LAB1238R Householder Instructions, Issue 1, April 2016

   

 

Page 6 

 
 
Creating bespoke heat exchanger bypass timed programmes 
 
Each of the programmes can be 

edited

 to create bespoke programmes as follows: 

 

Press “PROG”. 

 

Use the “+” and “-“ buttons to select the programme number (Factory default is P9). 

 

Press “PROG”. The programme number will stop flashing and the first block on the timeline at the 
bottom of the screen will begin to flash. 

 

Select the day to be edited by pressing “DAY” until the correct day is displayed along the top of the 
screen (1 – Monday, 2 – Tuesday etc.). 

 

To add a 30 minute temperature controlled bypass block (a black square) to the timeline, ensure 
that the word “BYPASS” is displayed on the screen by pressing “BYPASS”.  

 

Press the “+” and “-“ buttons to move along the timeline at the bottom of the screen; a block will 
be 

added

 to each position.   

 
To remove a block, remove the word “BYPASS” from the screen by pressing “BYPASS” and press the 
“+” and “-“ buttons to move along the timeline at the bottom of the screen; a block will be 

removed

 from each position. 

 
Daily ‘timeline patterns’ can be 

copied

 to another day or multiple days to avoid programming each 

day individually. 
 
From the home screen press “COPY” then select the day to copy by pressing “PROG” (the day 
number will be displayed) and then the day to copy-to by pressing the “+” and “-“ buttons (the day 
number will flash).  When the two correct days have been selected, press “COPY” and the timeline 
pattern will copy across. 
 
Press “SET” to record. 

 

Filter maintenance 
 
The two filters should be cleaned on a regular basis; the exact frequency will be determined by 
individual living conditions. 
 
The word ‘Filter’ will appear on the home screen of the digital user-interface after the set time has 
elapsed - when this occurs, clean the filters – see page 4 for resetting details. 
 
To remove the two filters, pull out the two caps from the front of the appliance and gently slide out 
the filters in their carrier frames. 
 
Lightly vacuum the filters to remove surface debris and then gently wash through in warm soapy 
water. Ensure that the filters are completely dry before refitting. Important: do not dry on a 
radiator or use excessive heat as this may distort the carrier frames. 
 
Faults 
 
If the digital display shows ‘Fault’ and either ‘Fan 1’ or ‘Fan 2’, there is a potential fault with one of 
the fans. If the digital display shows ‘Fault’ only, the external system inhibit may have been 
activated. In either case, in the first instance, contact your building services management team. 

Содержание Silavent HRX-aQ

Страница 1: ...nstructions must be given to the householder DO NOT SWITCH OFF THE UNIT it is designed to run continuously If the unit is switched off indoor pollutants and moisture levels may increase which could en...

Страница 2: ...bathing cooking and washing areas at the same gentle rate Any available heat in the outgoing stale air is recovered by a built in heat exchanger and used to pre warm the fresh supply air A programmabl...

Страница 3: ...ime Humidity level Speed Exhaust temperature Frost protection active Programme number Intake temperature Date Heat exchanger bypass active Half hour time switch segments Further details regarding your...

Страница 4: ...ilters see page 6 To reset the filter elapsed time reminder following cleaning press and hold SET for 5 seconds Time and date setting this action will be required following a power cut From the home s...

Страница 5: ...H recommended Use the or buttons to set the humidity switching level in steps of 1 RH range 30 85 RH Press SET to record or ESC to discard the settings and return to the home screen Selecting the heat...

Страница 6: ...idually From the home screen press COPY then select the day to copy by pressing PROG the day number will be displayed and then the day to copy to by pressing the and buttons the day number will flash...

Страница 7: ...LAB1238R Householder Instructions Issue 1 April 2016 Page 7...

Страница 8: ...Industrial Estate Kirk Sandall Doncaster DN3 1QR UK Tel 44 0 3443 715523 Fax 44 0 3443 715524 International Tel 44 0 1302 348878 International Fax 44 0 1302 348879 Email vent info polypipe com Web ww...

Отзывы: