1. Once the pump
3
has been removed from the canister
9
you are ready to inspect or replace your rotor assembly .
2. Refer to below pump motor assembly illustration to replace the rotor assembly .
3. Remove the volute cover by unscrewing the volute cover lock nut that hold down the volute cover and pull out the rotor assembly . Please be careful
as the rotor assembly has multiple parts which may come out separately. (see image below)
4. Inspect the rotor assembly to make sure that it has all of its parts and that the center shaft, magnetic axle, or impeller blades are not broken as this will
cause the pump to fail. If your rotor assembly is broken a complete rotor assembly may be purchased at polygroupstore.com without having to replace the whole
pump. Please see Pool Support - Filtration System Troubleshooting for the SFX Filtration System at support.polygroupstore.com.
PLEASE NOTE: Even if the rotor assembly is in perfect condition if it is not seated properly between the volute cover and the pump it will not function correctly.
5. Once the rotor assembly has been checked or if replacing with a new rotor assembly, slowly insert the rotor assembly back down into the pump carefully. The
force of the magnet will pull the rotor assembly into the pump. Ensure that the rotor assembly is assembled and aligned correctly inside the pump body .
6. Once the rotor has been inserted, fasten the volute cover by screwing the volute cover lock nut .
15
OWNER’S MANUAL
Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8 AM to 5 PM Mon. thru Fri.
MST. Extended operating days and hours during peak season requirements.
ROTOR INSPECTION AND REPLACEMENT INSTRUCTIONS
2
Rotor Assembly Parts
Shaft End Cap
Washer
Impeller Fins
Magnetic Axle
Center shaft
(should be one piece going
through all parts and into
both end caps)
Washer
Shaft End Cap