LAB1238R Householder Instructions, Issue 1, April 2016
Page 2
General Warnings & Safety Information
IMPORTANT!
PLEASE READ THESE INSTRUCTIONS CAREFULLY
1. Do not use this appliance in areas where the following may be present or occur:
Excessive oil or a grease laden atmosphere
Corrosive or flammable gases, liquids or vapours
Be subject to direct water spray
Ambient temperatures higher than 50°C and lower than -25°C
Possible obstructions that may hinder access or removal of the unit
2. This fan can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play
with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
General
Your Silavent HRX-aQ appliance is a key part of a whole house ventilation system specifically
designed to improve indoor air quality in dwellings. The system is designed to provide measured
amounts of filtered, fresh air to living areas while constantly removing polluted, stale air from
bathing, cooking and washing areas at the same gentle rate.
Any available heat in the outgoing
stale air is recovered by a built-in heat exchanger and used to pre-warm the fresh supply air.
A programmable user interface has been provided to help maintain a comfortable indoor
environment which includes the following features:
Time and date functions
Filter check reminder
Fingertip fan control; Low, Boost, Max
Automatic, summer heat exchanger-bypass operation
Automatic humidity level boost-switching
Your system may also have been wired to trigger Boost from a lighting circuit or a number of
lighting circuits.
The two filters in the appliance ensure that the fresh supply air is clean as it enters the home.
Additionally, the stale extract air is filtered to protect the heat exchanger from unwanted
contamination. These filters have to be cleaned regularly, depending on the levels of pollution. The
filters should be replaced when they start to show visible signs of wear.
AQH200-B and AQH240-B models are fitted with a fully automatic heat exchanger bypass
mechanism. The bypass will operate when the indoor target temperature reaches a pre-set value.
Using the digital user-interface, the trigger temperature for this operation can be set between
+15°C and 25°C.
Further details regarding your system are contained in the full installation manual which should
accompany this abridged householder guide.