background image

 

 

  HDI 2 multi 

  

IP Modulator  

   

IP into DVB-C / DVB-T / ISDB-T

 

 

 
 
 
 
 

 

 
 
 
 
 
 
 

Manual 

 

 
 

0902252 V1     

Содержание HDI 2 multi

Страница 1: ...1 HDI 2 multi IP Modulator IP into DVB C DVB T ISDB T Manual 0902252 V1...

Страница 2: ..._________________________________________16 6 8 2 Menu item Change password ___________________________________________16 6 8 3 Menu item User management ___________________________________________17...

Страница 3: ...dripping and splashing water If there is condensation wait until the device is completely dry Operating environment according to the specified IP protection class Caution Danger of life According to t...

Страница 4: ...efined packing and transportation materials Damage caused by faulty connections and or improper handling are excluded from any liability Waste disposal Electronic equipment does not belong in househol...

Страница 5: ...easy programming The management and the connection of the IP transport stream takes place via an RJ45 100Mbit s interface The IP modulator offers the possibility to feed IP camera signals into the cab...

Страница 6: ...connect the modulator s power supply to the mains until all cables are fully connected to the modulator 6 Programming via the Ethernet interface NMS Changes to the basic configuration can only be done...

Страница 7: ...device homepage will display the main information about the device and its status File tabs for programming the HDI 2 multi are available at the top of the window In the device description Device info...

Страница 8: ...ndicates that no valid stream has been detected In the field Bitrate the measured input bitrate of the stream in Mbit s will be displayed The CC errors field displays continuity counter errors detecte...

Страница 9: ...to give all inserted cameras a name under the item Title If the camera requires a password the fields Username and Password must be completed If all fields have been completed correctly click the but...

Страница 10: ...ates the actual input bit rate of the service in Mbit s Under LCN v 1 a logical channel number can be assigned for the service If the TV supports LCN the services will be sorted by this number Zero me...

Страница 11: ...activated If a different value is desired clear this check box and enter the value manually Normally the Original network ID is the same for all output channels throughout the network Exact values ca...

Страница 12: ...the reduction of the RF output level and can be set via Output 1 for both output channels Selection 0 30 dB 1 dB steps Enable By selecting the check box the output channel will be activated Selection...

Страница 13: ...vated If all fields have been completed correctly press the button Update and the data will be sent to the device DVB C Annex B RF parameters In this menu the DVB C Annex B RF parameters of the output...

Страница 14: ...ly programmable for each RF channel Selection 1 2 2 3 3 4 5 6 7 8 Frequency kHz The output frequency for Output 1 will be set in this column The output frequency for Output 2 will be automatically pro...

Страница 15: ...password will be reset to factory settings status LED will flash red and green and the device will be restarted with the default IP address and password admin Press for 4 seconds all parameters will b...

Страница 16: ...can change his username and password After pressing the item Change password the following window for changing the password will be opened Only the dedicated username admin cannot be changed All other...

Страница 17: ...n Note Use the exported file to import parameters only to another device with the same modulation type or to the same device 6 8 5 Menu item Import of parameters Exported parameters from one HDI 2 mul...

Страница 18: ...which the file was exported Press the button Upload to send the parameters to the device The import of parameters from one software release to another is also allowed New parameters or parameters tha...

Страница 19: ...s in process The login window will appear on the screen once the firmware upgrade is complete The browser does not need to be updated All device settings remain unchanged 6 8 7 Menu item Restart the d...

Страница 20: ...ill be accepted 6 8 11 Menu item Date time In the menu item Date time in the tab System menu the user can specify the time source for the IP modulator Local time shows the time taking into account pos...

Страница 21: ...2 2 3 3 4 5 6 7 8 Symbol rate 1 7 2 MSps 5 057 6 36 MSps FFT 2K MER 40 dB 35 dB 40 dB Number of channels 2 Channel allocation Adjacent channel Output level 90 dB V Attenuator 0 30 dB 1 dB steps Connec...

Страница 22: ...22 Notes...

Страница 23: ...23 Notes...

Страница 24: ...hme H Q Order department 49 0 70 81 1702 0 Technische Hotline Technical hotline 49 0 70 81 1702 0 Telefax 49 0 70 81 1702 50 Internet http www polytron de Email info polytron de Technische nderungen v...

Отзывы: