Overview 
 

The Silavent AMIE control module provides enhanced control of air quality in domestic 
indoor environments serviced by Mechanical Ventilation with Heat Recovery (MVHR). 
 
Silavent AMIE offers a choice of manual or fully automatic control of the two main 
functions: extract fan boost speed operation and heat exchanger bypass (summer 
bypass). 
 
The extract fan boost speed is controlled by humidity level sensing or an external trigger 
such as a switch or push button. Humidity level sensing will change the fan speed from 
background to boost as the level of humidity changes.  The external trigger will change 
the fan speed depending on its on/off condition. When switched off from on, a 15 
minute run on timer is activated; subsequently the MVHR unit will return to background 
speed after 15 minutes unless the external trigger is operated during this time. 
 
Heat exchanger bypass (summer bypass – no heat recovery) is controlled by room 
temperature or time clock settings. In room temperature mode the bypass will change 
from off to on when the room temperature exceeds the set temperature. In time clock 
mode the bypass operation is controlled by pre-programmed or user programmed time 
settings. 
 
 
 
 

IMPORTANT! 

This appliance does not add a heating or refrigerant cooling function to the MVHR 
system. The cooling function provided is the operation of the bypass mechanism of the 
MVHR unit, which diverts air around the heat exchanger. 
 
This appliance can be used by children aged from 8 years and above and persons with 
reduced physical, sensory or mental capabilities or lack of experience and knowledge if 
they have been given supervision or instruction concerning use of the appliance in a safe 
way and understand the hazards involved. Children shall not play with the appliance. 
Cleaning and user maintenance shall not be made by children without supervision. 
 
Before commencing any work read the following instructions carefully and ensure you 
have the necessary competency to complete the work safely. 
 
 

WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK 
 

Содержание Silavent AMIE

Страница 1: ...Email vent info polypipe com 1 Website www polypipe com ventilation LAB1191R Issue 1 May 2015 Silavent AMIE Air Quality Management for Indoor Environments...

Страница 2: ...summer bypass no heat recovery is controlled by room temperature or time clock settings In room temperature mode the bypass will change from off to on when the room temperature exceeds the set temper...

Страница 3: ...tallation 2 1 Installing batteries 2 2 Time and date adjustment 3 Selecting a pre set programme 4 User defined programmes 4 1 Creating a user defined programme 5 Temperature and humidity settings 6 Op...

Страница 4: ...ontrols 1 1 Battery and keyboard access 1 2 Display keyboard and status LED Minus key Plus key Validation key status LED Navigation key left Escape key Programme key Navigation key right Programme num...

Страница 5: ...th the OK OK OK OK key The display will jump automatically to the next value Note you can return to the previous value by pressing on the escape key at any time Sequence of the adjustments Time and da...

Страница 6: ...l next setting Intermediate step heat recovery on temperature controlled bypass activated What time do you require heat recovery to start again during the day Temperature Temperature Temperature Tempe...

Страница 7: ...OK OK to validate and move to the following step The pictogram will blink meaning that you can toggle between and with or Choose and press OK OK OK OK to validate and then adjust the hour of this step...

Страница 8: ...and move to finish the programme setting of day 1 Monday You can now choose to copy the program just created to subsequent days To copy the programme to the next day press OK OK OK OK Should you wish...

Страница 9: ...ting modes 6 Operating modes 6 Operating modes The AMIE control has three selectable operating modes Use the navigation keys to move the cursor between modes Select the mode with the OK OK OK OK key 6...

Страница 10: ...ate timed override press the or key immediately after pressing the OK OK OK OK key to enter the mode The temperature set point value will blink and is adjusted with the keys and Once the adjustment is...

Страница 11: ...The AMIE control has the option to provide a filter cleaning reminder every 3 000 hours approximately 4 months Contact our technical department on 08443 715523 for more information about activating t...

Страница 12: ...ith cooler air through the night as the external air temperature falls making a more comfortable environment for the occupants to get a good night s sleep In addition the fabric of the property will a...

Страница 13: ...Email vent info polypipe com 13 Website www polypipe com ventilation LAB1191R Issue 1 May 2015...

Страница 14: ...lations BS7671 The electrical installation should be inspected and tested by a suitably qualified person after completion When installing the appliance care should be taken not to damage any hidden ut...

Страница 15: ...5 C to 37 C User adjustable humidity setting range 0 RH to 99 RH Electrical protection Class II IP30 Power supply 2 x AAA alkaline battery Estimated battery operating life 2 years Output 2 x volt fre...