Spacer (S):
The spacer is used to keep at the
correct distance from the surface to be trea-
ted in order to sanitise it correctly. To fit the
spacer, insert the tip of the delivery nozzle
into the ring of the spacer, first on the side op-
posite to the fixing ring, then match the ring of
the spacer with the tip of the nozzle and fix
them together by turning the fixing ring
(Fig.7).
LACK OF WATER
When the water inside the tank is used up,
the wording “WATER EMPTY” will appear in-
termittently on the display and an acoustic si-
gnal will sound. To resume use, fill the tank
again as described un the section “Prepara-
tion for use”.
TRANSPORT
This device can be moved easily by means of
the transport grip (I) on the rear of the device
or using the two side handles. If required, the
transport grip can be removed by unscrewing
the two wing screws on the rear of the
handle.
WARNING: Never drag the device
by the nozzle. Move it only by means of
the grip (I) or the two side handles.
STORING THE DEVICE.
When you have finished using the device, put
it away in a clean and dry place after discon-
necting it from the power mains. Keep it away
from sources of heat and protect from the
weather. Do not expose the device to ex-
treme temperatures.
USING THE PRINTER
To change the paper roll, proceed as follows:
• Open the lid of the printer by pressing the
OPEN key (
D3
) (Fig.8).
• Position a paper roll inside the compart-
ment, observing the direction of rotation as
indicated (Fig.9).
• Pull the end of the paper so that it leads out
of the compartment, then close the lid
(Fig.10).
• Tear off the excess paper against the serra-
ted edge (Fig.11).
• It is possible to move the paper forward by
pressing the FEED key (
D4
).
Use thermal paper for slips, easily found on
the market. Store the paper in a dry place and
away from direct sunlight in order to ensure a
longer life both of the paper and of the data
printed on it.
INITIALISING NEW CARDS
If you purchase any new cards over and
above those supplied with the machine, they
will have to be initialized.
With the machine switched off, press keys 1
and 2 on the numerical keypad, both at the
same time. Use the switch (
A
) to turn on the
machine, then release keys 1 and 2. The indi-
cation “INITIALIZE CARD XX” will appear on
the display (XX corresponds to the number of
the card to be initialised. It is a progressive
number that cannot be repeated). Insert the
new CARD in the slot. Do not remove the
CARD until the information “CARD XX INI-
TIALIZED” appears on the display. Remove
the CARD from the slot. Once the card has
been removed, the system will prompt you to
initialize another card. To do this, follow the
instructions as above. To exit, turn of the ma-
chine using the switch (
A
). A CARD that has
already been initialised cannot be overwrit-
ten.
MAINTENANCE
Before carrying out any maintenance on
the device, always unplug it from the
power mains and allow it to cool down
before proceeding.
If the monotube is torn, it must be replaced by
an authorised service centre.
Cleaning of the delivery nozzle
Clean the delivery nozzle every 10-15 hours
of use. Clean the delivery nozzle using the
brush (
T
) included in the supply, sliding it in-
side the tube so as to remove any residues of
scaling in it (Fig.12).
SANI SYSTEM CHECK
NO MEDICALE - 1T03 ITA - EN 1T10:A5
31/10/2013
10.12
Pagina 27
Содержание SANI SYSTEM CHECK
Страница 1: ...SANI SYSTEM CHECK NO MEDICALE 1T03 ITA EN 1T10 A5 31 10 2013 10 11 Pagina 1 ...
Страница 4: ...SANI SYSTEM CHECK NO MEDICALE 1T03 ITA EN 1T10 A5 31 10 2013 10 12 Pagina 4 ...
Страница 30: ...NOTES SANI SYSTEM CHECK NO MEDICALE 1T03 ITA EN 1T10 A5 31 10 2013 10 12 Pagina 30 ...