Planning and installation guide

Polycom KIRK KWS300 Base Unit 

2

Prepare your Handsets and Base Unit for Installation

Before permanently installing base units, complete the following steps.

1.  Charge the batteries in the handsets so the handsets can be activated and tested.

2.  Turn on the base unit(s) and verify the power LED is light is on.

3.  Activate the base units (if not previously activated) and then activate the new handsets for each base unit following the instructions in 

the 8x8 KIRK Handset and Base Activation Guide. The guide can be found at 

http://sims.8x8.com/GetDocument.aspx?docid=710670

.

4.   Before physically installing the base units onto walls:

•  Place the base units close to their planned locations

•  Establish test calls between handsets in the areas where they will be used.

•  Verify range and sound quality.

•  Change the base location if necessary to ensure optimal call coverage and voice quality. 

Find the Best Installation Locations

1.  Avoid areas with large metal surfaces and heavy machinery that may interfere with base unit signals.

•  Keep base units at least 4 feet away from steel constructions.

•  Do not place base units directly on metallic surfaces.

•  Do not hide base units behind furniture or other physical objects.

•  Do not paint base units. Paint contains metallic/carbon particles that can affect transmission.

2.  Locate Ethernet access and either PoE or AC power outlets required to support the base units. (Note: Order KWS300 with AC Adaptor 

bundle if you do not have PoE, or simply add a standard PoE switch or standard PoE injector to power the base unit.)

3.  Verify with the end users where coverage is needed so the base unit can be placed near center of the 100-foot radius where users 

normally roam. 

Tip: 

Also identify areas where coverage is not required to simplify the installation.

4.   Consider where you might install future base units as your system grows. Note that while you can add base units later, re-assigning 

installed users to a different base unit requires more work than advance planning.

5.   Base units should be placed between 6 - 12 feet high on a wall. If placed lower, a passersby can interfere with the signal.

6.  Do NOT install units upside down or on the ceiling. Doing so decreases coverage by 40 - 50%.

7.  Ensure there is no heavy use of DECT headsets or residential DECT phone systems with individual transmitters all in the same area you are 

installing your additional DECT devices. This can cause interference and could affect performance of the base units. 

Содержание KIRK KWS300

Страница 1: ...unts with your base units when you order 3 Within the same 100 foot radius you can install up to 5 base units Example 5 base units in the same 100 foot radius support up to 20 simultaneous calls and up to 30 handsets in normal use 4 If your coverage area has a radius larger than 100 feet you can install adjacent base unit groups or cells that are 100 feet apart with up to 5 base units each Alterna...

Страница 2: ...y on metallic surfaces Do not hide base units behind furniture or other physical objects Do not paint base units Paint contains metallic carbon particles that can affect transmission 2 Locate Ethernet access and either PoE or AC power outlets required to support the base units Note Order KWS300 with AC Adaptor bundle if you do not have PoE or simply add a standard PoE switch or standard PoE inject...

Страница 3: ...vious instructions and select the optimal locations for up to 5 base units serving up to 30 handset users and the areas where they roam Ideally mount the individual base units about 2 feet apart from each other but place all near the center of the cell as in the diagram above 2 In coverage areas with multiple floors or heavy walls the base units range may be limited to 50 feet or less for the floo...

Страница 4: ...ultiple Base Units in Large Areas with a radius larger than 100 feet 100 foot cells do not overlap Cell 1 100 Ft Radius Cell 2 1 Follow the previous instructions for installing multiple base units and select the optimal locations for up to 5 base units 2 If each cell has a 100 ft radius that does not overlap with adjacent cells then each base unit can be installed and will operate independently 3 ...

Страница 5: ...lls can talk in the common overlapping area Cells on adjacent floors can also overlap 1 Follow the previous instructions for installing multiple base units and select the optimal locations for up to 5 base units 2 Where the 100 ft radius cells overlap then the maximum number of base units installed in the area that overlaps must be 5 or fewer to avoid any interference This includes where adjacent ...

Страница 6: ...to a PoE LAN Ethernet line or use a KWS300 bundle that includes a power injector In either case the Ethernet cable plugged into the base unit must be powered Note 8x8 sells the base unit for PoE deployments where the Ethernet cable used to deploy the base unit is powered or with an AC adaptor bundled where the bundle includes a PoE power injector to power the base unit If you order a base unit ord...