Politec S.r.l. | Manual SADRIN – Ver. 3.3
10
7.
F.A.Q.
Barrier remains in alarm
Mare sure on both columns synchronism has been wired in
correct way and check presence of blinking LEDs on both
RX and TX;
Make sure DIPSWITCHES configuration is correct;
Make sure all expansions are well connected by flat cable;
Make sure installation has been made within max range
(especially in white colour).
Barrier gives false alarms
Make sure no animals or obstacles are interesting beams
range, in case not, if possible activate AND operation mode;
Make sure receiver column is not perpendicularly stricken
by sunrays;
Make sure voltage on terminal block is higher than 12,6
Vdc;
Use a screened cable for power, contact and syncronism
wiring, connecting screen to negative of supply to terminal
block (GND);
Install columns in “stellar” configuration avoiding “cascade”
one;
Use where possible a “linear” power supply, avoiding
switching one;
For installation distance under 1,5m remove lenses to get a
more accurate signal.