids which may be hazardous to persons and to the 

environment

After having solved all troubles which have generated the emergency, all necessary tests for restarting the electric pump 
unit must be carried out (see Chapter 10 of the Operator’s Manual). 

Содержание TBAK Series

Страница 1: ...INTEGRATIVE NOTES TO THE OPERATING MANUAL FOR MAGNETIC COUPLING CENTRIFUGAL PUMPS CONFORMING TO THE ATEX 94 9 CE DIRECTIVE TCK TBK TBAK ...

Страница 2: ...ecessary for safety on use of the centrifugal pumps in a potentially explosive atmospheres Chapter 9 of this booklet must be read understood and countersigned by the persons in charge with the reading and the application of this supplement to the Operator s Manual of the centrifugal pumps POMPETRAVAINI does not assume any responsibility either for the use of this pump in any applications different...

Страница 3: ...ning 6 3 1 Dry running 6 3 2 Loosening of the coupling assembly screws 6 3 3 Over power transmission 6 3 4 Functioning with vibrations 7 Operational risks 7 1 Intake of foreign bodies 7 2 Dry running 7 3 Operation against obstruction at the delivery side 7 4 Lubrication 7 4 1 Oil lubrication 7 4 2 Grease lubrication 7 5 Operation with hot liquids 7 6 Operation in presence of cavitations 7 7 Operat...

Страница 4: ... and conscientious mode for the kind of application and in the operating conditions specified in the Confirmation of order They may be not safe in case of any malfunction even foreseeable ones ATTENTION The pumps series TCK TBK TBAK generate a strong magnetic field The maximum caution and care must be taken by the possible risk personnel for example carrier of pace maker in charge of use and maint...

Страница 5: ...ll satisfy the user s need for information If there is any matter requiring more details please contact POMPETRAVAINI for further explanations Fig 3 EXAMPLE OF SERVICE CARD POSITION Service Card 1 1 ATEX 94 9 EC DIRECTIVE The ATEX 94 9 EC Directive defines that all equipment intended for use in ambient of potentially explosive atmospheres must be classified into Groups and Categories according to ...

Страница 6: ... specific ignition temperature which when reached is sufficient to cause a fire or an explosion of the mixture The value of this temperature threshold depends on different factors among which the percentage of air and gas dust fuel present in the atmosphere the ambient pressure the ambient humidity the formation of mixture layers or dust deposits etc All this information is not known to POMPETRAVA...

Страница 7: ... Ring lip seal rings splashguards Release of fumes in case of heating Synthetic fibres Tress rings Emission of toxic dust release of fumes in case of heating Paint Outside surface of the pump Release of dust and fumes during operation flammability Protective liquid Inside surface of the pump Irritation of skin and eyes The non observance of the instructions shown in this booklet or in the Operator...

Страница 8: ...rried out according to the instructions shown in Chapter 7 under paragraph 7 1 of the Operator s Manual In case of pumps in enbloc version or pumps fitted to the base supplied already with assembled electric motor checking of alignment must be carried out before starting the pump For this purpose follow the instructions shown in Chapter 7 under paragraph 7 2 of the Operator s Manual If the pumps a...

Страница 9: ...pling to the electric motor is misaligned may cause trouble to the mechanical sealing system and therefore cause leakage of the liquid pumped In this case the sealing system must be replaced as described in the Instructions for Disassembly and Assembly of the Single stage Centrifugal Pumps Furthermore any run with coupling errors will cause heavy vibrations which might cause seizing or even breaka...

Страница 10: ...ried out on the appropriate plate at one side of the base Fig 6 In order to enable the electric continuity between the grounding cable and the pump the paint in the contact area between the plug for the grounding cable and the base plate must be scraped off The point of preparation is put into evidence by a triangle yellow which shows the symbol black of grounding Fig 7 After the connection use an...

Страница 11: ...VAINI the instruction Manual supplied by the motor manufacturer is always enclosed The connection of the electric motor must be carried out according to the instruction manual of the motor manufacturer This manual must be carefully preserved together with the one of the pump If the manual for the electric motor is not available when carrying out the connections please contact POMPETRAVAINI 5 4 DIR...

Страница 12: ... magnetic coupling 6 1 CHECKINGS ON THE RUNNING The correct running of magnetic coupling pumps ask for a special attention to the coupling qualities that has particularly frail components The pump start must be executed according to the instructions reported in the Operating Manual supplied with the pump An incorrect execution of the pump start up procedure could lead to a mechanical damage of the...

Страница 13: ...of the rotor are build of relatively frail material and are assembled with tight assembling tolerances The presence of vibrations could cause impacts or frictions that compromises the life of the coupling system and the pump integrity The installation of a vibrations monitoring system is useful to signal the possibility of a mechanical problem on the pump as a result of hydraulic malfunctioning or...

Страница 14: ... conforming to the ATEX 94 9 CE directive TCK TBK TBAK 14 Fig 8 SAMPLE OF A SECTION OF PUMP SERIES TCK CAN INTERNAL ROROR S BUSHINGS INTERNAL MAGNETS POSSIBLE AIR FLOW INLET THERMAL PROBE POSITION EXTERNAL MAGNETOS VAPOR EXIT OPENING LIQUID LOOSE DRAIN OPENING POSSIBLE AIR FLOW EXIT ...

Страница 15: ...ified 6 2 3 Functioning with presence of vibrations The pumps with magnetic coupling must NEVER run in presence of vibrations or suffer vibrations during transport storage or any other moment of non running It is recommended to not let the pumps suffer vibrations higher than 1 5 mm sec and in any case NEVER above 2 2 mm sec The magnetic coupling components are assembled with tight tolerances and a...

Страница 16: ...s conforming to Group II Category 2 but it is also very much advisable on pumps of Group II Category 3 The installation of a measuring instrument for the out flowing delivery rate from the pump is advisable to prevent operation against any obstruction on the delivery side as described in the following paragraph 7 3 These accessories must be chosen among the ones certified according to the ATEX 94 ...

Страница 17: ...e mechanical consequences are high vibrations and the risk of seizing 7 4 LUBRICATION 7 4 1 Oil lubrication The pump must NEVER run without a sufficient quantity of lubricant oil inside of the journal The indications for a correct lubrication are shown in Chapter 13 of the Operator s Manual The bearing of the pump is cooled by the air flow generated by the electric motor for cooling the motor down...

Страница 18: ...emperature reached by the pump body For this purpose read carefully the contents of Chapter 6 of this booklet regarding the mechanical sealing system RESIDUAL RISK When the pump is used for pumping liquids at high temperatures its surface temperature practically is equal to the liquid pumped The compatibility between the temperature of the liquid pumped the mechanical features of the pump and the ...

Страница 19: ...tion of order for which POMPETRAVAINI has provided the execution the materials used for manufacturing and the test runs which make the pump to be perfectly corresponding to the requirements Therefore the pump MUST NOT be utilised for different applications In any other case please contact POMPETRAVAINI who declines any responsibility for any use different from the foreseen one when the respective ...

Страница 20: ...instruction manuals needed for the pump By compiling the table underneath this is to confirm to have read the entire contents of this booklet and of the Operator s Manual for of the centrifugal pumps and to have understood it under all aspects and to be conscientious of all conditions of risk when using the pump and to actuate all the indications for the safest and best use POMPETRAVAINI does not ...

Отзывы: